Literature DB >> 24732603

Total internal reflection (TIRF)-based quantification of procalcitonin for sepsis diagnosis--a point-of-care testing application.

Daniela Rascher1, Arie Geerlof2, Elisabeth Kremmer3, Petra Krämer1, Schmid Michael1, Anton Hartmann1, Martin Rieger4.   

Abstract

A new, highly sensitive fluorescence immunoassay for a TIRF (total internal reflection)-based point-of-care testing (POCT) device was developed for the detection of procalcitonin (PCT), a specific and early marker for sepsis and microbial infections. The immunoassay was performed on a bench-top system that fulfilled all the necessary characteristics of a POCT application, including a short measurement time (<9 min), no sample pre-treatment requirements and application directly near patients. New rat monoclonal antibodies targeting PCT were screened and characterized. The best combinations of antibodies were then integrated into single-use cartridges, and the reduction of nonspecific binding was achieved by supplying suitable additives. Moreover, human recombinant PCT (hrPCT) for use as a standard was developed in the native form of hPCT in plasma (PCT1-116, PCT3-116). The assay achieves the required sensitivity range in human plasma to allow reliable differentiation between healthy persons and varying stages of infection severity (LOD=0.04 ng/mL; LOQ=0.12 ng/mL). Furthermore, the developed PCT assay can be applied in whole human blood with an adequate sensitivity (LOD=0.02 ng/mL; LOQ=0.09 ng/mL). To the best of our knowledge, this is the first diagnostic test for sepsis to use whole blood, which is a crucial requirement for POCT. We were able to detect native PCT in patient samples and showed a good correlation (R(2)=0.988) with the results of the Kryptor(®) device from BRAHMS, a state of the art device for the detection of PCT.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Evanescent field; FIA; POCT; Sepsis; Tirf; hrPCT

Mesh:

Substances:

Year:  2014        PMID: 24732603     DOI: 10.1016/j.bios.2014.03.052

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Point of care technologies for sepsis diagnosis and treatment.

Authors:  Taylor Oeschger; Duncan McCloskey; Varun Kopparthy; Ankur Singh; David Erickson
Journal:  Lab Chip       Date:  2019-02-26       Impact factor: 6.799

Review 2.  Evanescent wave fluorescence biosensors: Advances of the last decade.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2015-07-20       Impact factor: 10.618

3.  Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein.

Authors:  XiaoPing Qi; YunYe Huang; ZhongShi Lin; Liang Xu; Hao Yu
Journal:  Nanoscale Res Lett       Date:  2016-03-25       Impact factor: 4.703

4.  Analytical evaluation of a BNP assay on the new point-of-care platform respons®IQ.

Authors:  Stephan Fellner; Simone Hentze; Uwe Kempin; Evelyn Richter; Jörg Rocktäschel; Barbara Langer
Journal:  Pract Lab Med       Date:  2015-05-01

5.  Guiding Effect of Serum Procalcitonin (PCT) on the Antibiotic Application to Patients with Sepsis.

Authors:  Yu Liu; Weize Yang; Jie Wei
Journal:  Iran J Public Health       Date:  2017-11       Impact factor: 1.429

6.  Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis.

Authors:  Águeda Molinero-Fernández; María Moreno-Guzmán; Miguel Ángel López; Alberto Escarpa
Journal:  Biosensors (Basel)       Date:  2020-06-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.