Improved contrast and spatial resolution with Single Photon Counting (SPC) for an area x-ray imager, the newly developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector.

Amit Jain1, Andrew Kuhls-Gilcrist2, Daniel R Bednarek3, Stephen Rudin4.   

Abstract

Although in radiological imaging, the prevailing mode of acquisition is the integration of the energy deposited by all x-rays absorbed in the imaging detector, much improvement in image spatial and contrast resolution could be achieved if each individual x-ray photon were detected and counted separately. In this work we compare the conventional energy integration (EI) mode with the new single photon counting (SPC) mode for a recently developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector, which is uniquely capable of both modes of operation. The MAF has 1024×1024 pixels of 35 microns effective size and is capable of real-time imaging at 30 fps. The large variable gain of its light image intensifier (LII) provides quantum limited operation with essentially no additive instrumentation noise and enables the MAF to operate in both EI and the very sensitive low-exposure SPC modes. We used high LII gain with very low exposure (<1 x-ray photon/pixel) per frame for SPC mode and higher exposure per frame with lower gain for EI mode. Multiple signal-thresholded frames were summed in SPC mode to provide an integrated frame with the same total exposure as EI mode. A heavily K-edge filtered x-ray beam (average energy of 31 keV) was used to provide a nearly monochromatic spectrum. The MTF measured using a standard slit method showed a dramatic improvement for the SPC mode over the EI mode at all frequencies. Images of a line pair phantom also showed improved spatial resolution with 12 lp/mm visible in SPC mode compared to only 8 lp/mm in EI mode. In SPC mode, images of human distal and middle phalanges showed the trabecular structures of the bone with far better contrast and detail. These improvements with the SPC mode should be advantageous for clinical applications where high resolution and/or high contrast are essential such as in mammography and extremity imaging as well as for dual modality applications, which combine nuclear medicine and x-ray imaging using a single detector.

Entities:  

Year:  2009        PMID: 24748764      PMCID: PMC3991167          DOI: 10.1109/NSSMIC.2009.5401587

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  5 in total

1.  Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution.

Authors:  Freek J Beekman; Gerralt A de Vree
Journal:  Phys Med Biol       Date:  2005-05-25       Impact factor: 3.609

2.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

3.  A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems.

Authors:  G K Yadava; A T Kuhls-Gilcrist; S Rudin; V K Patel; K R Hoffmann; D R Bednarek
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

4.  Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Authors:  C N Ionita; C Keleshis; V Patel; G Yadava; K R Hoffmann; D R Bednarek; A Jain; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

5.  Photon-counting gamma camera based on columnar CsI(Tl) optically coupled to a back-illuminated CCD.

Authors:  Brian W Miller; H Bradford Barber; Harrison H Barrett; Liying Chen; Sean J Taylor
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007-01-01
  5 in total
  2 in total

1.  High Resolution Emission and Transmission Imaging Using the Same Detector.

Authors:  Ashish S Panse; A Jain; W Wang; R Yao; D R Bednarek; S Rudin
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

2.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.