Dosimetric analysis of the use of CBCT in diagnostic radiology: sinus and middle ear.

D Dierckx1, C Saldarriaga Vargas2, F Rogge3, S Lichtherte3, L Struelens2.   

Abstract

The use of cone beam computed tomography (CBCT) in diagnostic radiology departments is increasing. Several discussions arise whether with the CBCT application, some multi-slice CT (MSCT) examinations can be replaced by it. High hopes are set regarding the dosimetric aspects of CBCT: are patient doses in between those of conventional X-rays and MSCT? In this study, effective dose and organ doses were evaluated for two non-dental CBCT examinations: sinus and middle ear. A comparison with the dose obtained with a MSCT protocol was performed. Moreover, the sinus examination was also compared with the dose obtained by projection radiography (RX). Effective doses were estimated from thermoluminescent detector dose measurements in an anthropomorphic phantom and were compared against Monte Carlo simulations. Results show that the effective dose for the sinus examination is more than three times higher with MSCT than with CBCT and about five times lower with RX compared with CBCT, whereas for the middle ear examination, the effective dose obtained with MSCT is almost six times higher than that of CBCT. Finally, a sensitivity study on the size and position of the CBCT field of view showed the influence of these two factors on the dose received by the patient.
© The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2014        PMID: 24771211     DOI: 10.1093/rpd/ncu117

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  3 in total

1.  Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT.

Authors:  Cosimo Nardi; Cinzia Talamonti; Stefania Pallotta; Paola Saletti; Linda Calistri; Cesare Cordopatri; Stefano Colagrande
Journal:  Dentomaxillofac Radiol       Date:  2017-06-20       Impact factor: 2.419

Review 2.  Radiation dose in non-dental cone beam CT applications: a systematic review.

Authors:  Cosimo Nardi; Sergio Salerno; Roberto Molteni; Mariaelena Occhipinti; Giulia Grazzini; Niccolò Norberti; Cesare Cordopatri; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-06-05       Impact factor: 3.469

3.  Cone Beam Computed Tomography-Based Anatomical Assessment of the Olfactory Fossa.

Authors:  Andre Luiz Ferreira Costa; Aline Kataki Paixão; Bianca Costa Gonçalves; Celso Massahiro Ogawa; Thiago Martinelli; Fernando Akio Maeda; Tarcila Trivino; Sérgio Lucio Pereira de Castro Lopes
Journal:  Int J Dent       Date:  2019-04-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.