Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

G Ruben H Regterschot1, Wei Zhang2, Heribert Baldus3, Martin Stevens4, Wiebren Zijlstra5.   

Abstract

This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk.
Copyright © 2014 Elsevier B.V. All rights reserved.

Keywords:  Accelerometry; Aged; Clinical assessment; Falls; Kinematics

Mesh:

Year:  2014        PMID: 24768083     DOI: 10.1016/j.gaitpost.2014.03.193

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  11 in total

1.  Can objective functional impairment in lumbar degenerative disease be reliably assessed at home using the five-repetition sit-to-stand test? A prospective study.

Authors:  Victor E Staartjes; Femke Beusekamp; Marc L Schröder
Journal:  Eur Spine J       Date:  2019-01-24       Impact factor: 3.134

2.  INTER-RATER AND TEST-RETEST RELIABILITY OF TWO NEW SINGLE LEG SIT-TO-STAND TESTS.

Authors:  Andy Waldhelm; Coral Gubler; Katie Sullivan; Chris Witte; Devin Buchheister; Jacob Bartz-Broussard
Journal:  Int J Sports Phys Ther       Date:  2020-05

3.  Toward Remote Assessment of Physical Frailty Using Sensor-based Sit-to-stand Test.

Authors:  Catherine Park; Amir Sharafkhaneh; Mon S Bryant; Christina Nguyen; Ilse Torres; Bijan Najafi
Journal:  J Surg Res       Date:  2021-02-27       Impact factor: 2.417

4.  Test-retest reliability of a pendant-worn sensor device in measuring chair rise performance in older persons.

Authors:  Wei Zhang; G Ruben H Regterschot; Hana Schaabova; Heribert Baldus; Wiebren Zijlstra
Journal:  Sensors (Basel)       Date:  2014-05-16       Impact factor: 3.576

Review 5.  The application of strength and power related field tests in older adults: criteria, current status and a future perspective.

Authors:  G Ruben H Regterschot; Tobias Morat; Marjanne Folkersma; Wiebren Zijlstra
Journal:  Eur Rev Aging Phys Act       Date:  2015-10-07       Impact factor: 3.878

6.  A Home-Based Exercise Program Driven by Tablet Application and Mobility Monitoring for Frail Older Adults: Feasibility and Practical Implications.

Authors:  Hilde A E Geraedts; Wiebren Zijlstra; Wei Zhang; Sophie L W Spoorenberg; Marcos Báez; Iman Khaghani Far; Heribert Baldus; Martin Stevens
Journal:  Prev Chronic Dis       Date:  2017-02-02       Impact factor: 2.830

7.  Data Quality and Reliability Assessment of Wearable EMG and IMU Sensor for Construction Activity Recognition.

Authors:  Srikanth Sagar Bangaru; Chao Wang; Fereydoun Aghazadeh
Journal:  Sensors (Basel)       Date:  2020-09-15       Impact factor: 3.576

8.  Test-Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults.

Authors:  Daniel Jerez-Mayorga; Álvaro Huerta-Ojeda; Luis Javier Chirosa-Ríos; Francisco Guede-Rojas; Iris Paola Guzmán-Guzmán; Leonardo Intelangelo; Claudia Miranda-Fuentes; Pedro Delgado-Floody
Journal:  Int J Environ Res Public Health       Date:  2021-06-25       Impact factor: 3.390

9.  Reliability, measurement error and minimum detectable change in mobility measures: a cohort study of community-dwelling adults aged 50 years and over in Ireland.

Authors:  Orna A Donoghue; George M Savva; Axel Börsch-Supan; Rose Anne Kenny
Journal:  BMJ Open       Date:  2019-11-11       Impact factor: 2.692

10.  Sit-To-Stand Movement Evaluated Using an Inertial Measurement Unit Embedded in Smart Glasses-A Validation Study.

Authors:  Justine Hellec; Frédéric Chorin; Andrea Castagnetti; Serge S Colson
Journal:  Sensors (Basel)       Date:  2020-09-04       Impact factor: 3.576