Literature DB >> 24753085

Robust myocardial T2 and T2 * mapping at 3T using image-based shimming.

Arshad Zaman1, David M Higgins, Manish Motwani, Ananth Kidambi, Marc Kouwenhoven, Sebastian Kozerke, John P Greenwood, Sven Plein.   

Abstract

PURPOSE: Intramyocardial hemorrhage and area at risk are both prognostic markers in acute myocardial infarction (AMI). Myocardial T2 and T2 * mapping have been used to detect such tissue changes at 1.5T but these techniques are challenging at 3.0T due to additional susceptibility variation. We studied T2 and T2 * myocardial mapping techniques at 3.0T on a system employing B1 shimming and compared two different methods of B0 shimming.
MATERIALS AND METHODS: Fifteen volunteers and six AMI patients were scanned on a 3T system. Volume and image-based (IB) B0 shimming techniques were implemented. Single breath-hold, multiecho gradient, and spin echo sequences were employed from which T2 * and T2 maps were calculated.
RESULTS: In volunteers, there was no significant difference in mean values obtained with volume or IB shimming for T2 mapping (39.1 ± 6.0 msec vs. 39.4 ± 6.1 msec; P > 0.05) or for T2 * mapping (24.2 ± 6.7 msec vs. 24.1 ± 5.2 msec; P > 0.05). There were no significant regional differences in mean T2 values between septal, anterior, and posterior segments with either shimming technique (all P > 0.05); but there were significant regional differences in mean T2 * values using volume shimming (27.8 ± 5.2 msec vs. 28.4 ± 5.8 msec vs. 15.9 ± 8.3 msec; P < 0.05)-but not with IB shimming (25.7 ± 5.4 msec vs. 25.3 ± 5.9 msec vs. 18.7 ± 4.6 msec; P > 0.05).
CONCLUSION: At 3.0T, cardiac T2 mapping is robust. Although T2 * mapping is prone to more regional heterogeneity this can be reduced by using IB instead of conventional volume B0 shimming.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  acute myocardial infarction; image-based shimming; myocardial T2 and T2* mapping

Mesh:

Year:  2014        PMID: 24753085     DOI: 10.1002/jmri.24636

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

2.  Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial infarction at 3 Tesla.

Authors:  Ananth Kidambi; John D Biglands; David M Higgins; David P Ripley; Arshad Zaman; David A Broadbent; Adam K McDiarmid; Peter P Swoboda; Tarique Al Musa; Bara Erhayiem; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2014-10-28       Impact factor: 5.364

3.  Free-breathing simultaneous T 1 , T 2 , and T 2 quantification in the myocardium.

Authors:  Ingo Hermann; Peter Kellman; Omer B Demirel; Mehmet Akçakaya; Lothar R Schad; Sebastian Weingärtner
Journal:  Magn Reson Med       Date:  2021-03-29       Impact factor: 4.668

4.  Diagnostic performance of T1 and T2 mapping to detect intramyocardial hemorrhage in reperfused ST-segment elevation myocardial infarction (STEMI) patients.

Authors:  Heerajnarain Bulluck; Stefania Rosmini; Amna Abdel-Gadir; Anish N Bhuva; Thomas A Treibel; Marianna Fontana; Esther Gonzalez-Lopez; Manish Ramlall; Ashraf Hamarneh; Alex Sirker; Anna S Herrey; Charlotte Manisty; Derek M Yellon; James C Moon; Derek J Hausenloy
Journal:  J Magn Reson Imaging       Date:  2017-02-15       Impact factor: 4.813

5.  T2 relaxation time for the early prediction of treatment response to chemoradiation in locally advanced rectal cancer.

Authors:  Yuxi Ge; Yanlong Jia; Xiaohong Li; Weiqiang Dou; Zhong Chen; Gen Yan
Journal:  Insights Imaging       Date:  2022-07-07

6.  Detection of Intramyocardial Iron in Patients Following ST-Elevation Myocardial Infarction Using Cardiac Diffusion Tensor Imaging.

Authors:  Arka Das; Christopher Kelly; Irvin Teh; Noor Sharrack; Christian T Stoeck; Sebastian Kozerke; Jürgen E Schneider; Sven Plein; Erica Dall'Armellina
Journal:  J Magn Reson Imaging       Date:  2022-01-12       Impact factor: 5.119

7.  Cardiovascular magnetic resonance native T2 and T2* quantitative values for cardiomyopathies and heart transplantations: a systematic review and meta-analysis.

Authors:  G J H Snel; M van den Boomen; L M Hernandez; C T Nguyen; D E Sosnovik; B K Velthuis; R H J A Slart; R J H Borra; N H J Prakken
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-11       Impact factor: 5.364

8.  Cardiac T2 mapping: robustness and homogeneity of standardized in-line analysis.

Authors:  Marco Wiesmueller; Wolfgang Wuest; Rafael Heiss; Christoph Treutlein; Michael Uder; Matthias Stefan May
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-28       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.