Literature DB >> 24674037

Initial clinical experience with a frameless and maskless stereotactic radiosurgery treatment.

Laura I Cerviño1, Nicole Detorie2, Matthew Taylor2, Joshua D Lawson2, Taylor Harry2, Kevin T Murphy2, Arno J Mundt2, Steve B Jiang2, Todd A Pawlicki2.   

Abstract

PURPOSE: To evaluate the initial clinical experience with a frameless and maskless technique for stereotactic radiosurgery using minimal patient immobilization and real-time patient motion monitoring during treatment. We focus on the evaluation of the patient treatment process. METHODS AND MATERIALS: The study considered the first 23 patients treated with this technique. Head positioning was achieved with a patient-specific head mold made out of expandable foam that conforms to the patient's head. The face of the patient is left open for maximal comfort and so that motion of a region of interest consisting of the forehead, nose, eyes, and temporal bones can be monitored during treatment using a video surface imaging system (VisionRT Inc, London, UK). Initial setup of the patient was performed with the surface imaging system using the surface of the patient obtained from the treatment planning computed tomographic (CT) scan. The initial setup was confirmed and finalized with cone-beam CT (CBCT) prior to treatment. The shifts for final setup based on the CBCT and the duration of all the steps in the treatment process were recorded. Patients were monitored during treatment with surface imaging, and a beam hold-off was initiated when the patient's motion exceeded a prespecified tolerance.
RESULTS: The average total setup time including surface imaging and CBCT was 26 minutes, while the portion corresponding to surface imaging was 14 minutes. The average treatment time from when the patient was placed on the treatment table until the last treatment beam was 40 minutes. Eight (35%) patients needed repositioning during the treatment. The average shifts identified from CBCT after initial setup with surface imaging were 1.85 mm in the anterior-posterior direction, and less than 1.0 mm in the lateral and superior-inferior directions. The longest treatment times (including beam hold-offs) happened for patients who fell asleep on the treatment table and were moving involuntarily.
CONCLUSIONS: The frameless and maskless treatment using minimal immobilization and surface imaging has proven to be reasonably fast for routine clinical use. We observed that patient compliance is important. An additional degree of semi-rigid immobilization would be helpful for patients who fall asleep and involuntarily move during the procedure.
Copyright © 2012 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2011        PMID: 24674037     DOI: 10.1016/j.prro.2011.04.005

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  22 in total

1.  Enriching 3D optical surface scans with prior knowledge: tissue thickness computation by exploiting local neighborhoods.

Authors:  Tobias Wissel; Patrick Stüber; Benjamin Wagner; Ralf Bruder; Achim Schweikard; Floris Ernst
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-06-30       Impact factor: 2.924

2.  A new variable for SRS plan quality evaluation based on normal tissue sparing: the effect of prescription isodose levels.

Authors:  Q Zhang; D Zheng; Y Lei; B Morgan; J Driewer; M Zhang; S Li; S Zhou; W Zhen; R Thompson; A Wahl; C Lin; C Enke
Journal:  Br J Radiol       Date:  2014-09-16       Impact factor: 3.039

3.  Frameless single-isocenter intensity modulated stereotactic radiosurgery for simultaneous treatment of multiple intracranial metastases.

Authors:  Steven K M Lau; Xiao Zhao; Ruben Carmona; Erik Knipprath; Daniel R Simpson; Sameer K Nath; Gwe-Ya Kim; Jona A Hattangadi; Clark C Chen; Kevin T Murphy
Journal:  Transl Cancer Res       Date:  2014-08-01       Impact factor: 1.241

4.  Dosimetric study of the plan quality and dose to organs at risk on tangential breast treatments using the Halcyon linac.

Authors:  Everardo Flores-Martinez; Gwe-Ya Kim; Catheryn M Yashar; Laura I Cerviño
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

5.  Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases.

Authors:  Steven K M Lau; Kaveh Zakeri; Xiao Zhao; Ruben Carmona; Erik Knipprath; Daniel R Simpson; Sameer K Nath; Gwe-Ya Kim; Parag Sanghvi; Jona A Hattangadi-Gluth; Clark C Chen; Kevin T Murphy
Journal:  Neurosurgery       Date:  2015-08       Impact factor: 4.654

6.  Clinical efficacy and safety of surface imaging guided radiosurgery (SIG-RS) in the treatment of benign skull base tumors.

Authors:  Steven K M Lau; Kunal Patel; Teddy Kim; Erik Knipprath; Gwe-Ya Kim; Laura I Cerviño; Joshua D Lawson; Kevin T Murphy; Parag Sanghvi; Bob S Carter; Clark C Chen
Journal:  J Neurooncol       Date:  2017-01-24       Impact factor: 4.130

7.  Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling.

Authors:  Vance Keeling; Sabbir Hossain; Hosang Jin; Ozer Algan; Salahuddin Ahmad; Imad Ali
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

8.  Dosimetric effects of positioning shifts using 6D-frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapy.

Authors:  Hosang Jin; Vance P Keeling; Imad Ali; Salahuddin Ahmad
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

9.  Clinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring.

Authors:  Guang Li; Ase Ballangrud; Maria Chan; Ruimei Ma; Kathryn Beal; Yoshiya Yamada; Timothy Chan; James Lee; Pretti Parhar; James Mechalakos; Margie Hunt
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

10.  Development and Longitudinal Analysis of Plan-Based Streamlined Quality Assurance on Multiple Positioning Guidance Systems With Single Phantom Setup.

Authors:  Shun Zhou; Junyu Li; Yi Du; Songmao Yu; Meijiao Wang; Hao Wu; Haizhen Yue
Journal:  Front Oncol       Date:  2021-06-16       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.