Literature DB >> 24760179

Arterial contour detectability in head CT angiography.

Yukihiro Enchi1, Kuniharu Imai, Mitsuru Ikeda, Ikuko Takase, Chiyo Yamauchi-Kawaura, Masaki Mori.   

Abstract

PURPOSE: Arterial contour extraction is essential for visualization and analysis of vasculature in CT angiography (CTA). A means for evaluating the detectability of artery contours CTA images is required. We developed and tested a new method for this purpose based on phase information from two-dimensional Fourier transforms of CTA images. The relationship between arterial contour detectability and a patient's ocular lens dose was evaluated in CTA images obtained with various tube voltages and currents.
METHODS: A head phantom was designed for use as a target object containing a simulated vascular tree, filled with dilute contrast medium (10 mg iodine/ml). The head phantom was scanned using a 64-multidetector CT scanner with tube voltages of 80-140 kV and tube currents corresponding to volume CT dose index [Formula: see text] ranging from 24.4 to 72.8 mGy. Lens doses were measured using the planar silicon PIN-photodiode system. The quality of artery contours in the CTA source images was assessed using a computed detectability index.
RESULTS: Lens dose increased proportionally with tube voltage and current. The use of 80 kV provided the highest contour detectability. However, for each tube voltage, the detectability of artery contours was almost constant across the CTDI(vol) values. These results were mostly consistent with the subjective recognition of artery contours on CTA images.
CONCLUSIONS: A CTA protocol using 80 kV and 420 mA can reduce the radiation exposure to ocular lens by approximately 40 %, and improve the artery contour detectability compared with a routine protocol.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24760179     DOI: 10.1007/s11548-014-0999-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  17 in total

1.  Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.

Authors:  Yoshiko Sagara; Amy K Hara; William Pavlicek; Alvin C Silva; Robert G Paden; Qing Wu
Journal:  AJR Am J Roentgenol       Date:  2010-09       Impact factor: 3.959

2.  Analysis of streak artefacts on CT images using statistics of extremes.

Authors:  K Imai; M Ikeda; S Wada; Y Enchi; T Niimi
Journal:  Br J Radiol       Date:  2007-11       Impact factor: 3.039

3.  Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose.

Authors:  S Suzuki; S Furui; T Ishitake; T Abe; H Machida; R Takei; K Ibukuro; A Watanabe; T Kidouchi; Y Nakano
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-31       Impact factor: 3.825

4.  Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis.

Authors:  H J Cloft; G J Joseph; J E Dion
Journal:  Stroke       Date:  1999-02       Impact factor: 7.914

5.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

6.  Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to "triage" patients' treatment.

Authors:  R Agid; S K Lee; R A Willinsky; R I Farb; K G terBrugge
Journal:  Neuroradiology       Date:  2006-09-29       Impact factor: 2.804

7.  Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality.

Authors:  Walter Huda; Kristin A Lieberman; Jack Chang; Marsha L Roskopf
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

Review 8.  Subarachnoid hemorrhage without detectable aneurysm. A review of the causes.

Authors:  G J Rinkel; J van Gijn; E F Wijdicks
Journal:  Stroke       Date:  1993-09       Impact factor: 7.914

9.  Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography.

Authors:  A M McKinney; C S Palmer; C L Truwit; A Karagulle; M Teksam
Journal:  AJNR Am J Neuroradiol       Date:  2007-12-07       Impact factor: 3.825

10.  CT angiography with three-dimensional techniques for the early diagnosis of intracranial aneurysms. Comparison with intra-arterial DSA and the surgical findings.

Authors:  Maria T Karamessini; George C Kagadis; Theodore Petsas; Dimitrios Karnabatidis; Dimitrios Konstantinou; George C Sakellaropoulos; George C Nikiforidis; Dimitrios Siablis
Journal:  Eur J Radiol       Date:  2004-03       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.