Literature DB >> 16185618

[Balloon angioplasty for native coarctation in children: immediate and medium-term results].

María J del Cerro1, Aurora Fernández-Ruiz, Fernando Benito, Dolores Rubio, María C Castro, Felipe Moreno.   

Abstract

INTRODUCTION AND
OBJECTIVES: The use of balloon angioplasty to treat native aortic coarctation in pediatric patients is controversial. Our aims were to report our experience with this technique and to compare retrospectively the immediate and medium-term results obtained during 2 distinct time periods. SUBJECTS AND
METHOD: 53 patients who underwent balloon angioplasty for native coarctation were divided into 2 groups: (A) those treated between 1985-1988 (n=26); and (B) those treated between 1993-2003 (n=27). Follow-up data were available for all patients.
RESULTS: The immediate result was good (i.e., pressure gradient, <20 mmHg) in 18/26 patients in group A (69.2%) and 22/27 (81.5%) in group B. On follow-up, the recoarctation rate was similar in both groups: 33% in group A and 25.6% in group B. Group A patients with recoarctation were referred for surgery, whereas group B patients underwent a second angioplasty (either balloon or stent). At the end of follow-up, angioplasty had been successful in 62% (16/26) of patients in group A vs 85% (23/27) in group B. The incidence of serious complications was lower in group B (4%) than group A (19.2%), as was the incidence of aneurysm: 4% in group B vs 15% in group A.
CONCLUSIONS: Balloon angioplasty is an effective alternative to surgery for the treatment of native, localized aortic coarctation. Better selection of suitable patients, use of low-profile catheters, and improved patient care can reduce the incidence of complications. Repeat angioplasty (either balloon or stent) in cases of recoarctation has improved results with this technique.

Entities:  

Mesh:

Year:  2005        PMID: 16185618

Source DB:  PubMed          Journal:  Rev Esp Cardiol        ISSN: 0300-8932            Impact factor:   4.753


  2 in total

1.  Endovascular stent implantation for aortic coarctation: parameters affecting clinical outcomes.

Authors:  Ibrahim Hatoum; Raymond N Haddad; Zakhia Saliba; Toni Abdel Massih
Journal:  Am J Cardiovasc Dis       Date:  2020-12-15

2.  Percutaneous angioplasty used to manage native and recurrent coarctation of the aorta in infants younger than 1 year: immediate and midterm results.

Authors:  Philippe Mahouna Adjagba; Baher Hanna; Joaquim Miró; Adrian Dancea; Nancy Poirier; Suzanne Vobecky; Julie Déry; Chantale Lapierre; Nagib Dahdah
Journal:  Pediatr Cardiol       Date:  2014-04-20       Impact factor: 1.655

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.