Literature DB >> 24691685

Harmonization of measurement results of the alcohol biomarker carbohydrate-deficient transferrin by use of the toolbox of technical procedures of the International Consortium for Harmonization of Clinical Laboratory Results.

Cas Weykamp1, Jos Wielders2, Anders Helander3, Raymond F Anton4, Vincenza Bianchi5, Jan-Olof Jeppsson6, Carla Siebelder7, John B Whitfield8, François Schellenberg9.   

Abstract

BACKGROUND: The need for equivalent results of routine measurement procedures for the alcohol biomarker carbohydrate-deficient transferrin (CDT) has been recognized by the IFCC. This article describes a project to harmonize CDT as conducted by an IFCC working group initiated for this purpose.
METHODS: We used procedures for achieving harmonization as developed by the Consortium for Harmonization of Clinical Laboratory Results to assess the suitability of a candidate reference measurement procedure (cRMP), candidate reference materials (cRMs), and the success of efforts to achieve harmonization.
RESULTS: CDT measurement procedures in routine use showed good reproducibility (CV 1.1%-2.8%) and linearity (r > 0.990) with variable slopes (0.766-1.065) and intercepts (-0.34 to 0.92) compared to the cRMP. Heterogeneity after simulated harmonization was 4.7%. cRMs of frozen human native sera demonstrated commutability and 3-year stability for routine measurement procedures. The cRMP provided reproducible value assignment to cRMs with an expanded uncertainty (k = 2) of 0.03% at the 1.2% CDT level and 0.06% at the 4.4% CDT level. Harmonization efforts reduced the intermeasurement CV from 8.8% to 3.4%, allowed 99% recovery of the values assigned with the cRMP, and demonstrated 99% of results within the desirable allowable total error. Harmonization was less successful in samples with low CDT and high trisialotransferrin concentrations.
CONCLUSIONS: Harmonization of CDT is possible with frozen human native sera as cRMs with values assigned by use of the cRMP. We propose the cRMP as a candidate international conventional reference measurement procedure and cRMs as candidate international calibrators.
© 2014 The American Association for Clinical Chemistry.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24691685     DOI: 10.1373/clinchem.2014.221531

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  2 in total

1.  Carbohydrate-Deficient Transferrin Determination in a Clinical Setting: Consistency Between Capillary Electrophoresis Assays and Utility of HPLC as a Confirmatory Test.

Authors:  Agnese Veronesi; Cristina Rota; Tommaso Trenti; Elisabetta Cariani
Journal:  J Clin Lab Anal       Date:  2015-10-26       Impact factor: 2.352

2.  Harmonization of Clinical Laboratory Information - Current and Future Strategies.

Authors:  Mario Plebani
Journal:  EJIFCC       Date:  2016-02-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.