Literature DB >> 24710825

Phantom for assessment of fat suppression in large field-of-view diffusion-weighted magnetic resonance imaging.

J M Winfield1, N H M Douglas, N M deSouza, D J Collins.   

Abstract

We present the development and application of a phantom for assessment and optimization of fat suppression over a large field-of-view in diffusion-weighted magnetic resonance imaging at 1.5 T and 3 T. A Perspex cylinder (inner diameter 185 mm, height 300 mm) which contains a second cylinder (inner diameter 140 mm) was constructed. The inner cylinder was filled with water doped with copper sulphate and sodium chloride and the annulus was filled with corn oil, which closely matches the spectrum and longitudinal relaxation times of subcutaneous abdominal fat. Placement of the phantom on the couch at 45° to the z-axis presented an elliptical cross-section, which was of a similar size and shape to axial abdominal images. The use of a phantom for optimization of fat suppression allowed quantitative comparison between studies without the differences introduced by variability between human subjects. We have demonstrated that the phantom is suitable for selection of inversion delay times, spectral adiabatic inversion recovery delays and assessment of combinatorial methods of fat suppression. The phantom is valuable in protocol development and the assessment of new techniques, particularly in multi-centre trials.

Entities:  

Mesh:

Year:  2014        PMID: 24710825     DOI: 10.1088/0031-9155/59/9/2235

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Comparative study of fat-suppression techniques for hip arthroplasty MR imaging.

Authors:  Sébastien Molière; Jean-Philippe Dillenseger; Matthieu Ehlinger; Stéphane Kremer; Guillaume Bierry
Journal:  Skeletal Radiol       Date:  2017-05-24       Impact factor: 2.199

2.  The effect of noise and lipid signals on determination of Gaussian and non-Gaussian diffusion parameters in skeletal muscle.

Authors:  Donnie Cameron; Mustapha Bouhrara; David A Reiter; Kenneth W Fishbein; Seongjin Choi; Christopher M Bergeron; Luigi Ferrucci; Richard G Spencer
Journal:  NMR Biomed       Date:  2017-04-06       Impact factor: 4.044

Review 3.  Implementing diffusion-weighted MRI for body imaging in prospective multicentre trials: current considerations and future perspectives.

Authors:  N M deSouza; J M Winfield; J C Waterton; A Weller; M-V Papoutsaki; S J Doran; D J Collins; L Fournier; D Sullivan; T Chenevert; A Jackson; M Boss; S Trattnig; Y Liu
Journal:  Eur Radiol       Date:  2017-09-27       Impact factor: 5.315

4.  Implementation of Whole-Body MRI (MY-RADS) within the OPTIMUM/MUKnine multi-centre clinical trial for patients with myeloma.

Authors:  Mihaela Rata; Matthew Blackledge; Erica Scurr; Jessica Winfield; Dow-Mu Koh; Alina Dragan; Antonio Candito; Alexander King; Winston Rennie; Suchi Gaba; Priya Suresh; Paul Malcolm; Amy Davis; Anjumara Nilak; Aarti Shah; Sanjay Gandhi; Mauro Albrizio; Arnold Drury; Sadie Roberts; Matthew Jenner; Sarah Brown; Martin Kaiser; Christina Messiou
Journal:  Insights Imaging       Date:  2022-07-28

5.  Inter- and Intra-Observer Repeatability of Quantitative Whole-Body, Diffusion-Weighted Imaging (WBDWI) in Metastatic Bone Disease.

Authors:  Matthew D Blackledge; Nina Tunariu; Matthew R Orton; Anwar R Padhani; David J Collins; Martin O Leach; Dow-Mu Koh
Journal:  PLoS One       Date:  2016-04-28       Impact factor: 3.240

Review 6.  DCE-MRI, DW-MRI, and MRS in Cancer: Challenges and Advantages of Implementing Qualitative and Quantitative Multi-parametric Imaging in the Clinic.

Authors:  Jessica M Winfield; Geoffrey S Payne; Alex Weller; Nandita M deSouza
Journal:  Top Magn Reson Imaging       Date:  2016-10

Review 7.  Diffusion-Weighted Magnetic Resonance Imaging in Ovarian Cancer: Exploiting Strengths and Understanding Limitations.

Authors:  Tanja Gagliardi; Margaret Adejolu; Nandita M deSouza
Journal:  J Clin Med       Date:  2022-03-10       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.