Literature DB >> 24748038

Percutaneous angioplasty used to manage native and recurrent coarctation of the aorta in infants younger than 1 year: immediate and midterm results.

Philippe Mahouna Adjagba1, Baher Hanna, Joaquim Miró, Adrian Dancea, Nancy Poirier, Suzanne Vobecky, Julie Déry, Chantale Lapierre, Nagib Dahdah.   

Abstract

Balloon angioplasty (BAP) used to manage native coarctation of the aorta (CoAo) in infants remains controversial. This study aimed to compare short- and midterm results of BAP between native CoAo (NaCo) and postsurgical recoarctations (ReCo) in infants younger than 1 year. This retrospective study compared the clinical, echocardiographic, hemodynamic, and angiographic data for infants who underwent BAP between July 2003 and September 2012. The 12 NaCo and 13 ReCo patients in this study underwent BAP at 4.61 ± 3.69 and 4.88 ± 3.07 months (p = 0.84) and weighed 5.49 ± 2.57 and 6.10 ± 2.11 kg (p = 0.52), respectively. Their respective heights were 60.58 ± 10.58 and 61.15 ± 6.74 cm (p = 0.87). All the ReCo patients had their initial surgery before the age of 3 months. The minimal CoAo diameter was 2.81 ± 0.96 mm in the NaCo group and 2.86 ± 1.0 mm in the ReCo group (p = 0.90). The relative gradient reduction was 62.79 ± 32.43 % in the NaCo group and 73.37 ± 20.78 % in the ReCo group (p = 0.33). The in situ complication rate (pseudoaneurysm) was 8.33 % in the NaCo group and 7.69 % in the ReCo group (p = 0.74). During the early follow-up evaluation, five NaCo patients (41.66 %) presented with recoarctation requiring BAP reintervention within 1.75 ± 1.41 months (all had their initial BAP before 3 months of age) compared with 1 ReCo patient (7.69 %) (p = 0.165). The mean follow-up period was 3.09 ± 2.69 years for the NaCo patients and 3.6 ± 3.18 years for the ReCo patients (p = 0.69), during which the blood pressure gradient was 12.33 ± 9.67 for the NaCo patients and 7.80 ± 8.78 for the ReCo patients (p = 0.17), with corresponding Doppler peak instantaneous gradients of 21.29 ± 11.19 and 16.20 ± 10.23 (p = 0.24). The resultant diameter ratio between the minimal isthmus diameter and the aortic diameter at the diaphragmatic level was 0.81 ± 0.15 in the NaCo group and 0.85 ± 0.12 in the ReCo group (p = 0.53). The immediate and midterm results of BAP for the NaCo and ReCo infants were comparable. Accordingly, BAP seems to be an acceptable alternative to surgery for infants older than 3 months.

Entities:  

Mesh:

Year:  2014        PMID: 24748038     DOI: 10.1007/s00246-014-0909-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  23 in total

1.  Extended resection and end-to-end anastomosis for aortic coarctation in infants: results of a tailored surgical approach.

Authors:  Gail E Wright; Cheryl A Nowak; Caren S Goldberg; Richard G Ohye; Edward L Bove; Albert P Rocchini
Journal:  Ann Thorac Surg       Date:  2005-10       Impact factor: 4.330

2.  [Balloon angioplasty for native coarctation in children: immediate and medium-term results].

Authors:  María J del Cerro; Aurora Fernández-Ruiz; Fernando Benito; Dolores Rubio; María C Castro; Felipe Moreno
Journal:  Rev Esp Cardiol       Date:  2005-09       Impact factor: 4.753

3.  Acute results of balloon angioplasty of native coarctation versus recurrent aortic obstruction are equivalent. Valvuloplasty and Angioplasty of Congenital Anomalies (VACA) Registry Investigators.

Authors:  B W McCrindle; T K Jones; W R Morrow; D J Hagler; T R Lloyd; S Nouri; L A Latson
Journal:  J Am Coll Cardiol       Date:  1996-12       Impact factor: 24.094

4.  Isolated aortic coarctation in neonates and infants: results of resection and end-to-end anastomosis.

Authors:  J P Pfammatter; G Ziemer; R Kaulitz; M K Heinemann; I Luhmer; H C Kallfelz
Journal:  Ann Thorac Surg       Date:  1996-09       Impact factor: 4.330

5.  Comparison of surgical repair with balloon angioplasty for native coarctation in patients from 3 months to 16 years of age.

Authors:  Ronald J Walhout; Jaco C Lekkerkerker; Gordon H Oron; Ger B W E Bennink; Erik J Meijboom
Journal:  Eur J Cardiothorac Surg       Date:  2004-05       Impact factor: 4.191

6.  Balloon angioplasty of native coarctation and comparison of patients younger and older than 3 months.

Authors:  Cheng-Liang Lee; Jeng-Feng Lin; Kai-Sheng Hsieh; Chu-Chung Lin; Ta-Cheng Huang
Journal:  Circ J       Date:  2007-11       Impact factor: 2.993

7.  Aortic aneurysm after patch aortoplasty repair of coarctation: a prospective analysis of prevalence, screening tests and risks.

Authors:  B I Bromberg; R H Beekman; A P Rocchini; A R Snider; E R Bank; K Heidelberger; A Rosenthal
Journal:  J Am Coll Cardiol       Date:  1989-09       Impact factor: 24.094

8.  Balloon angioplasty of native coarctation of the aorta in a local group of children: acute results and midterm angiographic re-assessment.

Authors:  S C Brown; A D Bruwer
Journal:  Cardiovasc J S Afr       Date:  2003 Jul-Aug

9.  [Balloon angioplasty for native aortic coarctation in children younger than 12 months: immediate and medium-term results].

Authors:  José Rafael Parra-Bravo; Martín Reséndiz-Balderas; Ramona Francisco-Candelario; Heladia García; Miguel Alejandro Chávez-Fernández; Luisa G Beirana-Palencia; José Luis Acosta-Valdez; María de Jesús Estrada-Loza; José Vicente Estrada Flores
Journal:  Arch Cardiol Mex       Date:  2007 Jul-Sep

10.  Balloon angioplasty of native coarctation of the aorta: midterm follow-up and prognostic factors.

Authors:  S E Fletcher; M R Nihill; R G Grifka; M P O'Laughlin; C E Mullins
Journal:  J Am Coll Cardiol       Date:  1995-03-01       Impact factor: 24.094

View more
  5 in total

Review 1.  The Challenges of Redo Aortic Coarctation Repair in Adults.

Authors:  Jonathan D Price; Damien J LaPar
Journal:  Curr Cardiol Rep       Date:  2019-07-27       Impact factor: 2.931

2.  A comparison of balloon angioplasty of native coarctation versus surgical repair for short segment coarctation associated with ventricular septal defect-a single-center retrospective review of 92 cases.

Authors:  Huifeng Zhang; Ming Ye; Gang Chen; Fang Liu; Lin Wu; Bing Jia
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

3.  Self-Expandable Stents in Vascular Stenosis of Moderate to Large-Sized Vessels in Congenital Heart Disease: Early and Intermediate-Term Results.

Authors:  Gi Young Jang; Kee Soo Ha
Journal:  Korean Circ J       Date:  2019-05-29       Impact factor: 3.243

4.  The efficacy and safety of percutaneous balloon angioplasty for aortic coarctation in children. Acute and mid-term results in a single center experience.

Authors:  Saad Q Khoshhal; Mansour B Al-Mutairi; Abdulhameed A Alnajjar; Mohamed M Morsy; Sherif Salem; Aseel A Salmi; Khaled M El-Harbi; Hany M Abo-Haded
Journal:  Saudi Med J       Date:  2020-11       Impact factor: 1.484

5.  Multi-centre cross-sectional study on vascular remodelling in children following successful coarctation correction.

Authors:  Skaiste Sendzikaite; Rita Sudikiene; Inguna Lubaua; Pauls Silis; Agata Rybak; Grazyna Brzezinska-Rajszys; Łukasz Obrycki; Augustina Jankauskiene; Mieczysław Litwin
Journal:  J Hum Hypertens       Date:  2021-08-03       Impact factor: 2.877

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.