Literature DB >> 24736184

Test-retest reproducibility of cannabinoid-receptor type 1 availability quantified with the PET ligand [¹¹C]MePPEP.

Daniela A Riaño Barros1, Colm J McGinnity1, Lula Rosso2, Rolf A Heckemann3, Oliver D Howes1, David J Brooks4, John S Duncan5, Federico E Turkheimer6, Matthias J Koepp5, Alexander Hammers7.   

Abstract

BACKGROUND: Endocannabinoids are involved in normal cognition, and dysfunction in cannabinoid-receptor-mediated neurotransmission has been suggested in a variety of neurological and psychiatric pathologies. The type 1 cannabinoid receptor (CB1) is widely expressed in the human central nervous system. The objective of this study was to quantify the test-retest reproducibility of measures of the PET ligand [(11)C]MePPEP in order to assess the stability of CB1-receptor quantification in humans in vivo.
METHODS: Fifteen healthy subjects (eight females; median age 32 years, range 25 to 65 years) had a 90-minute PET scan on two occasions after injection of a median dose of [(11)C]MePPEP of 364 MBq. Metabolite-corrected arterial plasma input functions were obtained for all scans. Eight ROIs, reflecting different levels of receptor densities/concentrations, were defined automatically: hippocampus, anterior cingulate gyrus, inferior frontal gyrus, caudate nucleus, globus pallidus, nucleus accumbens, thalamus, and pons. We used seven quantification methods: reversible compartmental models with one and two tissue classes, two and four rate constants, and a variable blood volume term (2kbv; 4kbv); model-free (spectral) analyses with and without regularisation, including one with voxel-wise quantification; the simplified reference tissue model (SRTM) with pons as a pseudo-reference region; and modified standard uptake values (mSUVs) calculated for the period of ~30-60 min after injection. Percentage test-retest change and between-subject variability were both assessed, and test-retest reliability was quantified by the intraclass correlation coefficient (ICC). The ratio of binding estimates pallidum:pons served as an indicator of a method's ability to reflect binding heterogeneity.
RESULTS: Neither the SRTM nor the 4kbv model produced reliable measures, with ICCs around zero. Very good (>0.75) or excellent (>0.80) ICCs were obtained with the other methods. The most reliable were spectral analysis parametric maps (average across regions±standard deviation 0.83±0.03), rank shaping regularised spectral analysis (0.82±0.05), and the 2kbv model (0.82±0.09), but mSUVs were also reliable for most regions (0.79±0.13). Mean test-retest changes among the five well-performing methods ranged from 12±10% for mSUVs to 16% for 2kbv. Intersubject variability was high, with mean between-subject coefficients of variation ranging from 32±13% for mSUVs to 45% for 2kbv. The highest pallidum:pons ratios of binding estimates were achieved by mSUV (4.2), spectral analysis-derived parametric maps (3.6), and 2kbv (3.6).
CONCLUSION: Quantification of CB1 receptor availability using [(11)C]MePPEP shows good to excellent reproducibility with several kinetic models and model-free analyses, whether applied on a region-of-interest or voxelwise basis. Simple mSUV measures were also reliable for most regions, but do not allow fully quantitative interpretation. [(11)C]MePPEP PET is well placed as a tool to investigate CB1-receptor mediated neurotransmission in health and disease. Crown
Copyright © 2014. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CB(1); Intra-class correlation coefficient; Positron Emission Tomography; Reliability

Mesh:

Substances:

Year:  2014        PMID: 24736184      PMCID: PMC4283194          DOI: 10.1016/j.neuroimage.2014.04.020

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


Introduction

Endocannabinoids and their receptors are involved in a wide spectrum of conditions, e.g. addiction (Bossong et al., 2009) and epilepsy (Goffin et al., 2011), as well as in normal cognition (Hampson et al., 2011). Two transmembrane G-protein coupled receptor types in the endocannabinoid system have been discovered. Type 1 (CB1) is found in the central nervous system (CNS) and in neuronal and non-neuronal tissues outside the CNS (Matsuda et al., 1990). Abundantly expressed in presynaptic glutamatergic and GABAergic terminals (Katona and Freund, 2008), CB1 receptors have a heterogeneous CNS distribution. High concentrations are found in the cerebral cortex, hippocampus, caudate nucleus and putamen, substantia nigra pars reticulata, globus pallidus, entopeduncular nucleus, the molecular layer of the cerebellum and in pain pathways of brain and spinal cord (Herkenham et al., 1990, Irving et al., 2002). However, the thalamus and most of the brainstem show low concentrations (Herkenham et al., 1990). In the preclinical setting, a wide range of CB1-selective radioligands have been used successfully in vitro, such as [3H]CP-55,940 (Devane et al., 1988, Devane et al., 1992), [3H]SR141716A (Petitet et al., 1996), and [35S]GTPγS (Griffin et al., 1998); and also in vivo, such as (−)-5′-[18F]-Δ8-THC (Charalambous et al., 1991), [123I]AM251 (Gatley et al., 1996), [123I]AM281 (Gatley et al., 1998), [11C]OMAR ([11C]JHU75528) (Horti et al., 2006), [11C]MePPEP (Yasuno et al., 2008), [11C]/[18F]-PipISB (Finnema et al., 2009) and [11C]CB-119 (Hamill et al., 2009). In vivo human brain CB1 availability has recently become quantifiable with PET and the use of tracers such as [18F]MK-9470 (Burns et al., 2007), [11C]OMAR (Wong et al., 2010), [11C]MePPEP (Terry et al., 2009), and [18F]FMPEP-d2 (G.E. Terry et al., 2010b). MePPEP ((3R,5R)-5-(3-methoxy-phenyl)-3-((R)-1-phenyl-ethylamino)-1-(4-trifluoro-methyl-phenyl)-pyrrolidin-2-one) is a CB1-selective inverse agonist. [11C]MePPEP has high and stable brain uptake in vivo. Despite its moderately high lipophilicity (measured LogD7.4 = 4.8) (Yasuno et al., 2008), its specific binding is relatively high with > 85% in monkey brain and 65% determined using CB1 knockout mouse brain (Terry et al., 2008, Terry et al., 2010b, Yasuno et al., 2008). One reproducibility study with [11C]MePPEP has been performed in humans so far, involving eight test–retest scans (Terry et al., 2009) after injection of high doses of [11C]MePPEP (~ 650 MBq). Only standard uptake values and distribution volumes derived from compartmental modelling were examined. In the present study we calculated the reproducibility of various parameters to describe CB1 receptor availability with [11C]MePPEP, including compartmental modelling techniques, spectral analysis variants, a simplified reference tissue model, and simple mSUVs, in regions representative of various CB1 receptor concentrations in 15 healthy volunteers.

Materials and methods

Subjects

Ethical approval was obtained from the London — Surrey Borders Research Ethics Committee, and permission to undertake the study from the UK's radiation protection agency (ARSAC). Seventeen healthy subjects were recruited and gave written informed consent. Exclusion criteria were: history or presence of psychiatric or systemic medical condition, inability to provide informed consent, claustrophobia, any contraindication for undergoing MR, positive urine drug test, positive urine pregnancy test, general practitioner's (family doctor's) advice against participation, regular medication, use of cannabis within the previous three months or on more than five occasions over the subject's lifetime, and pathological modified Allen's test for patency of the ulnar artery (Allen, 1929, Cable et al., 1999, Slogoff et al., 1983). From this sample two were excluded: one subject with pathological modified Allen's test; another withdrew consent for the retest scan. Hence, a total of fifteen healthy subjects (8 females; median age 32 years, range 25 to 65 years), without history of either systemic medical or psychiatric conditions or substance abuse were scanned twice. Demographic data are detailed in Table 1. All subjects underwent a urine drug screen cassette test for 11-nor-∆9-THC, morphine, amphetamine, benzoylecgonine (the main metabolite of cocaine), methamphetamine and oxazepam (Monitect©; BMC, California, U.S.A.) prior to PET scanning. All female patients of childbearing age underwent a urine pregnancy test.
Table 1

Subjects' demographic and injectate details. BMI = Body Mass Index; Min = minimum; Max = maximum.

Subject no.AgeGenderBMIScan interval (days)Dose (MBq)Radiochemistry purity (%)Co-injected mass (μg)Specific activity (MBq/nmol)
128M2324365984.239
364986.227
244M2823375963.056
376994.340
342M25122356962.370
3731002.372
426M241361983.448
366982.761
531M2419353984.238
355992.760
627F21309367994.637
363971.799
732F36373511003.250
3161008.317
865F2223355972.369
371964.042
927M2267369983.943
366983.154
1029F234360979.717
3641005.829
1157M3030373972.960
399965.037
1261F3693361961.892
349961.697
1363F2912384973.550
380983.352
1425F31156364972.469
3571004.437
1562F2410362971.4122
366973.351
Median322424364983.398
Interquartile range(25th-75th)27–6123–3012–93356–37297–992.4–4.338–69
Min25211316961.417
Max65363093991009.7122
Subjects' demographic and injectate details. BMI = Body Mass Index; Min = minimum; Max = maximum.

Radiochemistry

[11C]MePPEP was synthesised on site by Hammersmith Imanet following a procedure described previously (Yasuno et al., 2008). Details of the injectate are listed in Table 1.

PET data acquisition

PET scans were acquired on a Siemens/CTI ECAT EXACT HR + 962 camera (Knoxville, TN, USA) in 3D mode. Ten-minute transmission scans for attenuation correction were obtained prior to dynamic emission scans using a rotating 137Cs point source. Each dynamic acquisition was 90 min long and consisted of 35 frames of increasing length (1 × 30″, 6 × 10″, 3 × 20″, 3 × 30″, 3 × 60″, 6 × 120″, 8 × 300″ and 3 × 600″). 30 s after the scan start, [11C]MePPEP was injected as an intravenous bolus injection of ~ 370 MBq (median 364 MBq, range 316–399 MBq; Table 1). Subjects were scanned on two separate days with a median interval of 24 days (range 1 to 309; Table 1). The head position was maintained throughout and monitored with the camera's positioning laser. If movement was noticed, subjects were repositioned and underwent a second transmission scan at the end of the dynamic scan. To compensate for head movement during dynamic scans, we used a post hoc frame-by-frame realignment method, as described later (section “PET data quantification”). Data were reconstructed using FORE (Defrise et al., 1997) and 2D FBP (ramp filter, kernel 2.0 mm FWHM). Voxel sizes of reconstructed images were 2.092 × 2.092 × 2.42 mm.

Input function derivation

Continuous and intermittent blood samples were collected to allow the subsequent generation of metabolite-corrected arterial plasma time–activity curves (TACs) (Hammers et al., 2008). During the first 15 min blood was withdrawn continuously at a rate of 300 ml/h and radioactivity measured in a BGO detection system (Jones et al., 1994). To quantify plasma and whole blood radioactivity, as well as to allow quantification of the parent fraction of the radiotracer, intermittent discrete (10 ml) samples were taken with heparinised syringes before the scan (baseline) and at the following time points after scan start: 3, 5, 10, 15, 20, 30, and 50 min. At 75 min, a larger 17 ml sample was taken to allow quantification despite radioactivity decay. Parent fraction quantification was not possible at 90 min; hence at this time point only three millilitres was withdrawn for plasma and whole blood radioactivity measurement. Continuous plasma input functions (IF) were derived by cross-calibration and combination of the continuous and discrete data, multiplication with the fitted plasma-over-blood ratio, and correction for parent radiotracer fraction, as described in detail in previous studies (Hammers et al., 2007a, Jones et al., 1994).

MRI data acquisition, analysis and generation of ROIs

All subjects had 3D T1 weighted MRI scans with approximately millimetric voxel sizes on a Phillips Intera 3 Tesla (3 T) MRI scanner (Best, The Netherlands) at the Robert Steiner MRI Unit, Hammersmith Hospital, for co-registration and ROI definition. There was no visible structural abnormality on any of the T1-weighted images. T1-weighted images were segmented into tissue classes using the statistical parametrical mapping software SPM8 (Statistical Parametric Mapping, Wellcome Trust Centre for Neuroimaging, UCL, London, www.fil.ion.ucl.ac.uk/spm) under MATLAB© 7.4 (MathWorks). The T1-weighted images were also anatomically segmented using MAPER (multi-atlas propagation with enhanced registration; Heckemann et al., 2010). Using high-dimensional image registration, 30 MRI data sets, each associated with manually determined labels of 83 regions (Gousias et al., 2008, Hammers et al., 2003), were propagated to the target brain. Label fusion was used to obtain 83 regions of interest (ROIs) in target space (Heckemann et al., 2006). The T1-weighted images and corresponding MAPER-derived individual segmentations as well as individual grey matter (GM) probability images were co-registered with each subject's corresponding processed PET summation image for test and retest scans separately. For the cortical ROIs, the individual atlases in PET space were then multiplied with the grey matter probability maps thresholded at 0.5 using Analyze© 8.1 biomedical imaging software (Mayo Clinic 2002). These regions of interest were then used to sample the dynamic or parametric images.

Manual delineation of the pons

Because the pons is not included in the 83 regions obtained via MAPER, we delineated it manually using Analyze 8.1 (Fig. 1).
Fig. 1

Manual delineation of the pons on MRI. (a) Sagittal view, (b) coronal view, A — Anterior, R — right. The pons was first delineated on sagittal views, followed by coronal and axial views, with the following limits; anterior/ventral: cisterna interpeduncularis and basilar artery (1); posterior/dorsal: floor of the fourth ventricle (2); superior: a line was drawn from the floor of the fourth ventricle below the superior cerebellar peduncle (3) along the lower limit of the cerebral peduncle, to the indentation between the pons and the midbrain (4); inferior: a line was drawn from the floor of the fourth ventricle above the inferior peduncle (6) to the upper limits of the olive and pyramid of the medulla oblongata (7), i.e. to the indentation between the pons and medulla oblongata (8); on coronal view: following anatomical boundaries of pons, which are clearly visible; on axial view: following delineation in both sagittal and coronal views, the pons is now clearly delineated, and the axial view is used for verification. [5 — posterior cerebral artery].

Manual delineation of the pons on MRI. (a) Sagittal view, (b) coronal view, A — Anterior, R — right. The pons was first delineated on sagittal views, followed by coronal and axial views, with the following limits; anterior/ventral: cisterna interpeduncularis and basilar artery (1); posterior/dorsal: floor of the fourth ventricle (2); superior: a line was drawn from the floor of the fourth ventricle below the superior cerebellar peduncle (3) along the lower limit of the cerebral peduncle, to the indentation between the pons and the midbrain (4); inferior: a line was drawn from the floor of the fourth ventricle above the inferior peduncle (6) to the upper limits of the olive and pyramid of the medulla oblongata (7), i.e. to the indentation between the pons and medulla oblongata (8); on coronal view: following anatomical boundaries of pons, which are clearly visible; on axial view: following delineation in both sagittal and coronal views, the pons is now clearly delineated, and the axial view is used for verification. [5 — posterior cerebral artery]. We evaluated the test–retest reliability of the quantification methods (see “PET data quantification” section) in a selection of eight bilateral ROIs in total. We chose representative regions with high CB1 receptor concentrations; the grey matter masked cortical structures — hippocampus, anterior cingulate gyrus, and inferior frontal gyrus; and the subcortical structures in their entirety, i.e. not grey matter masked (Heckemann et al., 2011) — caudate nucleus, globus pallidus, and nucleus accumbens. In addition, two regions with low concentration of CB1 receptors were evaluated: the thalamus and the manually defined (entire) pons. The data from left and right homologues were averaged prior to quantification.

PET data quantification

All dynamic PET images were de-noised and corrected for movements frame-by-frame using wavelets in Piwave 8.0 (Studholme et al., 1996, Turkheimer et al., 1999). The frame starting at 4 min (frame 10) was used as reference due to its high signal-to-noise ratio and likelihood of subjects staying still during the first minutes of the scan. The first 93 s (frames 1 to 6) were not motion corrected due to their low signal-to-noise ratio. The remaining frames (7 to 35) were automatically re-sliced and re-concatenated into a new dynamic image (Hammers et al., 2007a). A binary contiguous mask encompassing the entire brain and extending approximately 10 mm beyond the outer cortical boundary was created semi-automatically using Analyze 8.1 and applied to both dynamic and summed radioactivity-weighted images (ADD images) to reduce computation time. Regional quantification of distribution/binding/uptake was then performed. In all following analyses, assessment was based on the same ROIs. Binding parameters were calculated directly for the ROI TAC data, except in the “classic” spectral analysis, where the additional aim was the assessment of the quality of parametric maps for use in voxel-by-voxel analyses, and the parametric map itself was sampled using the same ROIs: Compartmental models, requiring arterial IFs (section “Compartmental models, requiring 1 arterial IFs”): Reversible two-compartment (one tissue compartment) model with variable blood volume (2kbv) (section “Reversible two-compartment (one tissue compartment) model with two rate constants and a variable blood volume (2kbv)”) Reversible three-compartment (two tissue compartment) model with variable blood volume (4kbv) (section “Reversible three-compartment (two tissue compartment) model with four rate constants and a variable blood volume (4kbv)”) Model-free analyses, requiring arterial IFs (section “Model-free analyses, requiring arterial IFs”): “Classic” (non-regularised) spectral analysis (SA), applied to ROI time-activity data (section ‘“Classic” (non-regularised) SA’). “Classic” SA, applied on a voxel-by-voxel basis to create parametric maps of VT, which were then sampled in the same ROIs as for the other methods (section “Sampling parametric VT images obtained voxel-by-voxel using spectral analysis (“Classic” SA)”). Rank shaping regularisation of spectral analysis (SA; section “Directly obtaining VT values from ROI data with SA and rank shaping regularisation”) Methods not requiring arterial IFs (section “Methods not requiring an arterial IF”): Simplified reference tissue model (SRTM) using pons as a pseudo-reference tissue (section “Simplified reference tissue model using pons as a pseudo-reference tissue”) (Regional) modified standard uptake values (mSUVs) (section “Modified standard uptake values (mSUVs)”)

Compartmental models, requiring arterial IFs

Reversible two-compartment (one tissue compartment) model with two rate constants and a variable blood volume (2kbv)

In this model, three microparameters are derived: K1 is the influx of the ligand from the plasma to the tissue compartment containing free, non-specifically bound, and specifically bound ligand, k2 is the efflux constant from the ROI back to plasma (Cunningham et al., 1991, Huang et al., 1980), and bv is a variable blood volume term. VT is then calculated according to the compartmental model equation (Watabe et al., 2006):

Reversible three-compartment (two tissue compartment) model with four rate constants and a variable blood volume (4kbv)

K1 and k2 were calculated as for the 2kbv compartmental model described above; in addition, two additional rate constants were estimated to describe transfer relating to the third compartment: k3, which describes the transfer from the free and non-specifically bound compartment to the specifically bound (third) compartment; and k4, which describes the opposite transfer (Cunningham et al., 1991, Huang et al., 1980). Again, a variable blood volume term was also computed. According to compartmental model equations (Gunn et al., 2001, Watabe et al., 2006):

Model-free analyses, requiring arterial IFs

“Classic” (non-regularised) SA

Volumes of distribution (VTs) (Innis et al., 2007) for each ROI were obtained from the dynamic images and the metabolite-corrected IFs using spectral analysis (SA) (Cunningham and Jones, 1993, Cunningham et al., 1993, Turkheimer et al., 1994). The fast frequency boundary was kept at the default value of 0.1 s− 1. The theoretical slow frequency boundary is given by the decay constant of 11C (t½ ≈ 20 min, decay constant 0.0005663 s− 1; log10 = − 3.25). Based on previous work with another tracer with relatively slow kinetics (Hammers et al., 2007a), we changed this to 0.00063 s− 1 (log10 = − 3.20) in order to reduce noise.

Sampling parametric VT images obtained voxel-by-voxel using spectral analysis (“Classic” SA)

Parametric images of [11C]MePPEP VT were obtained from the dynamic images and the metabolite-corrected IFs using spectral analysis (SA; Cunningham and Jones, 1993, Cunningham et al., 1993) and receptor parametric mapping software (RPM6; Aston et al., 2001, Gunn et al., 1997) with the same fast and slow frequency boundaries as above. The resulting parametric maps of VT values were then sampled in the eight selected ROIs.

Directly obtaining VT values from ROI data with SA and rank shaping regularisation

VT values were generated directly from dynamic data sampled using ROIs with rank shaping (RS; orthogonalized-functional-base) regularisation of SA (Turkheimer et al., 2003) using in-house “Clickfit” software. As previously described by Turkheimer et al. (2003), we used the metabolite-corrected IF, a logarithmically spaced basis, an exponential range of bases extending to − 3.2, and the regional tissue TAC. TACs were weighted according to (Gunn et al., 1998):[wi — weight for frame i; Li — length of frame i (seconds); and Ti — rate of true coincidences (per second)]. The VT for each ROI was then obtained as the plateau of the VT(R), where R is the expected signal-to noise ratio that is used as the regularisation parameter (R) in rank-shaping (Fig. 2; (Turkheimer et al., 2003)).
Fig. 2

Example plot showing a VT of 12 obtained for the hippocampus from the VT(R) plateau (see section "Directly obtaining VT values from ROI data with SA and rank shaping regularisation").

Example plot showing a VT of 12 obtained for the hippocampus from the VT(R) plateau (see section "Directly obtaining VT values from ROI data with SA and rank shaping regularisation").

Methods not requiring an arterial IF

Simplified reference tissue model using pons as a pseudo-reference tissue

CB1 receptors are widespread in the brain, and a true reference region devoid of specific binding does not exist. A recent attempt to obviate the invasive procedure of arterial cannulation has been to use the ROI with the lowest receptor concentration as a pseudo-reference region (Turkheimer et al., 2012). One of the structures with a low concentration of CB1 receptors is the pons (Yasuno et al., 2008). We therefore used the pons as a pseudo-reference region in the simplified reference tissue model (SRTM).

Modified standard uptake values (mSUVs)

Modified standard uptake values (mSUVs; Innis et al., 2007) for frames 25–31, i.e. from 29 min 50 s to 58 min 50 s after injection, were also derived for the ROIs according to (Goffin et al., 2011):

Global intensities (GI)

Global intensities (GI) were calculated with an in-house script derived from SPM (Hammers et al., 2007b), where the GI is defined as the mean voxel value within a mask defined as all voxels exceeding 1/8 of the mean value of all voxels in the image matrix.

Statistical analyses

For statistical testing we used SPSS© for Windows version 16 software (IBM 2008, New York, U.S.A.). Injectate data were compared between test and retest sessions using the non-parametric Wilcoxon signed-rank test. The percentage test–retest difference of parameters obtained with the various methods was calculated for all subjects in ROIs according to: Reliability was calculated using intraclass correlation coefficients (Maclennan, 1993):where MS = mean sum of squares, BS = between-subjects, WS = within-subjects, and df = degrees of freedom as computed in SPSS, using the “one-way random” model and reporting the “single measures” ICC. ICC values ≥ 0.75 were considered indicators of good reliability (Portney and Watkins, 2009). We used a Bland–Altman plot to compare methods and assess bias. In the Bland–Altman plot (also known as Tukey mean-difference plot), the average of two VT measures for the same region is plotted on the x-axis, whereas the first VT minus the second VT is plotted on the y axis. Where quantification from two methods is in close agreement and without bias, the datapoints will be scattered close to y = 0, equally above and below the x axis. In this case, the 2kbv model was used as the reference, i.e. VT2 was always the average derived from 2kbv. The association between percentage test–retest difference and interscan interval was quantified for the method yielding the highest ICCs using Spearman's rho correlation coefficient, with correction for multiple comparisons (8 regions) using the Bonferroni method. The volumes of distribution between genders were also compared using a repeated measures full-factorial general linear model, for the same method.

Results

Injectate

Details are given in Table 1. There were no significant differences between test and retest studies in terms of the amount of injected radioactivity (median (i.q.r)): test 362 (358–368) MBq; retest 366 (360–372) MBq; co-injected mass of stable ligand: test: 3.2 (2.4–4.1) μg, retest 3.3 (2.7–4.7) μg; and specific activity at the time of injection: test 50 (49–61) MBq/ηmol, retest: 51 (37–61) MBq/ηmol.

Image data

Global intensities of summed radioactivity images did not differ between test and retest studies (median, interquartile 25th–75th: test: 1.2, 1.0–1.6; retest: 1.3, 1.1–1.5; p > 0.6). Fig. 3 shows examples of time–activity curves.
Fig. 3

Average time activity curves for the pallidum (top) and pons (bottom): the average uptake in each region as a function of time in minutes, subsequently fitted with a two-compartment (2kbv) model.

Average time activity curves for the pallidum (top) and pons (bottom): the average uptake in each region as a function of time in minutes, subsequently fitted with a two-compartment (2kbv) model.

Quantification results

The following sections describe the regional estimates for the parameters derived with the seven quantification methods. To assess test–retest variation, for each ROI the median percent difference between test and retest studies as well as their signed range is given in the tables. The coefficient of variation (standard deviation divided by the mean) quantifies the between-subject variability of the measure. The ICC assesses the reliability of the measure as a function of both within-subject variability and between-subjectvariability; the closer to the value of 1, the more reliable the method, i.e. the smaller the intra-subject variability of the measure compared with natural between-subject variability. Finally, the ratio of the generally highest binding region (pallidum) over the lowest binding region (pons) assesses a method's ability to reflect known binding heterogeneity. A comparison of analysis methods and a synthetic overview of the various measures will be provided in the section “Comparison between analysis methods”.

Reversible two-compartment (one tissue compartment) model with variable blood volume (2kbv)

The region with the highest VT was globus pallidus (10.8; Table 2). Regional heterogeneity of VT values was high, with a ratio of pallidum:pons of 3.6. ICCs ranged between 0.69 and 0.95, with a mean ± SD of 0.82 ± 0.09.
Table 2

Subjects' volume of distribution (VT) obtained with two-compartment model (2kbv) method. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diffMedian % diff rangeMean BS % CVICC
Hippocampus8.06.2–10.84.124.814.8− 54.8–54.250.40.88
ACG10.37.5–14.01.026.427.8− 154.4–64.247.40.76
IFG8.87.3–12.34.122.418.1− 48.3–31.942.10.83
Caudate7.46.0–12.23.922.919.7− 60.9–33.548.00.85
Pallidum10.88.5–14.21.132.620.6− 158.7–44.148.10.70
Accumbens8.47.2–13.21.231.735.8− 150.5–51.553.70.69
Thalamus5.14.4–7.32.910.912.6− 35.5–28.535.90.89
Pons3.02.8–3.92.06.28.3− 10.7–20.230.20.95
Mean(SD)19.7(8.7)44.5(7.9)0.82(0.09)
Subjects' volume of distribution (VT) obtained with two-compartment model (2kbv) method. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

Reversible three-compartment (two tissue compartment) model with variable blood volume (4kbv)

The method yielded highly variable data. Unlike for the other methods, the regions with the highest VT values were nucleus accumbens (13.6; Table 3) and hippocampus (13.4). The ratio of pallidum/pons was 2.0. ICCs ranged between − 0.13 and 0.50, with a mean ± SD of 0.14 ± 0.25.
Table 3

Subjects' VT obtained with three-compartment model (4kbv). ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diffMedian % diff rangeMean BS % CVICC
Hippocampus13.47.5–19.6− 0.7102.272.8− 219.9–175.681.1− 0.05
ACG9.05.8–13.61.465.653.7− 136.2–12681.40.23
IFG8.94.7–11.20.818.661.1− 159–116.451.90.13
Caudate6.24.2–8.50.031.568.5− 153.4–200.069.9− 0.13
Pallidum10.66.7–18.33.479.869.7− 170.7–126.1111.3− 0.03
Accumbens13.68.7–39.50.0163.5122.1− 72.3–200.0131.7− 0.06
Thalamus6.14.5–8.41.230.532.7− 133.8–102.587.90.49
Pons5.33.9–7.22.423.040.3− 23.4–146.579.00.50
Mean(SD)65.1(27.1)86.8(24.6)0.14(0.25)
Subjects' VT obtained with three-compartment model (4kbv). ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

Directly obtaining VT values from ROI data with “classic” spectral analysis (SA)

The region with the highest VT values was globus pallidus (15.7; Table 4). Regional heterogeneity of VT values, estimated as the ratio of pallidum over pons, was 2.6. ICCs ranged between 0.67 and 0.87, with a mean ± SD of 0.76 ± 0.07.
Table 4

Subjects' volume of distribution (VT) obtained with Spectral Analysis (SA) based on ROI data. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diffMedian % diff rangeMean BS % CVICC
Hippocampus12.49.4–17.26.623.410.9− 39.3–29.634.10.87
ACG14.411.9–19.97.327.112.4− 64.3–39.335.00.74
IFG13.910.1–19.35.426.313.3− 76.3–47.339.00.71
Caudate13.09.3–19.45.928.113.6− 80.8–26.344.20.74
Pallidum15.712–21.78.228.99.4− 53.8–33.535.50.85
Accumbens13.911.3–18.96.926.715.1− 63.6–47.135.20.80
Thalamus9.66.9–12.24.820.324.7− 60.7–49.239.40.70
Pons6.04.6–7.12.911.824.8− 62.0–39.935.50.67
Mean(SD)15.5(6.0)37.2(3.4)0.76(0.07)
Subjects' volume of distribution (VT) obtained with Spectral Analysis (SA) based on ROI data. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

Sampling parametric VT images obtained with “classic” spectral analysis

The region with the highest VT was the pallidum (15.8; Table 5). Regional heterogeneity of VT values was moderate, with a ratio of pallidum over pons of 3.6. ICCs were fairly homogenous between regions and ranged between 0.76 and 0.87, with a mean ± SD of 0.83 ± 0.03. Fig. 4 shows an example of a parametric map.
Table 5

Subjects' volume of distribution (VT) obtained with “classic” spectral analysis (SA) on parametric maps. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diffMedian % diff rangeMean BS % CVICC
Hippocampus11.59–16.27.022.69.6− 40.1–20.634.20.87
ACG14.811.1–20.58.128.812.5− 44.0–30.134.70.85
IFG14.810.4–20.37.627.612.0− 49.7–27.037.00.85
Caudate12.910.2–19.36.526.912.3− 76.6–24.340.00.81
Pallidum15.811.6–21.18.630.412.6− 53.0–23.535.40.83
Accumbens9.57.8–13.95.318.712.3− 44.6–31.436.00.83
Thalamus13.210.4–17.35.226.516.8− 78.9–50.837.10.76
Pons4.43.5–5.31.79.620.2− 33.1–43.339.00.81
Mean(SD)13.5(3.3)36.7(2.0)0.83(0.03)
Fig. 4

Example of a parametric map, co-registered onto the subject's MRI scan. Left, sagittal; middle, coronal; right, transverse. Note high binding in the putamen and pallidum and intermediate binding in the hippocampus and thalamus. Colour bar: VT values. P, posterior; A, anterior; R, right; L, left.

Subjects' volume of distribution (VT) obtained with “classic” spectral analysis (SA) on parametric maps. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation. Example of a parametric map, co-registered onto the subject's MRI scan. Left, sagittal; middle, coronal; right, transverse. Note high binding in the putamen and pallidum and intermediate binding in the hippocampus and thalamus. Colour bar: VT values. P, posterior; A, anterior; R, right; L, left.

Spectral analysis with rank shaping regularisation

The region with the highest VT values was globus pallidus (10.3; Table 6). Regional heterogeneity of VT values was lower than with the preceding methods, with a ratio of pallidum over pons of 2.4. ICCs ranged between 0.73 and 0.90, with a mean ± SD of 0.82 ± 0.05.
Table 6

Subjects' Volume of distribution (VT) obtained with Rank Shaping (RS) regularisation of Spectral Analysis (SA) method. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diffMedian % diff rangeMean BS % CVICC
Hippocampus8.25.8–10.44.215.214.4− 48.5–34.935.90.81
ACG9.97.6–13.75.518.814.6− 29.7-32.434.00.86
IFG9.97.2–13.85.318.215.6− 39.5-29.034.80.85
Caudate8.16.1–12.64.418.111.6− 88.7-27.042.20.82
Pallidum10.37.0–13.04.520.723.3− 64.1-42.339.70.77
Accumbens8.66.1–10.53.215.918.5− 77.8-58.436.50.73
Thalamus6.55.5–9.43.512.714.9− 43.9-31.034.70.85
Pons4.33.3–5.32.58.07.4− 30.6-24.132.30.90
Mean(SD)15.0(4.7)36.3(3.2)0.82(0.05)
Subjects' Volume of distribution (VT) obtained with Rank Shaping (RS) regularisation of Spectral Analysis (SA) method. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

SRTM with pons as a pseudo-reference tissue

The method yielded inconsistent data. The regions with the highest values were the globus pallidus, the anterior cingulate gyri, and the nucleus accumbens (BPND = 1.1; Table 7). The ratio of pallidum over pons could not be calculated, as the BPND of pons as the reference region is ~ 0. ICCs ranged between − 0.29 and 0.50, with a mean ± SD of 0.07 ± 0.27.
Table 7

Subjects' binding potential (BPND) obtained with the SRTM and pons as a pseudo-reference region. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedian BPNDInterquartile rangeMinMaxMedian % diff.Median % diff rangeMean %BS-CVICC
Hippocampus1.00.8–1.70.412.854.6− 155.5–176.6125.2− 0.06
ACG1.10.9–1.20.73.440.2− 142.9–71.7− 574.10.50
IFG0.90.9–1.00.01.716.0− 66.6–207.629.4− 0.29
Caudate0.90.6–1.00.22.730.5− 137.5–45.448.80.06
Pallidum1.11.0–1.30.11.69.4− 37.9–158.425.10.27
Accumbens1.10.7–1.6− 0.218.253.0− 213.9–180.6157.4− 0.15
Thalamus1.00.5–6.20.410.442.3− 169.8–181.2108.20.19
Mean(SD)35.1(17.4)0.07(0.27)
Subjects' binding potential (BPND) obtained with the SRTM and pons as a pseudo-reference region. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation. The region with the highest values was globus pallidus (3.6; Table 8). Regional heterogeneity of values was the highest of all methods tested with the ratio of pallidum over pons 4.2. ICCs ranged from 0.47 to 0.86, with a mean ± SD of 0.79 ± 0.13.
Table 8

Subjects' modified standard uptake values (mSUV). ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

ROIMedianInterquartile rangeMinMaxMedian % diff.Median % diff rangeMean %BS-CVICC
Hippocampus2.72.1–3.21.84.28.3− 22.6–34.427.40.84
ACG3.22.6–3.82.05.28.8− 24.1–32.727.20.86
IFG3.22.6–3.72.15.38.9− 22.4–35.127.30.86
Caudate2.92.5–3.91.95.17.6− 58.1–30.330.10.79
Pallidum3.62.7–4.12.25.511.1− 28.6–30.927.10.84
Accumbens3.02.4–3.61.54.76.7− 65.7–33.727.90.80
Thalamus2.72.2–3.21.74.38.1− 16.7–38.125.80.83
Pons0.90.6–1.30.33.436.77.3–108.262.60.47
Mean(SD)12.0(10.1)31.9(12.5)0.79(0.13)
Subjects' modified standard uptake values (mSUV). ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. BS = between-subjects, CV = coefficient of variation, diff = difference, ICC = intraclass correlation coefficient, Min = minimum, Max = maximum, ROI = region-of-interest, SD = standard deviation.

Comparison between analysis methods

Relative to the 2kbv model, a bias towards overestimation of medium high hippocampal VT of [11C]MePPEP was seen for both analyses using “classic” SA (Fig. 5). RS-SA did not show this bias but restricted the range of VT estimates, with an underestimation of the highest VTs. The 4kbv model was not assessed due to its lack of reliability.
Fig. 5

Bland–Altman plot for the different methods to obtain VTs. Data for the hippocampus is shown as an example, relative to the one compartment, two-rate constant model (blue diamonds, 2kbv); green triangles: rank-shaping regularisation of spectral analysis; red squares: “classic” voxel-wise SA; and purple circles: “classic” SA on ROI data.

Bland–Altman plot for the different methods to obtain VTs. Data for the hippocampus is shown as an example, relative to the one compartment, two-rate constant model (blue diamonds, 2kbv); green triangles: rank-shaping regularisation of spectral analysis; red squares: “classic” voxel-wise SA; and purple circles: “classic” SA on ROI data. Table 9 provides an overview of the median test–retest differences (%) for the different methods. 2kbv and the methods using SA had median differences between 13 and 20%, similar across regions as indicated by low spreads (SDs), whilst mSUVs varied even less on average, but with more between-region variation due to the pons showing high test–retest differences (37%). 4kbv and SRTM were very variable for most regions.
Table 9

Median test–retest differences (%) for subjects' parameter estimates (VT/BPND/mSUV) obtained with the different methods. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation.

Method
2kbv
4kbv
SA-ROIs
SA-maps
RS-SA
SRTM
mSUV
Parameter
VT
VT
VT
VT
VT
BPND
kBq/ml
SamplingROI on dynamic imagesROI on dynamic imagesROI on dynamic imagesROI on parametric mapsROI on dynamic imagesROI on dynamic imagesROI on summed images
Hippocampus14.872.810.99.614.454.68.3
ACC27.853.712.412.514.640.28.8
IFG18.161.113.312.015.616.08.9
Caudate19.768.513.612.311.630.57.6
Pallidum20.669.79.412.623.39.411.1
Accumbens35.8122.115.112.318.553.06.7
Thalamus12.632.724.716.814.942.38.1
Pons8.340.324.820.27.4NA36.7
Mean ± SD19.7 ± 8.765.1 ± 27.115.5 ± 5.913.5 ± 3.315.0 ± 4.635.1 ± 17.412.0 ± 10.1
Median test–retest differences (%) for subjects' parameter estimates (VT/BPND/mSUV) obtained with the different methods. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation. Mean between-subject coefficients of variation (BSCV; %) for the different methods are listed in Table 10. The between-subject variability based on mSUVs (i.e. tissue data only) was approximately 32%; however the BSCV for pons was 63%. The three methods based on SA had similar between-subject variation, around 36%, with similar variability for the various regions. Between-subject variability was higher for the 2kbv compartmental model, at 45%. SRTM and the 4kbv model yielded implausible values.
Table 10

Mean between-subject coefficients of variation (BSCV; %) for subjects' VT/BPND/mSUV parameters obtained with the different methods. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation, NA = not applicable.

Method
2kbv
4kbv
SA-ROIs
SA-maps
RS-SA
SRTM
mSUV
Parameter
VT
VT
VT
VT
VT
BPND
kBq/ml
SamplingROI on dynamic imagesROI on dynamic imagesROI on dynamic imagesROI on parametric mapsROI on dynamic imagesROI on dynamic imagesROI on summed images
Hippocampus50.481.134.134.235.9125.227.4
ACG47.481.435.034.734.0− 574.127.2
IFG42.151.939.037.034.829.427.3
Caudate48.069.944.240.042.248.830.1
Globus Pallidum48.1111.335.535.439.725.127.1
Accumbens53.7131.735.236.036.5157.427.9
Thalamus35.987.939.437.134.7108.225.8
Pons30.279.035.539.032.3NA62.6
Mean ± SD44.5 ± 7.986.8 ± 24.637.2 ± 3.436.7 ± 2.036.3 ± 3.2− 11.4 ± 253.231.9 ± 12.5
Mean between-subject coefficients of variation (BSCV; %) for subjects' VT/BPND/mSUV parameters obtained with the different methods. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation, NA = not applicable. ICCs for all methods are listed in Table 11. As expected from the high test–retest variability (Table 9) and unrealistically high between-subject variability (Table 10), the 4kbv model and SRTM yielded non-reproducible results, as reflected by an ICC around zero. All the other methods had good to very good reproducibility, ranging from 0.76 ± 0.07 for classic SA calculated on ROI data to 0.83 ± 0.04 for classic SA applied to parametric maps. Note the low between-region spread of the ICC for the five methods with good or very good reproducibility, meaning that reproducibility was good throughout the brain regions sampled.
Table 11

Intraclass correlation coefficients (ICCs) for subjects' volume of distribution (VT) and/or binding potential (BP) obtained with the different methods. The ratio VT/BP of a high binding region (pallidum) over that of a low-binding region (pons) is also given. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation, NA = not applicable.

Method
2kbv
4kbv
SA-ROIs
SA-maps
RS-SA
SRTM
mSUV
Parameter
VT
VT
VT
VT
VT
BPND
kBq/ml
SamplingROI on dynamic imagesROI on dynamic imagesROI on dynamic imagesROI on parametric mapsROI on dynamic imagesROI on dynamic imagesROI on summed images
Hippocampus0.88− 0.050.870.870.81− 0.060.84
ACG0.760.230.740.850.860.500.86
IFG0.830.130.710.850.85− 0.290.86
Caudate0.85− 0.130.740.810.820.060.79
Pallidum0.70− 0.030.850.830.770.270.84
Accumbens0.69− 0.060.800.830.73− 0.150.80
Thalamus0.890.490.700.760.850.190.83
Pons0.950.500.670.810.90NA0.47
Mean ± SD0.82 ± 0.090.14 ± 0.250.76 ± 0.070.83 ± 0.030.82 ± 0.050.07 ± 0.270.79 ± 0.13
Ratio pallidum/pons3.62.02.63.62.4NA4.2
Intraclass correlation coefficients (ICCs) for subjects' volume of distribution (VT) and/or binding potential (BP) obtained with the different methods. The ratio VT/BP of a high binding region (pallidum) over that of a low-binding region (pons) is also given. ACG = anterior cingulate gyrus, IFG = inferior frontal gyrus, caudate = caudate nucleus, pallidum = globus pallidus, accumbens = nucleus accumbens. ROI = region-of-interest, SD = standard deviation, NA = not applicable. Table 11 also shows the ratio between a high-binding region (pallidum) and a low-binding region (pons), indicating a method's ability to reflect the known between-region heterogeneity. mSUVs had the highest differential, followed by 2kbv model and SA applied to parametric maps. A positive correlation was observed for test–retest difference and interscan interval in the inferior frontal gyrus (p = 0.039, Spearman's rho = 0.538) and the caudate (p = 0.033, Spearman's rho = 0.550). These correlations were rendered insignificant by correction for multiple comparisons. There was no significant influence of gender on the VTs (F = 27.349, p = 0.995). There was no significant interaction between gender and test–retest condition (p = 0.120).

Discussion

We describe the test–retest reproducibility of quantification for CB1-receptor availability, as assessed by [11C]MePPEP PET, in 15 healthy human subjects. Our major finding is that good-to-excellent reproducibility of estimates of availability is achievable using either the one tissue compartment, two rate-constant kinetic model with a variable blood volume term; model-free analyses using spectral analysis variants; or simple scaled measures of radioactivity (mSUV). The performance of the various methods was consistent between measures — those having low percentage test–retest variability also had high ICCs, reflecting that among the well-performing methods, between-subject variability was comparable. The 2kbv compartmental model was among the best performing methods for test–retest variability and reliability, and also had one of the highest ratios of pallidum over pons. This indicates low bias (i.e. a large range of concentrations between regions of known high and low receptor availability). This ratio was lower for the spectral analysis variants applied to ROI data, reflecting their known bias towards lower VT estimates in high binding regions (Hammers et al., 2007a). In contrast, voxel-wise SA had the same high pallidum/pons ratio as the 2kbv model. This may be due to SA's ability to fit voxel-wise time courses — voxels with varying partial volume contributions of white matter or vasculature can be individually fitted, which is not the case for methods using the averaged ROI TAC. Several, but not all (e.g. Ahmad et al., 2014, Goffin et al., 2011, Van Laere et al., 2010), earlier in vivo human studies with [18F]MK-9470 (Burns et al., 2007), [11C]MePPEP (Terry et al., 2009) and [18F]FMPEP-d2 (Terry et al., 2010b) involved 120 to 300 min scan times (Terry et al., 2009, Terry et al., 2010b). This requirement limits the usefulness of these authors' approaches, as patients with debilitating conditions and even healthy volunteers are unlikely to tolerate PET scans of 2 h duration or more. Here we present data that indicates that with [11C]MePPEP, reliable quantification of CB1 receptor availability is achievable with just 90 min of data acquisition. In a previous study, it has been shown that 90 min of acquisition is sufficient for obtaining stable VT estimates (Terry et al., 2009). In addition, the injected doses used in previous studies were generally approximately twice as high as the doses used in our study, up to 750 MBq of [11C]MePPEP (Terry et al., 2009). We achieved reliable receptor availability estimation using only 370 MBq, entailing an effective dose of just ~ 1.7 mSv per scan (Terry et al., 2010a). We had previously observed that both image quality and the reliability of blood data measurements were lower when injected doses of a radioligand with similarly slow kinetics were lowered to ~ 180 MBq (Hammers et al., 2007a). In our hands, mSUVs – using only tissue data – yielded excellent test–retest properties and differentiation between regions, with the highest pallidum/pons ratio of all methods. The fact that excellent reliability and differentiation between regions with high and low receptor concentrations (Herkenham et al., 1990) could be achieved with methods using metabolite-corrected arterial plasma input functions suggests the reliability of the blood measurements. Because arterial cannulations require skilled personnel and involve discomfort and small risks to volunteers and patients, non-invasive PET studies are usually preferred in research studies, and even more so in a clinical environment. Methods using a reference region devoid of the studied receptor are needed for full quantification in the absence of an input function. However, CB1 receptors are present throughout the brain, and a true reference region does not exist. Here we used the pons as a pseudo-reference region. It has low CB1 receptor concentration (Herkenham et al., 1990, Irving et al., 2002, Terry et al., 2009, Yasuno et al., 2008), motivating this attempt despite some specific binding (Terry et al., 2009, Yasuno et al., 2008). We were unable to achieve reliable data. The application of more sophisticated pseudo-reference region approaches as described in recent studies (Turkheimer et al., 2012) might improve on these results. However, we note that the pons tissue data (i.e. mSUV) measurements were far less reliable than measurements elsewhere. Even small variations in the amount of specific binding between individuals may thus have a large influence on the radioactivity concentration in this region, with resulting low reliability for the SRTM. This is the first study to apply model-free analyses (spectral analysis with or without rank shaping regularisation) to quantify cannabinoid receptor availability using [11C]MePPEP PET. These have the advantage of being ‘data-driven’ rather than requiring an a priori model selection. We additionally describe the first voxel-wise quantification of [11C]MePPEP, yielding parametric VT images with high corresponding regional ICCs. Spectral analysis does not require a priori assumptions regarding the number of components, compartments, or distribution of receptors. Spectral analysis estimations require compartmental systems that are strongly connected, have exchange of material with the environment confined to a single compartment, and do not contain cycles, i.e., there is no possibility for material to pass from one compartment through two or more compartments back to the initial compartment (Schmidt, 1999). SA cannot be used to estimate reference region models because the fit assumes a sum of positive series of convolution integrals of the input function. This last condition is relaxed in Rank-Shaping SA. We do not expect any biases when spectral analysis is applied to data from participants who are not healthy controls. SA has been used successfully in several patient populations. The improved ICC measures of SA methodologies over compartmental ones indicate a complex compartmentalisation of the underlying receptor distribution. CB1 receptors can be found on neurons, astrocytes, and also the vascular endothelium. Compartmental models usually assume that a single concentration represents the free-in-tissue tracer compartment. This concentration in reality is the average of concentrations of the free radioligand in different tissue environments, as there will be a gradient across different cellular elements. This will cause an apparent change in affinity of the tracer depending on the target cell (Delforge et al., 1996). Spectral analysis, which does not depend on a free compartmental structure, has more flexibility in dealing with such a complex signal. A major difference relative to the previous test–retest study (Terry et al., 2009) is the lack of reliability of VT estimates obtained with the two-tissue compartment model (4kbv) in our study, as well as good reliability for VT estimates obtained using the one-tissue compartment model 2kbv, whereas this had yielded poor fits for Terry et al. (2009). This might relate to longer scanning time and nearly twice the injected dose in the former study. An additional major difference in the models is that we estimated the blood volume contribution, whereas this had been set to 5% in the previous study. Of note, for a similar time interval our standardized uptake values are comparable to those of Terry et al. (2009). We did not collect data from the female participants concerning the stage of their menstrual cycle on the day of scanning. Here, when this was tested for the “classic” spectral analysis (parametric maps) method, there was no significant between-subject influence of gender on the VTs; nor was there a significant interaction between gender and test–retest condition. Whilst further investigation is required, we therefore hypothesise that the menstrual cycle has a minimal effect on the variability of [11C]MePPEP VT in human females. We did not calculate the parent tracer free fraction, which may be important (Terry et al., 2010a, Terry et al., 2010b, Yasuno et al., 2008). However, our result of good reproducibility with tissue-only data (mSUV) and even better reproducibility with modelling approaches using the arterial input data suggests that this omission did not have an adverse effect. In conclusion, quantification of CB1 receptor availability showed good-to-excellent reproducibility with selected kinetic and model-free analyses, whether applied on a region-of-interest or voxel-wise basis. [11C]MePPEP PET is well-placed as a tool to investigate CB1 receptor-mediated neurotransmission in health and neuropsychiatric disease.
  53 in total

1.  Rank-shaping regularization of exponential spectral analysis for application to functional parametric mapping.

Authors:  Federico E Turkheimer; Rainer Hinz; Roger N Gunn; John A D Aston; Steve R Gunn; Vincent J Cunningham
Journal:  Phys Med Biol       Date:  2003-12-07       Impact factor: 3.609

2.  Imaging the brain marijuana receptor: development of a radioligand that binds to cannabinoid CB1 receptors in vivo.

Authors:  S J Gatley; R Lan; N D Volkow; N Pappas; P King; C T Wong; A N Gifford; B Pyatt; S L Dewey; A Makriyannis
Journal:  J Neurochem       Date:  1998-01       Impact factor: 5.372

3.  PET studies in the primate brain and biodistribution in mice using (-)-5'-18F-delta 8-THC.

Authors:  A Charalambous; G Marciniak; C Y Shiue; S L Dewey; D J Schlyer; A P Wolf; A Makriyannis
Journal:  Pharmacol Biochem Behav       Date:  1991-11       Impact factor: 3.533

4.  11C-JHU75528: a radiotracer for PET imaging of CB1 cannabinoid receptors.

Authors:  Andrew G Horti; Hong Fan; Hiroto Kuwabara; John Hilton; Hayden T Ravert; Daniel P Holt; Mohab Alexander; Anil Kumar; Arman Rahmim; Ursula Scheffel; Dean F Wong; Robert F Dannals
Journal:  J Nucl Med       Date:  2006-10       Impact factor: 10.057

5.  The PET radioligand [11C]MePPEP binds reversibly and with high specific signal to cannabinoid CB1 receptors in nonhuman primate brain.

Authors:  Fumihiko Yasuno; Amira K Brown; Sami S Zoghbi; Joseph H Krushinski; Eyassu Chernet; Johannes Tauscher; John M Schaus; Lee A Phebus; Amy K Chesterfield; Christian C Felder; Robert L Gladding; Jinsoo Hong; Christer Halldin; Victor W Pike; Robert B Innis
Journal:  Neuropsychopharmacology       Date:  2007-03-28       Impact factor: 7.853

6.  Tracer kinetic modeling of the 5-HT1A receptor ligand [carbonyl-11C]WAY-100635 for PET.

Authors:  R N Gunn; P A Sargent; C J Bench; E A Rabiner; S Osman; V W Pike; S P Hume; P M Grasby; A A Lammertsma
Journal:  Neuroimage       Date:  1998-11       Impact factor: 6.556

7.  Delta 9-tetrahydrocannabinol induces dopamine release in the human striatum.

Authors:  Matthijs G Bossong; Bart N M van Berckel; Ronald Boellaard; Lineke Zuurman; Robert C Schuit; Albert D Windhorst; Joop M A van Gerven; Nick F Ramsey; Adriaan A Lammertsma; René S Kahn
Journal:  Neuropsychopharmacology       Date:  2008-08-27       Impact factor: 7.853

8.  The use of spectral analysis to determine regional cerebral glucose utilization with positron emission tomography and [18F]fluorodeoxyglucose: theory, implementation, and optimization procedures.

Authors:  F Turkheimer; R M Moresco; G Lucignani; L Sokoloff; F Fazio; K Schmidt
Journal:  J Cereb Blood Flow Metab       Date:  1994-05       Impact factor: 6.200

9.  Automatic morphometry in Alzheimer's disease and mild cognitive impairment.

Authors:  Rolf A Heckemann; Shiva Keihaninejad; Paul Aljabar; Katherine R Gray; Casper Nielsen; Daniel Rueckert; Joseph V Hajnal; Alexander Hammers
Journal:  Neuroimage       Date:  2011-03-11       Impact factor: 6.556

10.  Balancing bias, reliability, noise properties and the need for parametric maps in quantitative ligand PET: [(11)C]diprenorphine test-retest data.

Authors:  Alexander Hammers; Marie-Claude Asselin; Federico E Turkheimer; Rainer Hinz; Safiye Osman; Gary Hotton; David J Brooks; John S Duncan; Matthias J Koepp
Journal:  Neuroimage       Date:  2007-07-24       Impact factor: 6.556

View more
  7 in total

1.  Improved models for plasma radiometabolite correction and their impact on kinetic quantification in PET studies.

Authors:  Matteo Tonietto; Mattia Veronese; Gaia Rizzo; Paolo Zanotti-Fregonara; Talakad G Lohith; Masahiro Fujita; Sami S Zoghbi; Alessandra Bertoldo
Journal:  J Cereb Blood Flow Metab       Date:  2015-04-15       Impact factor: 6.200

Review 2.  Spectral Analysis of Dynamic PET Studies: A Review of 20 Years of Method Developments and Applications.

Authors:  Mattia Veronese; Gaia Rizzo; Alessandra Bertoldo; Federico E Turkheimer
Journal:  Comput Math Methods Med       Date:  2016-12-05       Impact factor: 2.238

3.  Test-retest reproducibility of quantitative binding measures of [11C]Ro15-4513, a PET ligand for GABAA receptors containing alpha5 subunits.

Authors:  Colm J McGinnity; Daniela A Riaño Barros; Lula Rosso; Mattia Veronese; Gaia Rizzo; Alessandra Bertoldo; Rainer Hinz; Federico E Turkheimer; Matthias J Koepp; Alexander Hammers
Journal:  Neuroimage       Date:  2017-03-11       Impact factor: 6.556

4.  Αlpha 5 subunit-containing GABAA receptors in temporal lobe epilepsy with normal MRI.

Authors:  Colm J McGinnity; Daniela A Riaño Barros; Rainer Hinz; James F Myers; Siti N Yaakub; Charlotte Thyssen; Rolf A Heckemann; Jane de Tisi; John S Duncan; Josemir W Sander; Anne Lingford-Hughes; Matthias J Koepp; Alexander Hammers
Journal:  Brain Commun       Date:  2021-01-07

Review 5.  Advances of Molecular Imaging in Epilepsy.

Authors:  Marian Galovic; Matthias Koepp
Journal:  Curr Neurol Neurosci Rep       Date:  2016-06       Impact factor: 5.081

6.  Acute induction of anxiety in humans by delta-9-tetrahydrocannabinol related to amygdalar cannabinoid-1 (CB1) receptors.

Authors:  Sagnik Bhattacharyya; Alice Egerton; Euitae Kim; Lula Rosso; Daniela Riano Barros; Alexander Hammers; Michael Brammer; Federico E Turkheimer; Oliver D Howes; Philip McGuire
Journal:  Sci Rep       Date:  2017-11-03       Impact factor: 4.379

7.  Association between cannabinoid 1 receptor availability and glutamate levels in healthy controls and drug-free patients with first episode psychosis: a multi-modal PET and 1H-MRS study.

Authors:  Faith Borgan; Mattia Veronese; Tiago Reis Marques; David J Lythgoe; Oliver Howes
Journal:  Eur Arch Psychiatry Clin Neurosci       Date:  2020-09-28       Impact factor: 5.270

  7 in total