| Literature DB >> 24719140 |
HeeJin Park1, Jung Ar Shin1, Hyung Jung Kim1, Chul Min Ahn1, Yoon Soo Chang1.
Abstract
PURPOSE: We investigated the value of an interferon-γ release assay (IGRA) for the diagnosis of active pulmonary tuberculosis (PTB) among sputum smear negative PTB suspects in an environment with intermediate burden of PTB and high Bacillus Calmette-Guerin (BCG) vaccination rate.Entities:
Keywords: Sputum smear negative pulmonary tuberculosis; active pulmonary tuberculosis; interferon-gamma release assay
Mesh:
Year: 2014 PMID: 24719140 PMCID: PMC3990062 DOI: 10.3349/ymj.2014.55.3.725
Source DB: PubMed Journal: Yonsei Med J ISSN: 0513-5796 Impact factor: 2.759
Fig. 1Study flow diagram. *Confirmed=positive culture results+clinical diagnosis (with negative culture results). †Confirmed=negative culture results without clinical evidence of PTB. TB, tuberculosis; n, number; QFT-IT, QuantiFERON-TB Gold In-Tube; PTB, pulmonary tuberculosis; AFB, acid fast bacilli.
Demographic and Clinical Characteristics of Patients with Suspected Active PTB among the Sputum AFB Smear Negative Patients
TB, tuberculosis; SD, standard deviation; n, number; PTB, pulmonary tuberculosis; AFB, acid fast bacilli.
*Clinical findings being compatible with TB, no clinical improvement with empirical antibiotics, and clinico-radiological improvement with treatment with anti-TB medication.
Symptoms of Sputum Smear Negative TB Suspects
TB, tuberculosis; n, numbers; PTB, pulmonary tuberculosis.
The patients, who did not have symptoms, but suspicious for PTB were screened by either annual national health screening program or by medical check-up at work place and referred to study institute.
*4 patients had no symptoms.
†1 patient had no symptoms.
‡Calculated with chi-square test.
Diagnostic Accuracy in Sputum Smear Negative TB Suspects
CI, confidence interval; QFT-IT, QuantiFERON-TB Gold In-Tube; TST, tuberculin skin test; HRCT, high-resolution chest chest high resolution computer tomography; TB, tuberculosis; CXR, chest X-ray.
*106 of 224 cases were examined with this test.
†194 of 224 cases were examined with this test.
‡p-value: <0.0001 calculated by chi-square test.
Analysis of Combination of Tests in Sputum Smear Negative PTB Suspects
CI, confidence interval; PPV, positive predictive value; NPV, negative predictive value; QFT-IT, QuantiFERON-TB Gold In-Tube; TST, tuberculin skin test; HRCT, high-resolution chest chest high resolution computer tomography; PTB, pulmonary tuberculosis.
*194 of 224 cases were examined with this test.
†106 of 224 cases were examined with this test.