| Literature DB >> 24741446 |
Zeki Dostbil1, Yusuf Dag2, Ozlem Cetinkaya1, Mehmet Akdag3, Bekir Tasdemir1.
Abstract
Objectives. The measurement of mucociliary transport velocity by rhinoscintigraphy with Tc-99m-macroaggregated albumin ((99m)Tc-MAA) is reliable measure of mucociliary clearance. The aim of this study is to assess the intratest, interobserver, and intraobserver reproducibility of nasal mucociliary transport rate (NMTR) measurement. Materials and Methods. Twenty-two subjects were evaluated to determine intratest reproducibility and a group of 35 subjects was examined to determine inter- and intraobserver reproducibility. Rhinoscintigraphy with (99m)Tc-MAA was used to measure NMTR in all study subjects. Paired NMTR measurements were compared using a range of statistical methodologies. Intraclass correlation coefficients (ICC) and repeatability coefficients and Bland-Altman plots were applied to assess the degree of intratest, interobserver, and intraobserver variation. Results. Statistical analysis of test and retest experiments demonstrated the statistical equivalence of intratest NMTR measurements, interobserver NMTR measurements, and intraobserver NMTR measurements. The intratest ICC, interobserver ICC, and intraobserver ICC were 0.96, 0.83, and 0.91, respectively, indicating that intratest and intraobserver reproducibility are excellent and interobserver reproducibility is good. Conclusions. Rhinoscintigraphy using (99m)Tc-MAA results in highly reproducible measurement of NMTR. The use of radionuclide imaging in measuring NMTR results in excellent intratest and intraobserver reproducibility and good interobserver reliability.Entities:
Year: 2014 PMID: 24741446 PMCID: PMC3967819 DOI: 10.1155/2014/982515
Source DB: PubMed Journal: Scientifica (Cairo) ISSN: 2090-908X
Nasal mucociliary transport rates measured for intratest, interobserver, and intraobserver reproducibility and statistical comparison.
| Type of reliability | NMTR (mm/min) |
| |
|---|---|---|---|
| Mean ± SD | Range | ||
| Intratest ( | |||
| 1st scan | 8 ± 3.4 | 2–12.4 | 0.338 |
| 2nd scan | 7.9 ± 3.3 | 1.9–13.2 | |
| Interobserver ( | |||
| Observer 1 | 6.8 ± 3.3 | 1.5–12.4 | 0.211 |
| Observer 2 | 7.2 ± 3.7 | 1.4–13.5 | |
| Intraobserver ( | |||
| 1st measurement | 6.8 ± 3.3 | 1.5–12.4 | 0.421 |
| 2nd measurement | 7 ± 3.6 | 0.8–12.1 | |
NMTR: nasal mucociliary transport rate.
The intratest, interobserver, and intraobserver intraclass correlation coefficients (ICC) with 95% confidence intervals for the nasal mucociliary transport rates.
| Type of reliability | ICC (95% CI) |
|---|---|
| Intratest ( | 0.96 (0.916–0.985) |
| Interobserver ( | 0.83 (0.693–0.911) |
| Intraobserver ( | 0.91 (0.832–0.954) |
ICC: intraclass correlation coefficient.
Figure 1A Bland-Altman plot for intratest agreement is shown. The data presented here are NMTR measurements in two rhinoscintigraphy scans in the same subject. The mean difference and 95% confidence interval are indicated on the graph. The y-axis indicates the difference between the two measures (initial, NMTR and second scan, NMTR) and the x-axis indicates the mean of the two measures.
Figure 2A Bland-Altman plot for interobserver agreement is shown. The data presented here are for NMTR measures by two different observers in the same scans. The mean difference and 95% confidence interval are indicated on the graph. The y-axis indicates the difference between the two measures (observer 1, NMTR and observer 2, NMTR) and the x-axis indicates the mean of the two measures.
Figure 3A Bland-Altman plot for intraobserver agreement is shown. The data presented here are for repeated NMTR measures by the same observer. The mean difference and 95% confidence interval are indicated on the graph. The y-axis indicates the difference between the two measures (first and second, NMTR) and the x-axis indicates the mean of the two measures.