Literature DB >> 24721227

Detection of Plasmodium vivax and Plasmodium falciparum DNA in human saliva and urine: loop-mediated isothermal amplification for malaria diagnosis.

Zahra Ghayour Najafabadi1, Hormozd Oormazdi1, Lame Akhlaghi1, Ahmad Reza Meamar1, Mehdi Nateghpour2, Leila Farivar2, Elham Razmjou3.   

Abstract

This study investigated loop-mediated isothermal amplification (LAMP) detection of Plasmodium falciparum and Plasmodium vivax in urine and saliva of malaria patients. From May to November 2011, 108 febrile patients referred to health centers in Sistan and Baluchestan Province of south-eastern Iran participated in the study. Saliva, urine, and blood samples were analyzed with nested PCR and LAMP targeting the species-specific nucleotide sequence of small subunit ribosomal RNA gene (18S rRNA) of P. falciparum and P. vivax and evaluated for diagnostic accuracy by comparison to blood nested PCR assay. When nested PCR of blood is used as standard, microscopy and nested PCR of saliva and urine samples showed sensitivity of 97.2%, 89.4% and 71% and specificity of 100%, 97.3% and 100%, respectively. LAMP sensitivity of blood, saliva, and urine was 95.8%, 47% and 29%, respectively, whereas LAMP specificity of these samples was 100%. Microscopy and nested PCR of saliva and LAMP of blood were comparable to nested PCR of blood (к=0.95, 0.83, and 0.94, respectively), but agreement for nested PCR of urine was moderate (к=0.64) and poor to fair for saliva LAMP and urine LAMP (к=0.38 and 0.23, respectively). LAMP assay showed low sensitivity for detection of Plasmodium DNA in human saliva and urine compared to results with blood and to nested PCR of blood, saliva, and urine. However, considering the advantages of LAMP technology and of saliva and urine sampling, further research into the method is worthwhile. LAMP protocol and precise preparation protocols need to be defined and optimized for template DNA of saliva and urine.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  LAMP; Malaria diagnosis; P. falciparum; Plasmodium vivax; Saliva; Urine

Mesh:

Substances:

Year:  2014        PMID: 24721227     DOI: 10.1016/j.actatropica.2014.03.029

Source DB:  PubMed          Journal:  Acta Trop        ISSN: 0001-706X            Impact factor:   3.112


  13 in total

1.  Plasmodium knowlesi detection methods for human infections-Diagnosis and surveillance.

Authors:  Matthew J Grigg; Inke N Lubis; Kevin K A Tetteh; Bridget E Barber; Timothy William; Giri S Rajahram; Angelica F Tan; Colin J Sutherland; Rintis Noviyanti; Chris J Drakeley; Sumudu Britton; Nicholas M Anstey
Journal:  Adv Parasitol       Date:  2021-09-17       Impact factor: 3.125

2.  Development of Visually Improved Loop Mediated Isothermal Amplification for the Diagnosis of Plasmodium vivax Malaria in a Tertiary Hospital in Chandigarh, North India.

Authors:  Hargobinder Kaur; Rakesh Sehgal; Devendra Bansal; Ali A Sultan; Ashish Bhalla; Sunit C Singhi
Journal:  Am J Trop Med Hyg       Date:  2018-03-15       Impact factor: 2.345

3.  Detection of the Malaria causing Plasmodium Parasite in Saliva from Infected Patients using Topoisomerase I Activity as a Biomarker.

Authors:  Marianne Smedegaard Hede; Søren Fjelstrup; Felix Lötsch; Rella Manego Zoleko; Anna Klicpera; Mirjam Groger; Johannes Mischlinger; Lilian Endame; Luzia Veletzky; Ronja Neher; Anne Katrine Wrist Simonsen; Eskild Petersen; Ghyslain Mombo-Ngoma; Magnus Stougaard; Yi-Ping Ho; Rodrigo Labouriau; Michael Ramharter; Birgitta Ruth Knudsen
Journal:  Sci Rep       Date:  2018-03-07       Impact factor: 4.379

4.  Poor Diagnostic Performance of a Species-Specific Loop-Mediated Isothermal Amplification (LAMP) Platform for Malaria.

Authors:  Hans Kollenda; Ralf Matthias Hagen; Miriam Hanke; Sandra Rojak; Rebecca Hinz; Lars Wassill; Sven Poppert; Egbert Tannich; Hagen Frickmann
Journal:  Eur J Microbiol Immunol (Bp)       Date:  2018-09-28

5.  Accuracy of malaria diagnostic tests performed on non-invasively collected samples: a systematic review and meta-analysis.

Authors:  Celestin Danwang; Jean Jacques Noubiap; Jacob Souopgui; Jean Gaudart; Jean Cyr Yombi; Annie Robert
Journal:  BMJ Glob Health       Date:  2021-06

6.  Field Evaluation of Malaria Microscopy, Rapid Malaria Tests and Loop-Mediated Isothermal Amplification in a Rural Hospital in South Western Ethiopia.

Authors:  Juan Cuadros; Ramón Pérez-Tanoira; Laura Prieto-Pérez; Ines Martin-Martin; Pedro Berzosa; Vicenta González; Gebre Tisiano; Seble Balcha; José Manuel Ramos; Miguel Górgolas
Journal:  PLoS One       Date:  2015-11-10       Impact factor: 3.240

7.  Rapid Point-of-Care Isothermal Amplification Assay for the Detection of Malaria without Nucleic Acid Purification.

Authors:  Sayli S Modak; Cheryl A Barber; Eran Geva; William R Abrams; Daniel Malamud; Yhombi Serge Yvon Ongagna
Journal:  Infect Dis (Auckl)       Date:  2016-01-20

8.  Detection of Plasmodium falciparum DNA in saliva samples stored at room temperature: potential for a non-invasive saliva-based diagnostic test for malaria.

Authors:  Kenji O Mfuh; Samuel Tassi Yunga; Livo F Esemu; Obase Ngemani Bekindaka; Jessica Yonga; Jean Claude Djontu; Calixt D Mbakop; Diane W Taylor; Vivek R Nerurkar; Rose G F Leke
Journal:  Malar J       Date:  2017-10-27       Impact factor: 2.979

9.  Comprehensive characterization of plasma cell-free Echinococcus spp. DNA in echinococcosis patients using ultra-high-throughput sequencing.

Authors:  Jingkai Ji; Bin Li; Jingzhong Li; Wangmu Danzeng; Jiandong Li; Yanping Zhao; Gezhen Qiangba; Qingda Zhang; Nibu Renzhen; Zhuoga Basang; Changlin Jia; Quzhen Gongsang; Jinmin Ma; Yicong Wang; Fang Chen; Hongcheng Zhou; Jiefang Yin; Jiandan Xie; Na Pei; Huimin Cai; Huayan Jiang; Huanming Yang; Jian Wang; Xiumin Han; Junhua Li; Weijun Chen; Dong Yang
Journal:  PLoS Negl Trop Dis       Date:  2020-04-13

10.  Detection and genetic characterization of Echinococcus granulosus mitochondrial DNA in serum and formalin-fixed paraffin embedded cyst tissue samples of cystic echinococcosis patients.

Authors:  Maryam Moradi; Ahmad Reza Meamar; Lame Akhlaghi; Mona Roozbehani; Elham Razmjou
Journal:  PLoS One       Date:  2019-10-29       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.