Literature DB >> 24666808

Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units.

Siobhan M Lucey1, Ario Santini, Elizabeth M Roebuck.   

Abstract

BACKGROUND: There is a lack of data on polymerization of resin-based materials (RBMs) used in paediatric dentistry, using dual-peak light-emitting diode (LED) light-curing units (LCUs).
OBJECTIVE: To evaluate the degree of conversion (DC) of RBMs cured with dual-peak or single-peak LED LCUs.
METHODS: Samples of Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) and fissure sealants Delton Clear and Delton Opaque (Dentsply) were prepared (n = 3 per group) and cured with either one of two dual-peak LCUs (bluephase(®) G2; Ivoclar Vivadent or Valo; Ultradent) or a single-peak (bluephase(®) ; Ivoclar Vivadent). High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of initiators other than camphorquinone. The DC was determined using micro-Raman spectroscopy. Data were analysed using general linear model anova; α = 0.05.
RESULTS: With Herculite XRV Ultra, the single-peak LCU gave higher DC values than either of the two dual-peak LCUs (P < 0.05). Both fissure sealants showed higher DC compared with the two RBMs (P < 0.05); the DC at the bottom of the clear sealant was greater than the opaque sealant, (P < 0.05). 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin(®) TPO) was found only in Vit-l-escence.
CONCLUSIONS: Dual-peak LED LCUs may not be best suited for curing non-Lucirin(®) TPO-containing materials. A clear sealant showed a better cure throughout the material and may be more appropriate than opaque versions in deep fissures.
© 2014 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24666808     DOI: 10.1111/ipd.12104

Source DB:  PubMed          Journal:  Int J Paediatr Dent        ISSN: 0960-7439            Impact factor:   3.455


  2 in total

1.  Effects of 3 different light-curing units on the physico-mechanical properties of bleach-shade resin composites.

Authors:  Azin Farzad; Shahin Kasraei; Sahebeh Haghi; Mahboubeh Masoumbeigi; Hassan Torabzadeh; Narges Panahandeh
Journal:  Restor Dent Endod       Date:  2022-02-07

2.  Effect of Curing Modes on the Mechanical Properties of Commercial Dental Resin-Based Composites: Comparison between Different LEDs and Microwave Units.

Authors:  Alef Vermudt; Milton Carlos Kuga; João Felipe Besegato; Eliane Cristina Gulin de Oliveira; Thaís Piragine Leandrin; Marcus Vinicius Reis Só; João Carlos Silos Moraes; Jefferson Ricardo Pereira
Journal:  Polymers (Basel)       Date:  2022-09-26       Impact factor: 4.967

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.