Literature DB >> 24677562

Reduction of motion artifacts in carotid MRI using free-induction decay navigators.

Petter Dyverfeldt1, Vibhas S Deshpande, Tobias Kober, Gunnar Krueger, David Saloner.   

Abstract

PURPOSE: To develop a framework for prospective free-induction decay (FID)-based navigator gating for suppression of motion artifacts in carotid magnetic resonance imaging (MRI) and to assess its capability in vivo.
MATERIALS AND METHODS: An FID-navigator, comprising a spatially selective low flip-angle sinc-pulse followed by an analog-to-digital converter (ADC) readout, was added to a conventional turbo spin-echo (TSE) sequence. Real-time navigator processing delivered accept/reject-and-reacquire decisions to the sequence. In this Institutional Review Board (IRB)-approved study, seven volunteers were scanned with a 2D T2-weighted TSE sequence. A reference scan with volunteers instructed to minimize motion as well as nongated and gated scans with volunteers instructed to perform different motion tasks were performed in each subject. Multiple image quality measures were employed to quantify the effect of gating.
RESULTS: There was no significant difference in lumen-to-wall sharpness (2.3 ± 0.3 vs. 2.3 ± 0.4), contrast-to-noise ratio (CNR) (9.0 ± 2.0 vs. 8.5 ± 2.0), or image quality score (3.1 ± 0.9 vs. 2.6 ± 1.2) between the reference and gated images. For images acquired during motion, all image quality measures were higher (P < 0.05) in the gated compared to nongated images (sharpness: 2.3 ± 0.4 vs. 1.8 ± 0.5, CNR: 8.5 ± 2.0 vs. 7.2 ± 2.0, score: 2.6 ± 1.2 vs. 1.8 ± 1.0).
CONCLUSION: Artifacts caused by the employed motion tasks deteriorated image quality in the nongated scans. These artifacts were alleviated with the proposed FID-navigator.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  FID navigator; atherosclerosis; carotid MRI; carotid artery disease; motion compensation; motion suppression

Mesh:

Year:  2013        PMID: 24677562      PMCID: PMC4019716          DOI: 10.1002/jmri.24389

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  31 in total

1.  Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography.

Authors:  D Li; J C Carr; S M Shea; J Zheng; V S Deshpande; P A Wielopolski; J P Finn
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Improved efficiency in double-inversion fast spin-echo imaging.

Authors:  Dennis L Parker; K Craig Goodrich; Marilyn Masiker; Jay S Tsuruda; Gregory L Katzman
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  Multislice double inversion pulse sequence for efficient black-blood MRI.

Authors:  Hee Kwon Song; Alexander C Wright; Ronald L Wolf; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

4.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

5.  Multislice double inversion-recovery black-blood imaging with simultaneous slice reinversion.

Authors:  Vasily L Yarnykh; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2003-04       Impact factor: 4.813

6.  Parallel and nonparallel simultaneous multislice black-blood double inversion recovery techniques for vessel wall imaging.

Authors:  Vitalii V Itskovich; Venkatesh Mani; Gabor Mizsei; Juan Gilberto S Aguinaldo; Daniel D Samber; Frank Macaluso; Paul Wisdom; Zahi A Fayad
Journal:  J Magn Reson Imaging       Date:  2004-04       Impact factor: 4.813

7.  Surface coil phased arrays for high-resolution imaging of the carotid arteries.

Authors:  C E Hayes; C M Mathis; C Yuan
Journal:  J Magn Reson Imaging       Date:  1996 Jan-Feb       Impact factor: 4.813

8.  Early clinical differentiation of cerebral infarction from severe atherosclerotic stenosis and cardioembolism.

Authors:  S G Timsit; R L Sacco; J P Mohr; M A Foulkes; T K Tatemichi; P A Wolf; T R Price; D B Hier
Journal:  Stroke       Date:  1992-04       Impact factor: 7.914

Review 9.  From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: Part I.

Authors:  Morteza Naghavi; Peter Libby; Erling Falk; S Ward Casscells; Silvio Litovsky; John Rumberger; Juan Jose Badimon; Christodoulos Stefanadis; Pedro Moreno; Gerard Pasterkamp; Zahi Fayad; Peter H Stone; Sergio Waxman; Paolo Raggi; Mohammad Madjid; Alireza Zarrabi; Allen Burke; Chun Yuan; Peter J Fitzgerald; David S Siscovick; Chris L de Korte; Masanori Aikawa; K E Juhani Airaksinen; Gerd Assmann; Christoph R Becker; James H Chesebro; Andrew Farb; Zorina S Galis; Chris Jackson; Ik-Kyung Jang; Wolfgang Koenig; Robert A Lodder; Keith March; Jasenka Demirovic; Mohamad Navab; Silvia G Priori; Mark D Rekhter; Raymond Bahr; Scott M Grundy; Roxana Mehran; Antonio Colombo; Eric Boerwinkle; Christie Ballantyne; William Insull; Robert S Schwartz; Robert Vogel; Patrick W Serruys; Goran K Hansson; David P Faxon; Sanjay Kaul; Helmut Drexler; Philip Greenland; James E Muller; Renu Virmani; Paul M Ridker; Douglas P Zipes; Prediman K Shah; James T Willerson
Journal:  Circulation       Date:  2003-10-07       Impact factor: 29.690

10.  Quantitative assessment of carotid plaque composition using multicontrast MRI and registered histology.

Authors:  Sharon E Clarke; Robert R Hammond; J Ross Mitchell; Brian K Rutt
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

View more
  7 in total

1.  Head motion measurement and correction using FID navigators.

Authors:  Tess E Wallace; Onur Afacan; Maryna Waszak; Tobias Kober; Simon K Warfield
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

Review 2.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

3.  Cardiorespiratory motion-tracking via self-refocused rosette navigators.

Authors:  David Rigie; Thomas Vahle; Tiejun Zhao; Björn Czekella; Lynn J Frohwein; Klaus Schäfers; Fernando E Boada
Journal:  Magn Reson Med       Date:  2019-01-07       Impact factor: 4.668

Review 4.  Vessel Wall MR Imaging in the Pediatric Head and Neck.

Authors:  Mahmud Mossa-Basha; Chengcheng Zhu; Lei Wu
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-11       Impact factor: 1.376

5.  Motion-compensated 3D turbo spin-echo for more robust MR intracranial vessel wall imaging.

Authors:  Zhehao Hu; Andre van der Kouwe; Fei Han; Jiayu Xiao; Junzhou Chen; Hui Han; Xiaoming Bi; Debiao Li; Zhaoyang Fan
Journal:  Magn Reson Med       Date:  2021-03-25       Impact factor: 3.737

6.  Navigator-based reacquisition and estimation of motion-corrupted data: Application to multi-echo spin echo for carotid wall MRI.

Authors:  Robert Frost; Luca Biasiolli; Linqing Li; Katherine Hurst; Mohammad Alkhalil; Robin P Choudhury; Matthew D Robson; Aaron T Hess; Peter Jezzard
Journal:  Magn Reson Med       Date:  2019-11-07       Impact factor: 4.668

7.  Free induction decay navigator motion metrics for prediction of diagnostic image quality in pediatric MRI.

Authors:  Tess E Wallace; Onur Afacan; Camilo Jaimes; Joanne Rispoli; Kristina Pelkola; Monet Dugan; Tobias Kober; Simon K Warfield
Journal:  Magn Reson Med       Date:  2021-01-06       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.