OBJECTIVES: Because posterior cruciate ligament (PCL) resection makes flexion gaps wider in total knee replacement (TKR), preserving or sacrificing a PCL affects the gap equivalence; however, there are no criteria for the PCL resection that consider gap situations of each knee. This study aims to investigate gap characteristics of knees and to consider the criteria for PCL resection. METHODS: The extension and flexion gaps were measured, first with the PCL preserved and subsequently with the PCL removed (in cases in which posterior substitute components were selected). The PCL preservation or sacrifice was solely determined by the gap measurement results, without considering other functions of the PCL such as 'roll back.' RESULTS: Wide variations were observed in the extension and flexion gaps. The flexion gaps were significantly larger than the extension gaps. Cases with 18 mm or more flexion gap and with larger flexion than extension gap were implanted with cruciate retaining component. A posterior substitute component was implanted with the other cases. CONCLUSIONS: In order to make adequate gaps, it is important to decide whether to preserve the PCL based on the intra-operative gap measurements made with the PCL intact. Cite this article: Bone Joint Res 2014;3:95-100.
OBJECTIVES: Because posterior cruciate ligament (PCL) resection makes flexion gaps wider in total knee replacement (TKR), preserving or sacrificing a PCL affects the gap equivalence; however, there are no criteria for the PCL resection that consider gap situations of each knee. This study aims to investigate gap characteristics of knees and to consider the criteria for PCL resection. METHODS: The extension and flexion gaps were measured, first with the PCL preserved and subsequently with the PCL removed (in cases in which posterior substitute components were selected). The PCL preservation or sacrifice was solely determined by the gap measurement results, without considering other functions of the PCL such as 'roll back.' RESULTS: Wide variations were observed in the extension and flexion gaps. The flexion gaps were significantly larger than the extension gaps. Cases with 18 mm or more flexion gap and with larger flexion than extension gap were implanted with cruciate retaining component. A posterior substitute component was implanted with the other cases. CONCLUSIONS: In order to make adequate gaps, it is important to decide whether to preserve the PCL based on the intra-operative gap measurements made with the PCL intact. Cite this article: Bone Joint Res 2014;3:95-100.
The methodology to make equal gaps in knee extension and flexion
has not been established in total knee replacement.Because PCL resection makes flexion gaps wider, preserving or
sacrificing a PCL affects the gap equivalence.There are no criteria for PCL resection that consider gap situations
of each knee.
Key messages
Both extension and flexion gaps showed too wide a variation to
predict before operations.Flexion gaps were bigger than extension gaps in almost all cases
and the difference between the two gaps also showed wide variation.PCL resection in all cases may cause severe gap imbalance between
knee extension and flexion.Intra-operative gap measurement with PCL preservation is important
to understand the characteristics of each knee.This is the first report criteria concerning PCL preservation
or sacrifice which considers gap situations in each knee.Limitation: measurement method reliability and validity are unknown.
Introduction
Total knee replacement (TKR) is widely available, and there are
two main types of component design: posterior cruciate ligament
(PCL) preserving or substitute. Both cruciate retaining (CR) and
posterior substitute (PS) components have been reported to have
good clinical results.[1-5]The difference
between CR and PS components regarding PCL function usually concerns
posterior roll back during knee bending.[6,7] The
CR component was expected to produce the roll back as a remaining
PCL function; however, some fluoroscopic movement analysis studies revealed paradoxical
anterior movement in CR TKR,[8,9] while the PS component
drives the constant roll back function through the post/cam mechanism.[6] Some authors have
reported that when the PCL, a strong stabiliser of the knee joint,
is resected in an anterior cruciate ligament (ACL-) deficient knee
during TKR surgery, the flexion gap becomes wider than the extension
gap on average.[10,11]Although adequate gap control in knee extension and flexion is
important in both CR and PS TKR and sacrificing or sparing PCL influences
the equality of the extension and flexion gap, there is no criteria
for preserving or sacrificing PCL that consider the gap situations
of each knee.In this study, the PCL was considered only as the stabiliser
between the femur and the tibia, and component selection (CR or
PS) was determined only by intra-operative gap measurement, without
considering other functions of the PCL such as ‘roll back’. The
extension and flexion gaps were measured intra-operatively, first
with the PCL intact in all cases. In cases in which the flexion gap
was considered too small to set the components, the PCL was removed
and the gaps were measured to estimate the degree to which they
were increased by resection.
Materials and Methods
Between August 2008 and September 2010, 82 patients (65 female,
17 male) with osteoarthritis of the knee (102 knees; 81 female,
21 male), operated on by a single surgeon (RK) using a Scorpio NRG
(Stryker, Kalamazoo, Michigan) and a tension device system with
a 30 lbs distraction force, were enrolled in this study. Seven knees were
excluded because of lack of intra-operative measurement data. Mean
age at operation was 73 years (56 to 91). To assess the influence
of pre-operative flexion contracture concerning the extension-flexion
gap imbalance, materials were divided into two groups. Cases with pre-operative
flexion contracture < 20° and ≥ 20° were placed in groups A and
B, respectively, as according to Berend, Lombardi and Adams,[12] division at 20°
of flexion contracture is important.At the beginning of the surgery, the extension gap was created
with a standard 8 mm femoral distal cut and a 10 mm tibial cut.
To measure the flexion gap easily with the PCL intact before the
final femoral cut, it was necessary to create a small temporary
gap in flexion. For this purpose, a pre-cut of the femoral posterior
condyle was performed with a 4-in-1 femoral cutting guide, which was
4 mm longer in the anterior-posterior dimension than the measured
size; therefore, a pre-cutting line was 4 mm posterior compared
with a cutting line for the measured resection technique (Fig. 1).
With this technique, the flexion gap created was 4 mm smaller than
the flexion gap typically produced by the measured resection technique,
and it was easy to remove even large posterior osteophytes through
the small flexion gap made by the pre-cut. After removal of all
osteophytes, the patella was reduced, and the gaps were measured
by an offset knee balancer with a distraction force of 30 lbs. (Fig.
2). The extension gap was measured with the lower limb in a straight
position on the operating table. The flexion gap was measured with
the thigh held by the surgeon’s hand with resting pressure to prevent
lifting of the lower leg.Diagram showing the pre-cut of
the femoral posterior condyle.Intra-operative photograph showing measurement
of the flexion gap with the patella reduced.To compare both gaps, the flexion gap was corrected by the length
of the pre-cut. This corrected gap, which is a theoretical amount
and not the actual final flexion gap, is the same as a flexion gap
produced by the measured resection technique. A component type was selected
according to the extension and corrected flexion gap. If there was enough space to set the all components
on the femur and tibia in flexion with the PCL intact, the CR component
was implanted; otherwise, the PCL was resected and the PS component
selected. The degree to which PCL resection increased the two gaps was
also measured in PS cases. If necessary, soft tissue was released
for good ligament balance. An additional distal cut of the femur
was considered in cases where the extension gap was too small compared
with the flexion gap. At the final step of the surgery, the optimal
size of the femoral component for an adequate extension and flexion
space was estimated. At this time, if a 4 mm additional bone resection
was performed, it became the same surgical procedure as the measured
resection technique. A smaller or bigger bone resection than 4 mm could
be chosen for an adequate flexion gap as with the gap technique.
Specifically, it could be adjusted to up to 4 mm larger than the
measured size of the femoral component (Fig. 1).The Student’s t-test and paired t-test
were applied for statistical analysis; a p value of < 0.05 was
considered statistically significant and results presented as mean and sd.
Results
After initial bone cutting by a femoral posterior condylar pre-cut
with the PCL intact, the extension gap ranged from 9 mm to 24 mm
(16.9 mm (sd 2.9)), and the corrected flexion gap by the amount of the pre-cut ranged
from 13 mm to 30 mm (20.5 mm (sd 3.2)). There were wide
variations in both gaps and neither could be predicted pre-operatively.
The flexion gap was larger than the extension gap in almost all
of the cases and the difference was significant (p < 0.001, Fig. 3).
The difference between the two gaps ranged from -3 mm to 12 mm (3.6 mm
(sd 2.7)). It seemed too wide to make equal extension and
flexion gaps in every case (Fig. 4a).Graph showing measurement results of
the gaps after pre-cut of the femoral posterior condyle with the
posterior cruciate ligament (PCL) preserved. The mean extension
gap was 16.9 mm (sd 2.9) and the corrected flexion gap
by the amount of the pre-cut was 20.5 mm (sd 3.2). The
flexion gap was significantly larger than the extension gap (p <
0.001). The range of both gaps were too wide to know pre-operatively
in each case. Cases with 18 mm or more (minimum space to set the
component) flexion gap and larger flexion gap than extension gap
(Group 1) were implanted with a CR component, except for cases with
PCL insufficiency. A PS component was implanted with the other cases
(Group 2, 3 and 4). ○, implanted with CR component; △▲, implanted
with PS component; ▲, PS implanted due to PCL insufficiency.Figure 4a – Graph showing gap difference
between the extension gap and the corrected flexion gap. The mean
of the difference was 3.6 mm (sd 2.7) and the variation
of the difference was wide. Figure 4b – Graph showing gap difference
by group. Group A: pre-operative flexion contracture < 20°. Group
B: flexion contracture ≥ 20°. The mean differences between extension
and corrected flexion gaps were 3.4 mm (sd 2.5) in group
A and 3.9 mm (sd 3.0) in group B, (p = 0.42). Additionally,
if groups A and B are divided at flexion contracture of 15°, 25°
and 30°, the p-values are 0.39, 0.38 and 0.20 respectively.The extension and corrected flexion gaps were 17.2 mm (sd 3.0) and 20.6 mm (sd 3.2) in group A and 16.3 mm (sd 2.8)
and 20.2 mm (sd 3.3) in group B, respectively. The difference
of the mean extension gap between the two groups was only 0.9 mm,
which was not significantly different, and there was no significant difference
in flexion gap between both groups (Fig. 5).Graph showing gaps and flexion contracture.
The mean extension and corrected flexion gaps were 17.2 mm (sd 3.0)
and 20.6 mm (sd 3.2) in group A and 16.3 mm (sd 2.8)
and 20.2 mm (sd 3.3) in group B, respectively. There were
no significant differences between the two groups.The difference between the extension and flexion gap is the most
important factor to make equal-sized extension-flexion gaps; this
difference was also assessed in both groups. The mean differences
between the extension and corrected flexion gap were 3.4 mm (sd 2.5)
in group A and 3.9 mm (sd 3.0) in group B, which was not statistically
significant. The variation
of extension-flexion gap difference was very wide in both groups;
however, cases of excessive gap difference (> 8 mm) were more common
in group B (Fig. 4b).Based on the measured gaps, the CR component was selected for
use in 73 knees, and PS was used in only 29 knees. In the cases
in which the PS was selected, the gap increase following PCL resection
ranged from 0 mm to 3 mm (0.6 mm (sd 0.9)) in extension
and from 0 mm to 7 mm (2.7 mm (sd 2.0)) in flexion, and
the difference between the increases in both gaps was significant
(p < 0.001). The gap increase in extension was 0 mm or 1 mm in
almost all of the cases. Meanwhile, the variation of the flexion
gap increase was too wide to predict before PCL resection (Fig.
6).Graph showing gap increase after posterior
cruciate ligament (PCL) resection. The flexion gap increase was
significantly larger than extension, and the variation of the flexion
gap increase was wide. The gap increases following PCL resection
were 0.6 mm (sd 0.9) in extension and 2.7 mm (sd 2.0)
in flexion, and the difference between the increases of both gaps was
significant (p < 0.001).Selection of CR or PS is related to the amount of the flexion gap
and the size of the femoral component, regardless of the pre-operative
contracture or posterior osteophytes. Using a CR component, in the
case of a small flexion gap a smaller femoral component is sufficient
to create an appropriate flexion space, but it leads to undesirable
reduction of a posterior condylar offset. In large flexion gap cases
when the PS component is selected, the size of a femoral component
needs to be larger, but there might be some limitations concerning medial-lateral
over-size. Our results indicate a wide range of both gaps and a
difficulty to know the gaps in each case pre-operatively. We used
the CR component if there was enough space to set the components
in flexion with the PCL intact; otherwise, the PS component was
implanted. This concept developed a criteria in order to make the
decision as to whether or not to preserve the PCL: cases with 18 mm
(minimum space to set the component) or more flexion gap and larger
flexion gap than extension gap were suitable for a CR component;
any other cases were suitable for a PS component (Fig. 3). As a
result of using these criteria, in our cases, most knees were implanted
with the adequate femoral component size relative to the measured
size of the femur in those implanted with either CR or PS components
(Fig. 7).Graph showing the difference between
implanted and measured sizes of the femoral component. Most cases
were implanted with ± 1 size compared with the measured size of
the femur (CR, cruciate retaining; PS posterior substitute).
Discussion
TKR implant designs and materials have improved in recent decades.
However, the selection criteria for use of the CR or PS component,
one of the most fundamental factors in TKR, remains obscure. Both
components have been widely used, with good clinical results,[1-5] but there has been limited discussion
regarding their faults.[13-19] Although some
surgeons may assert that using the PS component with the gap technique
is useful for creating proper gaps during extension and flexion,[16-19] there are simple limitations. It
is not always easy to remove large posterior osteophytes with the
gap technique, which may have some influence on the gaps unless
femoral posterior condyles are resected.If the posterior
osteophytes are removed after both the extension and flexion gaps
are made, these gap amounts will change.[20,21]We found that flexion gaps were larger than extension gaps in
most of the cases, and the PCL resection made flexion gaps wider
(up to 7 mm). The gap technique can control the flexion gap by adjusting
the size of the femoral component, but there might be some limitations
concerning medial-lateral over-size. A large femoral component, relative
to the measured size, leads to an undesirable medial-lateral overhang
of the femoral component. Meanwhile, our results indicate that the
combination of the measured resection technique and the use of a
PS component, introduces the possibility of an overly large flexion
gap (Figs 3, 4a, 6). Following the measured resection of the femur,
it is difficult to change the gaps, even if the acquired gaps were
inadequate.On the other hand, the CR component also has some faults. In
cases of small flexion gaps due to a tight PCL, it is necessary
to diminish the femoral component size with a CR component. This
leads to a small femoral posterior offset, which can limit knee
flexion. Although, some surgeons may say that it is useful to partially
release the PCL in cases of a small flexion gap in CR TKR, there
is a limitation. Our results demonstrated that the widening of the flexion
gap after PCL resection is variable, and some cases showed minimal
increase of flexion gaps, even with complete PCL resection (Fig.
6).The reasons why flexion gaps are larger than extension gaps in
PCL-maintained knees are multifactorial and ambiguous. One of the
reasons is probably related to relative PCL loosening because of
ACL deficiency. Christen et al[22] and
Heesterbeek et al[23] reported
that PCL orientation with the knee at 90° was elevated by tension
between the femur and tibia in ACL-deficient knees. The elevated
PCL orientation may cause a flexion gap increase with the appropriate
distraction force between the femur and tibia.Another reason for the bigger flexion gap, compared with the
extension gap, involves pre-operative flexion contracture, which
was generally considered a decreasing factor of extension gaps.[12,24-26] Although
pre-operative flexion contracture is reported to influence extension gaps,
we found the mean difference of the extension gaps between groups
A and B was only about 1 mm and there was no significant difference
(Fig. 5). In this study, a 30 lbs distraction force was applied
to measure the gaps, however, it might not have been enough to reveal
the difference. The actual reason as to why there was no significance
is still unclear.From a viewpoint of gap difference between the flexion and extension,
a gap difference of 5 mm or more was often seen in both groups A
and B; however, extremely difficult cases with > 8 mm difference
were more common in group B and there was no case with a larger
extension gap than that of the flexion gap in group B (Fig. 4b).
The pre-operative flexion contracture could have had some influence
on the gap situation in our cases, despite the lack of significant
difference in extension gaps between the two groups. Although each
factor of PCL orientation and flexion contracture may have small
influences on the gaps, the combined effects may become significant.The importance of equal extension and flexion gaps in TKR has
been discussed; however, how this goal is achieved remains unclear.
Insall[27] described
PCL management in TKR:It must also be accepted that not all arthritic knees
are suitable for PCL-retaining designs, and there must be more objective
methods for deciding when the PCL is too tight or so loose as to
be rendered nonfunctional. When the PCL is not fulfilling its purpose
within acceptable and defined limits, a PCL release may be performed
or, alternatively, a posterior stabilized design adopted. Many newer
knee systems allow an intraoperative switch from PCL retention to
PCL substitution, and in my view this is the way of the future.[27]To create adequate extension and flexion gaps, intra-operative
gap measurement in each knee and proper component choice are important.
As he described, from a view point of gap adjustment, it seems that
some knees are not suitable for a PCL-retaining component and some are
not suitable for a PCL-substitute component and it is difficult
to decide pre-operatively which to use for an adequate gap. Our
results support his assertion by numerical data (Fig. 3). The technique
in this report is only aimed at achieving perfect gap control in
TKR. For this purpose, PCL function as a roll-back producer was
neglected, and the intra-operative gap measurement in PCL preservation was
performed to investigate the individual gap characteristics of each
knee. Component type was decided intra-operatively by the measured
gaps, without any preconceptions.Our results indicate that the selection of the PS component in
all cases would have resulted in much larger flexion gaps in many
cases. An adequate extension and flexion gap can be attained to
a limited extent, of course, by using a larger femoral component
to make the flexion gap smaller and by performing an additional
resection of the distal femur to make the extension gaps bigger,
but this technique is limited.Conversely, the use of a CR component in the case of a small
flexion gap requires a femoral component smaller than the measured
size to optimise the flexion gap, compared with the extension gap.
This, however, leads to a smaller posterior condylar offset, which
is inappropriate for good knee flexion. Considering the gap amounts
and the adequate size of the femoral component, the criteria for
PCL preservation or sacrifice can be discussed. To attain an adequately
sized femoral component in cases where the extension gap is larger than
the flexion gap, it is necessary to create an adequate flexion gap
by cutting the PCL (groups 3 and 4, Fig. 3). In the cases in which
the flexion gap is small, it also becomes necessary to cut the PCL
and create a sufficient flexion gap (groups 2 and 3, Fig. 3). This
is complicated in group 2 (Fig. 3), and an additional cut of the proximal
tibia should be considered first. If the flexion gap is still not
large enough, PCL resection should be considered. To achieve the
appropriate size for the femoral component and adequate extension
and flexion gaps, PCL resection and additional cutting of the distal femur
and proximal tibia should be considered. Selection of the PS component
leads to safer control of the extension and flexion gaps in groups
2, 3, and 4. Meanwhile, selection of the CR component only leads
to better results in group 1, but the number of cases is not small
(Fig. 3). Given the wide variations in the extension and flexion
gaps, the difference between the two gaps and the flexion gap increase
after PCL resection, it would be difficult to only use one component
(CR or PS) in every case. To attain a femoral component of an adequate
size that provides appropriate gaps, better results are achieved
by deciding which component to use (CR or PS) based on intra-operative
gap measurement.
Limitations
The chief limitation of this study was the measurement method.
In this study, 30 lbs of tension was applied as a distracting force
between the femur and tibia. However, it is still unknown how much
force is appropriate for gap measurement. Additionally, the influence
of gravity on the flexion gap measurement has not yet been discussed.
We believe it is better to measure the flexion gap when at least
some effort has been made to avoid the influence of the thigh weight.
Therefore, we measured the flexion gap with the thigh held by the
surgeon’s hand to prevent lifting of the lower leg. However, the
accuracy of this method is not verified.
Authors: Dae Kyung Bae; Sang Jun Song; Kang Il Kim; Dong Hur; Hyun Ho Lee Journal: Knee Surg Sports Traumatol Arthrosc Date: 2016-01-05 Impact factor: 4.342