Literature DB >> 24697976

Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments.

Ismail Davut Capar1, Huseyin Ertas, Hakan Arslan.   

Abstract

New files (ProTaper Next/HyFlex/OneShape) are made from novel nickel-titanium (NiTi) alloys/treatments. The purpose of this study was to compare the cyclic fatigue resistance of these new instruments with that of Revo-S instruments. Four groups of 20 NiTi endodontic instruments were tested in steel canals with a 3 mm radius and a 60° angle of curvature. The cyclic fatigue of the following NiTi instruments with a tip size 25 and 0.06 taper that were manufactured with different alloys was tested: ProTaper Next X2 (M-Wire), OneShape (conventional NiTi), Revo-S Shaping Universal (conventional NiTi) and HyFlex 25/0.6 (controlled memory NiTi wire). A one-way anova and post-hoc Tukey's test (α = 0.05) revealed that the HyFlex files had the highest fatigue resistance and the Revo-S had the least fatigue resistance among the groups (P < 0.001).
© 2014 Australian Society of Endodontology.

Entities:  

Keywords:  ProTaper Next; cyclic fatigue; heat treatment; nickel-titanium files; rotary

Mesh:

Substances:

Year:  2014        PMID: 24697976     DOI: 10.1111/aej.12067

Source DB:  PubMed          Journal:  Aust Endod J        ISSN: 1329-1947            Impact factor:   1.659


  20 in total

1.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

2.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

3.  In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

Authors:  Gabriele Miccoli; Gianfranco Gaimari; Marco Seracchiani; Antonio Morese; Tatyana Khrenova; Dario Di Nardo
Journal:  Ann Stomatol (Roma)       Date:  2017-11-08

4.  Topographic Analysis of HyFlex(®) Controlled Memory Nickel-Titanium Files.

Authors:  Dina Al-Sudani
Journal:  J Int Oral Health       Date:  2014 Nov-Dec

5.  Assessment of the role of cross section on fatigue resistance of rotary files when used in reciprocation.

Authors:  Vadhana Sekar; Ranjith Kumar; Suresh Nandini; Suma Ballal; Natanasabapathy Velmurugan
Journal:  Eur J Dent       Date:  2016 Oct-Dec

6.  In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals.

Authors:  Koray Yılmaz; Gülşah Uslu; Taha Özyürek
Journal:  Restor Dent Endod       Date:  2017-10-30

Review 7.  Rotary science and its impact on instrument separation: A focused review.

Authors:  Sandhya Anand Khasnis; Prem Prakash Kar; Apoorva Kamal; Jayaprakash D Patil
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

8.  Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments.

Authors:  Huseyin Ertas; Ismail Davut Capar; Hakan Arslan; Ender Akan
Journal:  Biomed Eng Online       Date:  2014-05-31       Impact factor: 2.819

9.  Cyclic Fatigue Resistance and Force Generated by OneShape Instruments during Curved Canal Preparation.

Authors:  Zhuyu Wang; Wen Zhang; Xiaolei Zhang
Journal:  PLoS One       Date:  2016-08-11       Impact factor: 3.240

10.  Cyclic Fatigue Life of Two Single File Engine-Driven Systems in Simulated Curved Canals.

Authors:  Mohammad Reza Nabavizadeh; Mahdi Sedigh-Shams; Sara Abdolrasoulnia
Journal:  Iran Endod J       Date:  2018
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.