Literature DB >> 24717719

Phantom experiment and clinical utility of quantitative shear wave elastography for differentiating thyroid nodules.

Takahiro Fukuhara1, Eriko Matsuda, Kazunori Fujiwara, Chika Tanimura, Shoichiro Izawa, Hideyuki Kataoka, Hiroya Kitano.   

Abstract

Shear wave elastography (SWE) using acoustic radiation force impulse (ARFI) is a novel ultrasonography technique. The aim of this study was to investigate the clinical usefulness of quantitative SWE for differentiating thyroid nodules. For phantom study, we measured the shear wave velocities (SWVs) of the four spheres of 2- and 1-cm diameters with varying hardness. For clinical study, the SWVs of normal thyroid glands and thyroid nodules, that were classified as benign or malignant according to either cytological or pathological findings, were measured. The SWVs of each thyroid patient were compared with that of a normal thyroid and each other. In phantom study, the SWVs for the 2-cm spheres correlated with the hardness of the targets, whereas the values for the 1-cm spheres did not. In clinical study, 112 nodules identified in 167 patients and 94 normal thyroid glands were analyzed according to the criteria for the study. The nodules included 84 benign nodules, and 28 papillary carcinoma. The mean SWVs of each group were 1.64 ± 0.47 m/s for normal thyroid, 1.88 ± 0.62 m/s for benign nodules and 2.67 ± 0.76 m/s for papillary carcinoma. The SWVs of papillary carcinoma were significantly higher than those of benign nodules (P < 0.001). The area under the ROC curve was 0.809 with a cut-off value of 2.01 m/s. The sensitivity and specificity were 85.7% and 62.0% respectively. Results showed that SWE provides new information on tumor characteristics, such as hardness and larger nodules tended to provide stable measurements.

Entities:  

Mesh:

Year:  2014        PMID: 24717719     DOI: 10.1507/endocrj.ej14-0061

Source DB:  PubMed          Journal:  Endocr J        ISSN: 0918-8959            Impact factor:   2.349


  8 in total

1.  VsN, a Reliability-index of Shear-wave Measurement in Sonoelastography, Is Useful for the Diagnosis of Thyroid Tumor Malignancy.

Authors:  Tomoo Jikuzono; Osamu Ishibashi; Shoko Kure; Chiaki Itoh; Tetsu Yamada; Iwao Sugitani
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

2.  Virtual touch tissue imaging and quantification (VTIQ) in the evaluation of thyroid nodules: the associated factors leading to misdiagnosis.

Authors:  Cheng-Yu Sun; Kai-Rong Lei; Bo-Ji Liu; Xiao-Wan Bo; Xiao-Long Li; Ya-Ping He; Dan Wang; Wei-Wei Ren; Chong-Ke Zhao; Hui-Xiong Xu
Journal:  Sci Rep       Date:  2017-02-03       Impact factor: 4.379

3.  Value of Contrast-Enhanced Ultrasound and Acoustic Radiation Force Impulse Imaging for the Differential Diagnosis of Benign and Malignant Thyroid Nodules.

Authors:  Yan He; Xiao Yan Wang; Qiao Hu; Xue Xue Chen; Bing Ling; Hai Ming Wei
Journal:  Front Pharmacol       Date:  2018-11-27       Impact factor: 5.810

4.  Elastography for the evaluation of thyroid nodules in pediatric patients.

Authors:  Gustavo Bittar Cunha; Luciana Cristante Izar Marino; André Yamaya; Cristiane Kochi; Osmar Monte; Carlos Alberto Longui; Adriano Namo Cury; Eduardo de Faria Castro Fleury
Journal:  Radiol Bras       Date:  2019 May-Jun

5.  Utility of Shear Wave Elastography for Diagnosing Chronic Autoimmune Thyroiditis.

Authors:  Takahiro Fukuhara; Eriko Matsuda; Shoichiro Izawa; Kazunori Fujiwara; Hiroya Kitano
Journal:  J Thyroid Res       Date:  2015-07-16

6.  Impact of Fibrotic Tissue on Shear Wave Velocity in Thyroid: An Ex Vivo Study with Fresh Thyroid Specimens.

Authors:  Takahiro Fukuhara; Eriko Matsuda; Yukari Endo; Ryohei Donishi; Shoichiro Izawa; Kazunori Fujiwara; Hiroya Kitano; Hiromi Takeuchi
Journal:  Biomed Res Int       Date:  2015-12-31       Impact factor: 3.411

7.  Comparison of Diagnostic Accuracy of Real-Time Elastography and Shear Wave Elastography in Differentiation Malignant From Benign Thyroid Nodules.

Authors:  Wuguo Tian; Shuai Hao; Bo Gao; Yan Jiang; Shu Zhang; Lingji Guo; Donglin Luo
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

8.  Clinical efficacy of novel elastography using acoustic radiation force impulse (ARFI) for diagnosis of malignant thyroid nodules.

Authors:  Takahiro Fukuhara; Eriko Matsuda; Ryohei Donishi; Satoshi Koyama; Naritomo Miyake; Kazunori Fujiwara; Hiromi Takeuchi
Journal:  Laryngoscope Investig Otolaryngol       Date:  2018-08-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.