Literature DB >> 24727361

Database of normalised computed tomography dose index for retrospective CT dosimetry.

Eunah Lee1, Stephanie Lamart, Mark P Little, Choonsik Lee.   

Abstract

Volumetric computed tomography dose index (CTDIvol) is an important dose descriptor to reconstruct organ doses for patients combined with the organ dose calculated from computational human phantoms coupled with Monte Carlo transport techniques. CTDIvol can be derived from weighted CTDI (CTDIw) normalised to the tube current-time product (mGy/100 mAs), using knowledge of tube current-time product (mAs), tube potential (kVp), type of CTDI phantoms (head or body), and pitch. The normalised CTDIw is one of the characteristics of a CT scanner but not readily available from the literature. In the current study, we established a comprehensive database of normalised CTDIw values based on multiple data sources: the ImPACT dose survey from the United Kingdom, the CT-Expo dose calculation program, and surveys performed by the US Food and Drug Administration (FDA) and the National Lung Screening Trial (NLST). From the sources, the CTDIw values for a total of 68, 138, 30, and 13 scanner model groups were collected, respectively. The different scanner groups from the four data sources were sorted and merged into 162 scanner groups for eight manufacturers including General Electric (GE), Siemens, Philips, Toshiba, Elscint, Picker, Shimadzu, and Hitachi. To fill in missing CTDI values, a method based on exponential regression analysis was developed based on the existing data. Once the database was completed, two different analyses of data variability were performed. First, we averaged CTDI values for each scanner in the different data sources and analysed the variability of the average CTDI values across the different scanner models within a given manufacturer. Among the four major manufacturers, Toshiba and Philips showed the greatest coefficient of variation (COV) (=standard deviation/mean) for the head and body normalised CTDIw values, 39% and 54%, respectively. Second, the variation across the different data sources was analysed for CT scanners where more than two data sources were involved. The CTDI values for the scanners from Siemens showed the greatest variation across the data sources, being about four times greater than the variation of Toshiba scanners. The established CTDI database will be used for the reconstruction of CTDIvol and then the estimation of individualised organ doses for retrospective patient cohorts in epidemiologic studies.

Entities:  

Mesh:

Year:  2014        PMID: 24727361     DOI: 10.1088/0952-4746/34/2/363

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  6 in total

1.  Reduction in radiation doses from paediatric CT scans in Great Britain.

Authors:  Choonsik Lee; Mark S Pearce; Jane A Salotti; Richard W Harbron; Mark P Little; Kieran McHugh; Claire-Louise Chapple; Amy Berrington de Gonzalez
Journal:  Br J Radiol       Date:  2016-02-11       Impact factor: 3.039

2.  ORGAN DOSE ESTIMATION ACCOUNTING FOR UNCERTAINTY FOR PEDIATRIC AND YOUNG ADULT CT SCANS IN THE UNITED KINGDOM.

Authors:  Choonsik Lee; Neige Journy; Brian E Moroz; Mark Little; Richard Harbron; Kieran McHugh; Mark Pearce; Amy Berrington de Gonzalez
Journal:  Radiat Prot Dosimetry       Date:  2019-07-01       Impact factor: 0.972

3.  Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations.

Authors:  Amir Bahadori; Diana Miglioretti; Randell Kruger; Michael Flynn; Sheila Weinmann; Rebecca Smith-Bindman; Choonsik Lee
Journal:  AJR Am J Roentgenol       Date:  2015-10       Impact factor: 3.959

4.  Individual radiation exposure from computed tomography: a survey of paediatric practice in French university hospitals, 2010-2013.

Authors:  Neige M Y Journy; Serge Dreuil; Nathalie Boddaert; Jean-François Chateil; Didier Defez; Hubert Ducou-le-Pointe; Jean-Marc Garcier; Joël Guersen; Bouchra Habib Geryes; Andreas Jahnen; Choonsik Lee; Jacqueline Payen-de-la-Garanderie; Jean-Pierre Pracros; Dominique Sirinelli; Isabelle Thierry-Chef; Marie-Odile Bernier
Journal:  Eur Radiol       Date:  2017-08-23       Impact factor: 5.315

5.  Reconstruction of paediatric organ doses from axial CT scans performed in the 1990s - range of doses as input to uncertainty estimates.

Authors:  Hilde M Olerud; Benthe Toft; Silje Flatabø; Andreas Jahnen; Choonsik Lee; Isabelle Thierry-Chef
Journal:  Eur Radiol       Date:  2016-01-23       Impact factor: 5.315

6.  Establishment of diagnostic reference levels in cardiac computed tomography.

Authors:  Mohammad Rawashdeh; Charbel Saade; Maha Zaitoun; Mostafa Abdelrahman; Patrick Brennan; Haytham Alewaidat; Mark F McEntee
Journal:  J Appl Clin Med Phys       Date:  2019-08-30       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.