| Literature DB >> 24708593 |
Mauro Giorcelli1, Patrizia Savi, Mario Miscuglio, Muna Hajj Yahya, Alberto Tagliaferro.
Abstract
A wide-band microwave characterization of nanocomposites based on commercial multiwalled carbon nanotubes (MWCNTs) and epoxy resin is presented. The sample preparation method is discussed in detail. Field emission scanning electron microscopy is used for morphological sample analysis of nanocomposites and MWCNTs. The complex permittivity is measured in a wide frequency band (3 to 18 GHz) using a commercial dielectric probe (Agilent 85070D) and a network analyzer (E8361A). A statistical analysis based on one-way analysis of variance (ANOVA) technique is performed. The aim of this statistical analysis is to investigate the influence of concentration of nanoparticles inside the polymer matrix on the complex permittivity. This can be significantly different in nanocomposites even if the samples have similar electrical properties.Entities:
Year: 2014 PMID: 24708593 PMCID: PMC3986468 DOI: 10.1186/1556-276X-9-168
Source DB: PubMed Journal: Nanoscale Res Lett ISSN: 1556-276X Impact factor: 4.703
Figure 1Image of NC and sketch of the setup. Left panel: image of NC (pristine epoxy resin reinforcement) (black) and polymer (pristine epoxy resin) (transparent). Right panel: sketch of the measurement setup.
Figure 2FESEM images of MWCNTs and crio-fractured area of NC. FESEM images of used MWCNTs (A, B) and crio-fractured area of the NC at 1 wt.% (C) and 3 wt.% (D) of MWCNTs.
Figure 3Relative permittivity of studied NC. Left, real part. Right, imaginary part.
Figure 4Statistical analysis. **p ≤ 0.01; ***p ≤ 0.001. Error bars represent the standard deviation of measurements performed.
Multiple comparison summary - relative permittivity - real part
| 1 wt.% vs. 3 wt.% | -2.186 | -2.865 to -1.507 | 0.0031 | Yes | ** |
| 1 wt.% vs. Epilox | 0.5255 | -0.09689 to 1.148 | 0.1233 | No | ns |
| 3 wt.% vs. Epilox | 2.712 | 1.870 to 3.553 | 0.0027 | Yes | ** |
**p ≤ 0.01, ns, not significant; diff, difference.
Multiple comparison summary - relative permittivity - imaginary part
| 1 wt.% vs. 3 wt.% | -0.5777 | -0.6655 to 0.4899 | 0.0002 | Yes | *** |
| 1 wt.% vs. Epilox | 0.1014 | -0.0446 to 0.2474 | 0.1265 | No | ns |
| 3 wt.% vs. Epilox | 0.6792 | 0.5381 to 0.8202 | 0.0006 | Yes | *** |
***p ≤ 0.001; ns, not significant; diff, difference.