Repeatability of lens densitometry using Scheimpflug imaging.

Xenia Weiner1, Martin Baumeister1, Thomas Kohnen1, Jens Bühren2.   

Abstract

PURPOSE: To evaluate the repeatability of different lens densitometry analysis modes performed with Scheimpflug imaging using the Pentacam HR device.
SETTING: University eye hospital, Frankfurt am Main, Germany.
DESIGN: Cross-sectional study.
METHODS: Eyes were analyzed under mydriasis during 2 examinations performed by the same examiner. Three single measurements were taken to assess lens densitometry via 3 modes as follows: peak (maximum), linear (vertical axis), and 3-dimensional (3-D). Measurements were also taken using 3 cylindrical reference blocks (P) with different diameters (2.0 mm, 4.0 mm, 6.00 mm) composing the whole lens depth. Repeatability was tested using Bland-Altman analysis. As statistical parameters, the coefficient of repeatability (CoR) and the relative repeatability (RR) were applied.
RESULTS: The study analyzed 105 eyes. The CoR of the peak modus was 5.6 (RR, 29.8%); of the linear modus, 0.9 (RR, 8.8%); and of the 3-D modus, 0.36 (RR, 3.6%). The values of the P mode were lower, with a CoR between 0.19 and 0.30 (RR, 2.1%-3.3%).
CONCLUSIONS: Lens densitometry using Scheimpflug imaging was highly repeatable. However, repeatability was dependent on the analysis mode used. Repeatability decreased with increasing opacification.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24767909     DOI: 10.1016/j.jcrs.2013.10.039

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

2.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

3.  The iridocorneal angle and related anterior segment structures in pediatric anisohyperopic amblyopic eyes.

Authors:  Müjdat Karabulut; Sinem Karabulut; Hüseyin Cem Simsek; Aylin Karalezli
Journal:  SAGE Open Med       Date:  2022-06-29

4.  Objective evaluation of changes in lens clarity after repeated injections of ranibizumab in patients with neovascular age-related macular degeneration.

Authors:  Orhan Altunel; Saadet Gültekin Irgat; Fatih Özcura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-04-21       Impact factor: 3.535

5.  The quantitative assessment of alterations in lens transparency after transconjunctival 27-gauge microincision vitrectomy surgery.

Authors:  K Tekin; M Inanc; K Ozdemir; K Sonmez; P Yilmazbas
Journal:  Eye (Lond)       Date:  2017-10-27       Impact factor: 3.775

6.  Assessment of cataract forming effect of diabetes in young adults by lens densitometer.

Authors:  Neslihan Bayraktar Bilen; Murat Sinan Sarıcaoğlu
Journal:  Int Ophthalmol       Date:  2020-10-28       Impact factor: 2.031

7.  Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction.

Authors:  Fernando Faria-Correia; Bernardo T Lopes; Isaac C Ramos; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Clin Ophthalmol       Date:  2016-04-06

8.  Preclinical cataract masquerading as post-LASIK regression.

Authors:  Rohit Shetty; Nikhil Negalur; Mathew Kurian; Rushad Shroff
Journal:  Oman J Ophthalmol       Date:  2016 Sep-Dec

9.  Femtosecond laser combined with non-chopping rotation phacoemulsification technique for soft-nucleus cataract surgery: a prospective study.

Authors:  Hui Chen; Haotian Lin; Wan Chen; Bo Zhang; Wu Xiang; Jing Li; Weirong Chen; Yizhi Liu
Journal:  Sci Rep       Date:  2016-01-05       Impact factor: 4.379

10.  Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.

Authors:  Ireneusz Grulkowski; Silvestre Manzanera; Lukasz Cwiklinski; Juan Mompeán; Alberto de Castro; Jose Maria Marin; Pablo Artal
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.