Literature DB >> 24746019

Geometry-based pressure drop prediction in mildly diseased human coronary arteries.

J T C Schrauwen1, J J Wentzel2, A F W van der Steen2, F J H Gijsen2.   

Abstract

Pressure drop (△p) estimations in human coronary arteries have several important applications, including determination of appropriate boundary conditions for CFD and estimation of fractional flow reserve (FFR). In this study a △p prediction was made based on geometrical features derived from patient-specific imaging data. Twenty-two mildly diseased human coronary arteries were imaged with computed tomography and intravascular ultrasound. Each artery was modelled in three consecutive steps: from straight to tapered, to stenosed, to curved model. CFD was performed to compute the additional △p in each model under steady flow for a wide range of Reynolds numbers. The correlations between the added geometrical complexity and additional △p were used to compute a predicted △p. This predicted △p based on geometry was compared to CFD results. The mean △p calculated with CFD was 855±666Pa. Tapering and curvature added significantly to the total △p, accounting for 31.4±19.0% and 18.0±10.9% respectively at Re=250. Using tapering angle, maximum area stenosis and angularity of the centerline, we were able to generate a good estimate for the predicted △p with a low mean but high standard deviation: average error of 41.1±287.8Pa at Re=250. Furthermore, the predicted △p was used to accurately estimate FFR (r=0.93). The effect of the geometric features was determined and the pressure drop in mildly diseased human coronary arteries was predicted quickly based solely on geometry. This pressure drop estimation could serve as a boundary condition in CFD to model the impact of distal epicardial vessels.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Atherosclerosis; CFD; Coronary arteries; FFR; Pressure drop prediction

Mesh:

Year:  2014        PMID: 24746019     DOI: 10.1016/j.jbiomech.2014.03.028

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Reduced order models for transstenotic pressure drop in the coronary arteries.

Authors:  Mehran Mirramezani; Scott Diamond; Harold Litt; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2018-12-05       Impact factor: 2.097

2.  Automated generation of 0D and 1D reduced-order models of patient-specific blood flow.

Authors:  Martin R Pfaller; Jonathan Pham; Aekaansh Verma; Luca Pegolotti; Nathan M Wilson; David W Parker; Weiguang Yang; Alison L Marsden
Journal:  Int J Numer Method Biomed Eng       Date:  2022-08-14       Impact factor: 2.648

3.  Effect of guidewire insertion in fractional flow reserve procedure for real geometry using computational fluid dynamics.

Authors:  Yasser Abuouf; Muhamed AlBadawi; Shinichi Ookawara; Mahmoud Ahmed
Journal:  Biomed Eng Online       Date:  2021-09-28       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.