Literature DB >> 24703790

Contribution of patient-specific cutting guides to lower limb alignment for total knee arthroplasty.

H Moubarak1, J Brilhault2.   

Abstract

UNLABELLED: Patient-specific cutting guides (PSCG) are an extension of preoperative planning for total knee arthroplasty (TKA). We wanted to evaluate their contribution to postoperative lower limb alignment. This study involved primary TKA cases being performed with PSCG between 10/05/2010 and 05/03/2013 and then followed prospectively. The analysis involved the PSCG usage and postoperative measurement of the patient's HKA, medial distal femoral joint angle (MDFA) and medial proximal tibia joint angle (MPTA). Of the 104 eligible cases, 68 were included; 11 of these cases were not performed completely with the PSCG as initially planned. Thus we compared these 11 cases with the 57 where PSCG were used. The preoperative HKA in the included cases was 175.8° ± 7.8; the postoperative angles on average were 179.2° ± 2.9 for the HKA, 89.9° ± 1.6 for the MDFA and 89.0° ± 2.3 for the MPTA. The average postoperative deviation from the target values was 2.22° ± 2.14 for the HKA angle, 1.07° ± 1.15 for the MDFA and 1.66° ± 1.90 for the MPTA. There were no significant differences between the two groups in any of the measurements. The lower limb alignment goal was achieved in 50 cases (73%), with 41 of these achieved with PSCG (82%). Of the 18 cases where the target was not achieved, PSCG were used 16 times (88%). In this study cohort, lower limb alignment was not significantly closer to an HKA of 180° or achieved more often with the use of PSCG versus standard instrumentation. Since the results of the two groups can be superimposed, we found no evidence that use of PSCG improves postoperative lower limb alignment. LEVEL OF EVIDENCE IV. STUDY TYPE: Cohort.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Accuracy; Patient-specific instrumentation; Total knee arthroplasty

Mesh:

Year:  2014        PMID: 24703790     DOI: 10.1016/j.otsr.2014.03.006

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  4 in total

Review 1.  Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis.

Authors:  Etienne Cavaignac; Regis Pailhé; Gregoire Laumond; Jérôme Murgier; Nicolas Reina; Jean Michel Laffosse; Emilie Bérard; Philippe Chiron
Journal:  Int Orthop       Date:  2014-10-10       Impact factor: 3.075

2.  CT-based TruMatch® Personal Solutions for knee replacement Surgery … Does it really match?

Authors:  Amila N Silva; You Wei Adriel Tay; Sharon Tan Si Heng; Siang Shen Leon Foo; Hee Nee Pang; Darren Tay Keng Jin; Ngai Nung Lo; Seng Jin Yeo
Journal:  J Orthop       Date:  2019-11-27

Review 3.  3D-printing techniques in a medical setting: a systematic literature review.

Authors:  Philip Tack; Jan Victor; Paul Gemmel; Lieven Annemans
Journal:  Biomed Eng Online       Date:  2016-10-21       Impact factor: 2.819

4.  Postoperative mechanical alignment analysis of total knee replacement patients operated with 3D printed patient specific instruments: A Prospective Cohort Study.

Authors:  Halil Can Gemalmaz; Kerim Sarıyılmaz; Okan Ozkunt; Mustafa Sungur; Ibrahim Kaya; Fatih Dikici
Journal:  Acta Orthop Traumatol Turc       Date:  2019-03-08       Impact factor: 1.511

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.