Literature DB >> 24683651

Self-designed femoral neck guide pin locator for femoral neck fractures.

Shengli Xia, Ziping Wang, Minghui Wang, Zuming Wu, Xiuhui Wang.   

Abstract

Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle positioning and with general guide pin locator positioning provided by equipment manufacturers. The screw reset rate, screw parallelism, triangle area formed by the link line of the entry point of 3 guide pins, and maximum vertical load bearing of the femoral neck after internal fixation were recorded. As expected, the triangle area was largest in the self-designed positioning group, followed by the general positioning group and the freehand positioning group. The difference among the 3 groups was statistically significant (P<.05). Anteroposterior and lateral radiographs showed that the screws were more parallel in the self-designed positioning group and general positioning group compared with the freehand positioning group (P<.05). The screw reset rate in the self-designed positioning group was significantly lower than that in the general positioning group and the freehand positioning group (P<.05). Maximum bearing load among the 3 groups was equivalent, showing no statistically significant difference (P>.05). The authors’ self-designed guide pin positioning system has the potential to accurately insert cannulated screws in femoral neck fractures and may reduce bone loss and unnecessary radiation.

Entities:  

Mesh:

Year:  2014        PMID: 24683651     DOI: 10.3928/01477447-20131219-11

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  2 in total

1.  A localization method for guide pin insertion points in the treatment of femoral neck fracture with closed reduction and percutaneous cannulated screw fixation.

Authors:  Lingsen Yang; Yang Li; Lu Qi; Wenpeng Xie; Yanhua Chen
Journal:  Ann Transl Med       Date:  2022-05

2.  Introduction of a guide based on a femoral neck section for fixation with multiple screws: a cadaveric study.

Authors:  Qiuliang Zhu; Bin Xu; Jinzhu Lv; Maohua Yan
Journal:  BMC Musculoskelet Disord       Date:  2018-04-04       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.