Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

Cheolpyo Hong1, Dong-Hoon Lee2, Bong Soo Han3.   

Abstract

Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinearity hinders the practical applications of open-type MRI. We demonstrated the use of geometric distortion correction for increasing FOV in open MRI. Geometric distortion was modeled and corrected as a global polynomial function. The appropriate polynomial order was identified as the minimum difference between the coordinates of control points in the distorted MR image space and those predicted by polynomial modeling. The sixth order polynomial function was found to give the optimal value for geometric distortion correction. The area of maximum distortion was<1 pixel with an FOV of 285mm. The correction performance error was increased at most 1.2% and 2.9% for FOVs of 340mm and~400mm compared with the FOV of 285mm. In particular, unresolved distortion was generated by local deformation near the gradient coil center.
Copyright © 2014 Elsevier Inc. All rights reserved.

Keywords:  Distortion correction; Large field-of-view; Open MRI

Mesh:

Year:  2014        PMID: 24698340     DOI: 10.1016/j.mri.2014.02.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM.

Authors:  Ryan G Price; Mo Kadbi; Joshua Kim; James Balter; Indrin J Chetty; Carri K Glide-Hurst
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

2.  Prospective analysis of in vivo landmark point-based MRI geometric distortion in head and neck cancer patients scanned in immobilized radiation treatment position: Results of a prospective quality assurance protocol.

Authors: 
Journal:  Clin Transl Radiat Oncol       Date:  2017-10-10

3.  Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study.

Authors:  Anh H Nguyen; Adria Perez-Rovira; Piotr A Wielopolski; Juan A Hernandez Tamames; Liesbeth Duijts; Marleen de Bruijne; Andrea Aliverti; Francesca Pennati; Tetyana Ivanovska; Harm A W M Tiddens; Pierluigi Ciet
Journal:  Eur Radiol       Date:  2018-12-05       Impact factor: 5.315

4.  Characterizing geometrical accuracy in clinically optimised 7T and 3T magnetic resonance images for high-precision radiation treatment of brain tumours.

Authors:  Jurgen Peerlings; Inge Compter; Fiere Janssen; Christopher J Wiggins; Alida A Postma; Felix M Mottaghy; Philippe Lambin; Aswin L Hoffmann
Journal:  Phys Imaging Radiat Oncol       Date:  2019-01-03

5.  Technical Note: Extended field-of-view (FOV) MRI distortion determination through multi-positional phantom imaging.

Authors:  Emil Schüler; Richard Mallozzi; Joshua Levy; Dimitre Hristov
Journal:  J Appl Clin Med Phys       Date:  2020-10-19       Impact factor: 2.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.