Literature DB >> 24673448

Reliability and minimal detectable change of 3-dimensional scapular orientation in individuals with and without shoulder impingement.

Melina N Haik1, Francisco Alburquerque-Sendín, Paula R Camargo.   

Abstract

STUDY
DESIGN: Clinical measurement.
OBJECTIVE: To establish trial-to-trial within-day and between-day reliability, standard error of measurement, and minimal detectable change of scapular orientation during elevation and lowering of the arm, and with the arm relaxed at the side, in individuals with and without shoulder impingement.
BACKGROUND: Electromagnetic devices are commonly used to measure 3-D scapular kinematics during arm elevation in different conditions and for intervention studies. However, there is a lack of studies that evaluate within- and between-day reliability of these measurements.
METHODS: The subjects were allocated to either a control group or an impingement group. Kinematic data were collected using the Flock of Birds electromagnetic device during elevation and lowering of the arm in the sagittal plane on 2 different occasions, separated by 3 to 5 days. Forty-nine subjects were tested for within-day reliability. Forty-three subjects were reassessed for between-day reliability.
RESULTS: Intraclass correlation coefficients for within- and between-day assessment of scapular orientation during elevation and lowering of the arm in both groups ranged from 0.92 to 0.99 and from 0.54 to 0.88, respectively. Intraclass correlation coefficients for assessment of scapular orientation with the arms relaxed at the side in both groups ranged from 0.66 to 0.95. The standard error of measurement for between-day measurements ranged from 3.37° to 7.44° for both groups. The minimal detectable change for between-day measurements increased from 7.81° at the lower to 17.27° at the higher humerothoracic elevation angles.
CONCLUSION: These results support the use of Flock of Birds to measure scapular orientations in subjects with and without impingement symptoms. The measurements showed excellent within-day reliability but were not highly reliable over time.

Entities:  

Mesh:

Year:  2014        PMID: 24673448     DOI: 10.2519/jospt.2014.4705

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  9 in total

Review 1.  Collecting shoulder kinematics with electromagnetic tracking systems and digital inclinometers: A review.

Authors:  Daniel C Hannah; Jason S Scibek
Journal:  World J Orthop       Date:  2015-11-18

2.  Psychometric properties of the Brazilian version of the Bournemouth questionnaire for low back pain: validity and reliability.

Authors:  Letícia Bojikian Calixtre; Carlos Luques Fonseca; Bruno Leonardo da Silva Gruninger; Danilo Harudy Kamonseki
Journal:  Braz J Phys Ther       Date:  2020-02-24       Impact factor: 3.377

3.  Swimming Practice and Scapular Kinematics, Scapulothoracic Muscle Activity, and the Pressure-Pain Threshold in Young Swimmers.

Authors:  Fernanda A P Habechian; Ana Letícia Lozana; Ann M Cools; Paula R Camargo
Journal:  J Athl Train       Date:  2019-01-07       Impact factor: 2.860

4.  Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement.

Authors:  Dayana P Rosa; John D Borstad; Elisa D Pires; Paula R Camargo
Journal:  Braz J Phys Ther       Date:  2016-03-15       Impact factor: 3.377

5.  Normalization of the trapezius sEMG signal - a reliability study on women with and without neck-shoulder pain.

Authors:  Marina Machado Cid; Leticia Bergamin Januario; Gisele Garcia Zanca; Stela Marcia Mattiello; Ana Beatriz Oliveira
Journal:  Braz J Phys Ther       Date:  2017-09-29       Impact factor: 3.377

6.  Scapular Dyskinesis: From Basic Science to Ultimate Treatment.

Authors:  Umile Giuseppe Longo; Laura Risi Ambrogioni; Alessandra Berton; Vincenzo Candela; Carlo Massaroni; Arianna Carnevale; Giovanna Stelitano; Emiliano Schena; Ara Nazarian; Joseph DeAngelis; Vincenzo Denaro
Journal:  Int J Environ Res Public Health       Date:  2020-04-24       Impact factor: 3.390

7.  Concurrent Validity and Reliability of an Inertial Measurement Unit for the Assessment of Craniocervical Range of Motion in Subjects with Cerebral Palsy.

Authors:  Cristina Carmona-Pérez; Juan Luis Garrido-Castro; Francisco Torres Vidal; Sandra Alcaraz-Clariana; Lourdes García-Luque; Francisco Alburquerque-Sendín; Daiana Priscila Rodrigues-de-Souza
Journal:  Diagnostics (Basel)       Date:  2020-02-01

8.  Association between changes in pain or function scores and changes in scapular rotations in patients with subacromial shoulder pain: a prospective cohort study.

Authors:  Zohreh Jafarian Tangrood; Gisela Sole; Daniel Cury Ribeiro
Journal:  Arch Physiother       Date:  2022-08-15

9.  Absolute and Relative Reliability of the Assessment of the Muscle Mechanical Properties of Pelvic Floor Muscles in Women with and without Urinary Incontinence.

Authors:  Daiana Priscila Rodrigues-de-Souza; Sandra Alcaraz-Clariana; Lourdes García-Luque; Cristina Carmona-Pérez; Juan Luis Garrido-Castro; Inés Cruz-Medel; Paula R Camargo; Francisco Alburquerque-Sendín
Journal:  Diagnostics (Basel)       Date:  2021-12-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.