Literature DB >> 24764331

Inter-rater reliability and measurement error of sonographic muscle architecture assessments.

Niklas König1, Michael Cassel, Konstantina Intziegianni, Frank Mayer.   

Abstract

OBJECTIVES: Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation.
METHODS: The medial gastrocnemius muscle of 15 healthy participants was measured with sagittal B-mode ultrasound scans. The muscle thickness, fascicle length, superior pennation angle, and inferior pennation angle were assessed. The participants were examined by 2 investigators. A custom-made foam cast was used for standardized positioning of the probe. To analyze inter-rater reliability, the examinations of both raters were compared. The impact of probe positioning was assessed by comparison of foam cast and freehand scans. Error arising from picture interpretation was assessed by comparing the investigators' analyses of foam cast scans independently. Reliability was expressed as the intraclass correlation coefficient (ICC), inter-rater variability (IRV), Bland-Altman analysis (bias ± limits of agreement [LoA]), and standard error of measurement (SEM).
RESULTS: Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias ± LoA, 0.2 ± 0.2-1.7 ± 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0° ± 2.2° to 3.4° ± 4.1°. The highest IRV was found for muscle thickness (13.4%). When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm.
CONCLUSIONS: Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.

Entities:  

Keywords:  gastrocnemius muscle; inter-rater variability; muscle architecture; musculoskeletal ultrasound; sonography

Mesh:

Year:  2014        PMID: 24764331     DOI: 10.7863/ultra.33.5.769

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  12 in total

Review 1.  Morphological and functional relationships with ultrasound measured muscle thickness of the lower extremity: a brief review.

Authors:  Takashi Abe; Jeremy P Loenneke; Robert S Thiebaud
Journal:  Ultrasound       Date:  2015-05-29

2.  Sonographic morphometry of abductor pollicis brevis: can direct contact yield images comparable with those obtained by the water bath technique?

Authors:  Keitaro Fujino; Katsunori Ohno; Kenta Fujiwara; Atsushi Yokota; Masashi Neo
Journal:  J Med Ultrason (2001)       Date:  2019-04-15       Impact factor: 1.314

3.  Assessing the Reliability of Handheld Dynamometry and Ultrasonography to Measure Quadriceps Strength and Muscle Thickness in Children, Adolescents, and Young Adults.

Authors:  Kelly Rock; Christa Nelson; Odessa Addison; Victoria Marchese
Journal:  Phys Occup Ther Pediatr       Date:  2021-02-09       Impact factor: 2.297

4.  Within- and between-session reliability of medial gastrocnemius architectural properties.

Authors:  J J McMahon; A Turner; P Comfort
Journal:  Biol Sport       Date:  2016-04-27       Impact factor: 2.806

5.  Information from dynamic length changes improves reliability of static ultrasound fascicle length measurements.

Authors:  Jeroen Aeles; Glen A Lichtwark; Sietske Lenchant; Liesbeth Vanlommel; Tijs Delabastita; Benedicte Vanwanseele
Journal:  PeerJ       Date:  2017-12-15       Impact factor: 2.984

6.  Tensiomyography Derived Parameters Reflect Skeletal Muscle Architectural Adaptations Following 6-Weeks of Lower Body Resistance Training.

Authors:  Matthew T Wilson; Andrew M F Ryan; Scott R Vallance; Alastair Dias-Dougan; James H Dugdale; Angus M Hunter; D Lee Hamilton; Lewis J Macgregor
Journal:  Front Physiol       Date:  2019-12-10       Impact factor: 4.566

7.  Ultrasound Measurement of the Transverse Abdominis, Internal Oblique, and External Oblique Muscles Associated with Forward Head Posture and Reduced Cranio-Vertebral Angle.

Authors:  Kyung Woo Kang; Yong Hyun Kwon; Sung Min Son
Journal:  Med Sci Monit       Date:  2021-06-07

8.  Simple Muscle Architecture Analysis (SMA): An ImageJ macro tool to automate measurements in B-mode ultrasound scans.

Authors:  Olivier R Seynnes; Neil J Cronin
Journal:  PLoS One       Date:  2020-02-12       Impact factor: 3.240

9.  Validity and reliability of velocity measurements on ultrasonography using custom software with an optical-flow algorithm.

Authors:  Tomoko Yamashita; Kohei Ozawa; Kazuyoshi Gamada
Journal:  J Phys Ther Sci       Date:  2020-02-14

10.  Gastrocnemius Muscle Architecture in Elite Basketballers and Cyclists: A Cross-Sectional Cohort Study.

Authors:  Samantha May; Simon Locke; Michael Kingsley
Journal:  Front Sports Act Living       Date:  2021-12-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.