Literature DB >> 24674810

Adhesion of dental porcelain to cast, milled, and laser-sintered cobalt-chromium alloys: shear bond strength and sensitivity to thermocycling.

Josep Serra-Prat1, Jordi Cano-Batalla2, Josep Cabratosa-Termes3, Oscar Figueras-Àlvarez4.   

Abstract

STATEMENT OF PROBLEM: New technologies have led to the introduction of new materials, so an evaluation of the adhesion of ceramics to these materials is needed.
PURPOSE: The purpose of this study was to compare the shear bond strength of dental porcelain to cast, milled, and laser-sintered cobalt-chromium alloys, and to investigate the adhesive bond and failure type after thermocycling, 90 metal cylinders (10 mm diameter and 10 mm height) were prepared from cast (30 specimens), milled (30 specimens), and laser-sintered (30 specimens) alloys.
MATERIAL AND METHODS: Ceramic cylinders (2.5 mm diameter and 4 mm length) were fused to the alloy cylinders. For each group, 15 specimens were thermocycled 5500 times at temperatures between 4°C and 60°C before testing. After testing, the specimen surfaces were visually examined to determine the failure mode. Differences in adhesion values according to manufacturing method, testing condition (thermocycling or no thermocycling), and interaction between the factors were evaluated with a 2-way ANOVA. The χ(2) test (95% confidence level) was performed to determine whether the failure mode was associated with the testing condition.
RESULTS: Adhesion strengths for the nonthermocycled specimens were 42.79 ±14.14 MPa (cast), 37.56 ±9.18 MPa (milled), and 29.09 ±6.95 MPa (laser-sintered), and, for the thermocycled specimens, 16.52 ±8.96 MPa (cast), 22.21 ±13.25 MPa (milled), and 24.28 ±10.13 MPa (laser-sintered). Two-way ANOVA results indicated no statistically significant differences in adhesion among the manufacturing methods (P=.257), but statistically significant differences were observed according to both testing conditions (P<.001) and interaction between the factors (P=.015). The χ(2) test indicated that the failure mode was not associated with the testing condition (thermocycled, P=.280; nonthermocycled, P=.240).
CONCLUSIONS: The porcelain adhesion values for all the materials were adequate for clinical applications. No significant adhesion differences were observed between cast, milled, and laser-sintered specimens, or among thermocycled and nonthermocycled laser-sintered specimens. However, significant adhesion differences were observed among the thermocycled and nonthermocycled cast and the milled specimens.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24674810     DOI: 10.1016/j.prosdent.2014.01.004

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  [Effect of different sandblasting conditions on the metal-ceramic bonding strength of Co-Cr alloy fabricated by selective laser melting technology].

Authors:  Qian-Qian Yu; Jing Guo; Hong-Shui Zhu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-10-01

2.  Comparative evaluation of shear bond strength between titanium-ceramic and cobalt-chromium-ceramic: An in vitro study.

Authors:  Kamal Ramjee Vaska; Chandrasekhar Nakka; K Mahendranath Reddy; Siddesh Kumar Chintalapudi
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

3.  Evaluation of the Bond Strengths between Dental Porcelain and Cobalt-Chromium Metal Frameworks Manufactured with Different Techniques after the Thermal Aging Process.

Authors:  Elif Ece Yoldan; Nurullah Türker; Ulviye Ş Büyükkaplan; Mehmet M Özarslan; Recep Karalı; Ahmet T Deniz
Journal:  Scanning       Date:  2020-04-29       Impact factor: 1.932

4.  The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy.

Authors:  Mitra Farzin; Rashin Giti; Amin Asalforush-Rezaiye
Journal:  Materials (Basel)       Date:  2018-03-22       Impact factor: 3.623

5.  Mechanical Properties of Selective Laser Sintering Pure Titanium and Ti-6Al-4V, and Its Anisotropy.

Authors:  Yuu Harada; Yoshiki Ishida; Daisuke Miura; Satoru Watanabe; Harumi Aoki; Taira Miyasaka; Akikazu Shinya
Journal:  Materials (Basel)       Date:  2020-11-11       Impact factor: 3.623

6.  Effect of Cathodic Arc Plasma Deposition on Shear Bond Strength between Palladium Cobalt Chromium Coated with Titanium Nitride and Titanium Aluminium Nitride with Ceramic.

Authors:  Vaishnavi Prabhakar; Ahila Singaravel Chidambaranathan; Muthukumar Balasubramanium
Journal:  Contemp Clin Dent       Date:  2021-03-20

7.  Cobalt-chromium alloys in fixed prosthodontics in Sweden.

Authors:  Maria Kassapidou; Victoria Franke Stenport; Lars Hjalmarsson; Carina B Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-08-11

8.  Comparative Analysis of Mechanical Properties and Metal-Ceramic Bond Strength of Co-Cr Dental Alloy Fabricated by Different Manufacturing Processes.

Authors:  Xingting Han; Tomofumi Sawada; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer; Frank Rupp; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2018-09-22       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.