Literature DB >> 24724129

Microleakage of Posterior Composite Restorations with Fiber Inserts Using two Adhesives after ging.

F Sharafeddin1, H Yousefi2, Sh Modiri3, A Tondari3, Sr Safaee Jahromi4.   

Abstract

STATEMENT OF PROBLEM: Microleakage is one of the most frequent problems associated with resin composites, especially at the gingival margin of posterior restorations. Insertion of fibers in composite restorations can reduce the total amount of composite and help to decrease the shrinkage.
PURPOSE: The aim of this study was to evaluate the effect of polyethylene fiber inserts on gingival microleakage of class II composite restorations using two different adhesive systems. MATERIALS AND
METHOD: In this experimental study, class II cavities were prepared on 60 premolars. The gingival floor was located 1.0 mm below the CEJ. Dimension of each cavity were 3 mm buccolingually and 1.5 mm in axial depth. The specimens were divided into 4 groups according to the adhesive type and fiber insert (n=4). Single bond and Clearfill SE bond and Filtek p60 were used to restore the cavities. In groups without fiber inserts composite was adapted onto cavities using layering technique. For cavities with fiber inserts, 3 mm piece of fiber insert was placed onto the composite increment and cured. The specimens were stored in distilled water at 37(o)C for 6 months. All specimens were subjected to 3000 thermo-cycling. The tooth surfaces except for 1 mm around the restoration margins covered with two layers of nail varnish .The teeth were immersed in 2% Basic Fuchsin for 24 hours, then rinsed and sectioned mesiodistally. The microleakage was determined under a stereomicroscope (40X). Data were statistically analyzed by Kruskal-wallis and Mann-Whitney U tests (p< 0.05).
RESULTS: The Kruskal-Wallis test revealed no significant differences in mean microleakage scores among all groups (p= 0.281).
CONCLUSION: Use of polyethylene fiber inserts and etch-and-rinse and self-etch adhesives had no effect on microleakage in class II resin composite restorations with gingival margins below the CEJ after 6- month water storage.

Entities:  

Keywords:  Composite restorations; Microleakage; Polyethylene fiber

Year:  2013        PMID: 24724129      PMCID: PMC3927678     

Source DB:  PubMed          Journal:  J Dent (Shiraz)        ISSN: 2345-6418


Introduction

Glass and polyethylene fibers are used as reinforcing agent in composite restorations [1-2]. Currently, light cure resin composites are widely used to restore posterior teeth due to their esthetic properties and their ad- hesion to tooth structures [3-4]. Microleakage is one of the most frequent encountered problems, especially at the gingival margin of class II restorations [5-6]. Microleakage may lead to postoperative sensitivity, recurrent caries, marginal deterioration, pulp injury and enamel fracture [7]. Less polymerization shrinkage can be obtained if the total amount of composite material for restoration of a class II cavity is reduced [8]. Furthermore, different methods such as reducing the composite polymerization rate, using the incremental placement technique and reducing the C-factor have been suggested to decrease the microleakage of resin composite materials [5, 8]. Reinforcement of resin with fiber glass has improved mechanical and physical properties of resin composite materials [9]. To improve the mechanical properties of dental materials , new dental products such as glass , polyethylene ,quartz , carbon and other fibers have been made available recently [8]. Fiber-reinforced composites have a wide range of application such as periodontal splints and fixed partial dentures in dentistry [10]. High modulus of elasticity and low flexural modulus of polyethylene fibers modify the interfacial stresses developed along the etched enamel- resin boundary [11]. Inserting of polyethylene fibers in composite restoration can reduce the total amount of resin matrix required for restoration and decrease the shrinkage and microleakage [5, 8]. The aim of this study was to evaluate the effect of polyethylene fiber inserts on gingival microleakage of class II resin composite restorations by using two different bonding systems.

Materials and Method

The manufacturers and the composition of the material used in current study are shown in table 1.
Table 1

Products used in this study

Products Compositions Manufacturer
Filtek p60Triethylenglycol dimethacrylate, urethane dimethacrylate, silica, zirconium bisphenylethylenemethacrylate 84.5%, 0.6 mm3M ESPE Dental product
Single bondEtching gel: phosphoric acid (35%), colloidal silica thickener, color, water3M ESPE Dental product
Adhesive: polyalkenoic acid, hydroxyrthylmethacrylate, bisphenol A diglycidyl ether dimethacrylate, dimethacrylate copolymer, ethanol, water
Clearfil SE bondPrimer: hydroxyethylmethacrylate, methacryloloyloxydecyl dihydrogen phosohate, hydrophilic dimethacrylate, DL-camphorquinone, N-diethanol-p-toluidine, water3M ESPE Dental product
Adhesive: hydroxyethylmethacrylate,bisphenyl glycidylmethacrylate, methacryloloyoxydeyl dihydrogen phosphate, hydrophilic dimethacrylate, DL-camphorquinone, N-diethanol-p-toluidine, silinated colloidal silica (10 % ,microthin)
Ribbond- THM Polyethylene fiberRibbond-THM
ResistBis-GMA,alkali-soluble polymers,fluorinated ester-containing unitsbTd
In this experimental study, 60 intact human premolars were cleaned with periodontal scalers and rotary brushes. The teeth were then mounted in acrylic bases, up to 2mm apical to the CEJ. Then class II slot cavities were prepared on both proximal sides of each premolars using a 245 tungsten carbide bur (SS White; Great White Series, LAKEOOD, NJ, USA) in a water-cooled high-speed air turbine handpiece .All line angles were rounded. The gingival floor of the slot cavities was located at least 1.0 mm below the CEJ on the root surface. Each slot was 3 mm buccolingually wide and 1.5 mm in axial depth (Figure 1). The dimension of the cavities were verified with a periodontal probe. The teeth were randomly divided into 4 groups (n=4).
Figure 1

Premolars with completed slot preparation

Premolars with completed slot preparation A universal metal matrix band/retainer (Tofflemire) was placed around each prepared tooth. Each cavity was cleaned with water spay and air-dried. The bonding agent assigned to each group were applied according to manufacturer’s instructions (Table 1). A posterior resin composite (Filtek p60; shade A2, 3M ESPE) was used to restore all cavities. The specimens were divided into 4 groups according to the adhesive type and fiber insert (Table 2). The cavities without fiber inserts were used as controls .An approximate 2 mm- layer of p60 was adapted onto gingival floor and light activated for 40 seconds, using a halogen curing unit (400 mW/cm2; Unicorn Med., Korea). A second layer was added diagonally on one side and light polymerized for 40 seconds. Two other increments, filling the remainder of the box, were placed and similarly light polymerized.
Table 2

Distribution of the experimental groups among the two bonding agent and fiber insertion

Groups Bonding agent Fiber insert
G1Single bond--------
G2Single bondPolyethylene fiber
G3Clearfil SE bond--------
G4Clearfil SE bondPolyethylene fiber
Products used in this study Distribution of the experimental groups among the two bonding agent and fiber insertion For cavities with fiber inserts, a less than 1- mm- thick resin composite was first placed on the gingival floor. Then, a 3- mm piece of fiber insert was preimpre-gnated in Resist (NSI Dental Pty Ltd; Australia) for 5 minutes and then placed onto the composite increment and condensed through it to be adapted against the gingival floor and light-polymerized for 40 seconds from the occlusal aspect. Three other diagonal layers of resin composite were placed and polymerized as stated previously. Only the occlusal surfaces were then finished with 30-bladed tungsten carbide bur (H 135 UF, H 379 UF. H 246 LUF; Brasseler, USA) in a high-speed handpiece with water cooling. Polishing was performed afterwards by an aluminum oxide point (Jiffy points; Ultradent).the specimens were then stored in distilled water at 37 0C for 6 months in an incubator (Behdad; Iran). All specimens were then subjected to 3000 thermo-cycling between 5 0C and 55 0C in water bath (SANAF; Iran) with dwell time of 30 seconds. Tooth surfaces except for 1mm around the restoration margins were covered with two layers of nail varnish. The teeth were then immersed in 2% Basic Fuchsin for 24 hours, then rinsed in tap water for 5 minutes. Then each tooth was sectioned mesiodistally with a high-speed diamond saw (Isomet; buchler, USA). The section with deepest penetration was selected to be reported in our study. Microleakage was determined blindly by three observers under a stereomicroscope with 40X magnification according to a six-point scale: 0= no leakage 1= leakage extending to the outer half of the gingival floor 2= leakage extending to the inner half of the gingival floor 3= leakage extending through gingival floor up to 1/3 of the axial wall 4=leakage extending through gingival floor up to 2/3 of the axial wall 5=leakage extending through the gingival wall up to the DEJ level Data were statistically analyzed by non-parametric Kruskal-Wallis test and Mann-Whitney U test (p< 0.05).

Results

The mean and standard deviation of microleakage scor-es for all groups are presented in table 3 and figure 2.
Table 3

Microleakage scores distribution among the test groups with means and standard deviations

Groups Microleakage scale
Mean SD
Percent
0 1 2 3 4 5
Adper single bondG17800000.730.799
46.7%53.5%0.0%0.0%0.0%0.0%
G29600000.470.640
60.0%40.0%0.0%0.0%0.0%0.0%
Clearfil SE bondG38700000.530.640
53.3%46.7&0.0%0.0%0.0%0.0%
G412300000.270.594
80.0%20.0%0.0%0.0%0.0%0.0%

G1: Single bond           G2: Single bond + polyethylene fiber           G3: Clearfil SE bond          G4: Clearfil SE bond + polyethylene fiber

Figure 2

Mean of microleakage

Mean of microleakage G1: Single bond G2: Single bond + polyethylene fiber G3: Clearfil SE bond G4: Clearfil SE bond + polyethylene fiber Microleakage scores distribution among the test groups with means and standard deviations G1: Single bond           G2: Single bond + polyethylene fiber           G3: Clearfil SE bond          G4: Clearfil SE bond + polyethylene fiber The Kruskal-Wallis test revealed no significant differences in mean microleakage scores among the groups (p= 0.281). Mann-Whitney test showed that Group 1 had higher microleakage scores than the Group 2, but this different was not significant (p= 0.412). Group 4 had lower scores than group 2 but this difference was not statistically significant (p= 0.278). Group 3 had higher scores in terms of microleakage but it was not statistically significant (p= 0.161). Group 1 had higher microleakage than group 3, but again this difference was not statistically significant (p= 0.102). Generally, specimens from the groups with polyethylene fiber inserts had lower scores than the groups without inserts, but this difference was not statistically significant. Clearfil SE bond produced the lower degree of microleakage than those with Adper single bond application, but these differences were not statistically significant. The lowest microleakage scores belonged to group 4 (Clearfil SE bond) and the highest scores were seen in group 1 (Adper single bond) but it was not statistically significant.

Discussion

One of the most important clinical drawbacks of the resin composite restorative materials is their marginal microleakage [12]; which occurs as a result of polymerization shrinkage, fatigue-cycling, thermal changes in oral environment [13]. Fibers have been added to resin composites to solve this problem by reducing the total amount of composite and increasing the resistance of initial composite increment against pull- away from the gingival margin toward the light curing unit [4, 8, 14]. In the current study groups, polyethylene fiber inserts did not show significant reduction in microleakage. This finding is in contrast with some previous studies, suggesting that fiber insertion could reduce marginal microleakage [4-5, 8]. This finding can be related to the layering technique that was used in the current study. It has been reported that glass fibers were more effective than polyethylene fibers for reinforcement due to their good adhesion to the resin matrix [14].However, in our study, we used only polyethylene fiber that was as effective as composite restorations without fiber inserts. Another approach to improve marginal integrity and consequent clinical problems is the use of lining materials with low viscosity such as glass ionomers or some types of bonding agents [15-16]. We used one layer of composite at the base of restorations in gingival floor which could reduce the polymerization shrinkage, occurring in bulk technique restorations at the base of box on gingival floor [17]. In the current study; two adhesive systems (two-step etch-and-rinse and one mild self-etching primer) were used to evaluate the effect of type of bonding agent on marginal microleakage. The bonding mechanism of these two systems is quite different [18]. The bonding mechanism of etch-and-rinse system is diffusion-based, the way of resin infiltrates into collagen fibrils and forms hybrid layer via micromechanical bonding [19]. In self-etching system, the bonding mechanism is based on the dissolution of the smear layer and penetration of acidic monomers in underlying dentin which leads to the hybrid layer formation [20]. In mild self-etching adhesive systems, some hydroxyapatite remain around the collagen fibrils caused by low acidity of monomers and may have chemical reaction with functional monomer in addition to micromechanical retention which can reduce marginal microleakage [18]. The results of this study showed that these two bonding systems have similar sealing ability in the margins of restorations, which is consistent with some previous researches [20-22]. There are different methods to evaluate microleakage, such as scanning electron microscopy, electro-chemical studies and dye penetration [23-24]. Dye penetration, a semi-quantitative method, was used in current study. Some studies have reported that there was no difference between these methods regarding the evaluation of microleakage [18, 20]. In the current study, all specimens were stored in water for 6 months which was different from previous studies that evaluated microleakage of class II composite restoration with fiber insert. One study showed that 3- month- storage had no effect on microleakage [25] but some other studies concluded that storage time increases the microleakage in some bonding systems [26-28]. It seems that fiber insertion or application of different bonding systems have no effect on the gingival microleakage of class II resin composite restorations after 6 months of storage .It may be due to the equal hybridization of self- etch and total- etch adhesives after 6 months. Therefore,the microleakage of restorations with or without fiber was equal. In this study, we evaluated microleakage of gingival margins because most previous studies reported that the microleakage of gingival margins in composite restorations was more than the microleakage of occlusal margins [3-4]. Bleaching agent may affect the physical and mechanical properties of composite resins [29]. Glass fibers and low- shrinkage composites, like silorane-based composite, can also be evaluated, as a suggestion for future studies, to reduce the marginal microleakage of fiber reinforced composite restorations, by employing different techniques and evaluation in different media.

Conclusion

Within the limitation of the current in vitro study it can be stated that: The use of polyethylene fiber inserts have no effect on microleakage in class II resin composite restorations with gingival margins below the cemento-enamel junction after 6- month-storage in water There is no difference between two bonding systems (two-step etch-and-rinse and self-etching primer) in marginal microleakage in class II composite restorations after 6-month-storage in water.
  24 in total

1.  The effect of flexural load cycling on the microleakage of cervical resin composites.

Authors:  S Kubo; H Yokota; Y Sata; Y Hayashi
Journal:  Oper Dent       Date:  2001 Sep-Oct       Impact factor: 2.440

2.  Influence of load cycling on marginal microleakage with two self-etching and two one-bottle dentin adhesive systems in dentin.

Authors:  Fabio Hiroyuki Ogata Mitsui; Ana Karina Barbieri Bedran-de-Castro; André Vicente Ritter; Paulo Eduardo Capel Cardoso; Luiz André Freire Pimenta
Journal:  J Adhes Dent       Date:  2003       Impact factor: 2.359

3.  The effect of long-term storage on the microleakage of composite resin restorations: qualitative and quantitative evaluation.

Authors:  Fernanda Tranchesi Sadek; Sandra Kiss Moura; Rafael Yagüe Ballester; Antonio Muench; Paulo Eduardo Capel Cardoso
Journal:  Pesqui Odontol Bras       Date:  2003-12-16

4.  In vitro examination of the fracture strength of 3 different fiber-reinforced composite and 1 all-ceramic posterior inlay fixed partial denture systems.

Authors:  Carola Kolbeck; Martin Rosentritt; Michael Behr; Reinhold Lang; Gerhard Handel
Journal:  J Prosthodont       Date:  2002-12       Impact factor: 2.752

5.  Evaluation of microleakage of composite resin restorations by an electrochemical technique: the impedance methodology.

Authors:  Nelly Pradelle-Plasse; François Wenger; Bernard Picard; Pierre Colon
Journal:  Dent Mater       Date:  2004-06       Impact factor: 5.304

Review 6.  Dental adhesion review: aging and stability of the bonded interface.

Authors:  Lorenzo Breschi; Annalisa Mazzoni; Alessandra Ruggeri; Milena Cadenaro; Roberto Di Lenarda; Elettra De Stefano Dorigo
Journal:  Dent Mater       Date:  2007-04-17       Impact factor: 5.304

7.  Effect of fiber nets, application techniques and flowable composites on microleakage and the effect of fiber nets on polymerization shrinkage in class II MOD cavities.

Authors:  Emre Ozel; Mubin Soyman
Journal:  Oper Dent       Date:  2009 Mar-Apr       Impact factor: 2.440

8.  In vitro comparison of microleakage of posterior resin composites with and without liner using two-step etch-and-rinse and self-etch dentin adhesive systems.

Authors:  Shahin Kasraei; Mohadese Azarsina; Somayeh Majidi
Journal:  Oper Dent       Date:  2011-06-24       Impact factor: 2.440

9.  The effect of c-factor and flowable resin or fiber use at the interface on microtensile bond strength to dentin.

Authors:  Sema Belli; Nazmiye Dönmez; Gürcan Eskitaşcioğlu
Journal:  J Adhes Dent       Date:  2006-08       Impact factor: 2.359

10.  Polymerization shrinkage of experimental short glass fiber-reinforced composite with semi-inter penetrating polymer network matrix.

Authors:  Sufyan Garoushi; Pekka K Vallittu; David C Watts; Lippo V J Lassila
Journal:  Dent Mater       Date:  2007-05-24       Impact factor: 5.304

View more
  7 in total

1.  The Effect of Temperature on Shear Bond Strength of Clearfil SE Bond and Adper Single Bond Adhesive Systems to Dentin.

Authors:  Farahnaz Sharafeddin; Hossein Nouri; Fatemeh Koohpeima
Journal:  J Dent (Shiraz)       Date:  2015-03

2.  Assessment of the Shear Bond Strength between Nanofilled Composite Bonded to Glass-ionomer Cement Using Self-etch Adhesive with Different pHs and Total-Etch Adhesive.

Authors:  Farahnaz Sharafeddin; Mohammad Mehdi Choobineh
Journal:  J Dent (Shiraz)       Date:  2016-03

3.  Effect of Dimethyl Sulfoxide on Bond Strength of a Self-Etch Primer and an Etch and Rinse Adhesive to Surface and Deep Dentin.

Authors:  Farahnaz Sharafeddin; Raha Salehi; Negar Feizi
Journal:  J Dent (Shiraz)       Date:  2016-09

4.  Marginal Micro-leakage of Self-etch and All-in One Adhesives to Primary Teeth, with Mechanical or Chemo-Mechanical Caries Removal.

Authors:  Nouzari A; Zohrei A; Ferooz M; Mohammadi N
Journal:  J Dent Biomater       Date:  2016-06

5.  The effect of short polyethylene fiber with different weight percentages on diametral tensile strength of conventional and resin modified glass ionomer cements.

Authors:  Farahnaz Sharafeddin; Seyed-Ali Ghaboos; Zahra Jowkar
Journal:  J Clin Exp Dent       Date:  2017-03-01

6.  Effect of Contamination with Hemostatic Agent on Shear Bond Strength of Composite to Dentin Using G-Premio and Single Bond Universal Adhesives.

Authors:  Zahra Khamverdi; Naemeh Karimian; Maryam Farhadian; Hamed Gheitouli
Journal:  Front Dent       Date:  2021-07-25

7.  Evaluation of Shear Bond Strength of Total- and Self-etching Adhesive Systems after Application of Chlorhexidine to Dentin Contaminated with a Hemostatic Agent.

Authors:  Farahnaz Sharafeddin; Hajar Farhadpour
Journal:  J Dent (Shiraz)       Date:  2015-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.