Literature DB >> 24665048

Rates of in vivo (arterial) and in vitro biocorrosion for pure magnesium.

Patrick K Bowen1, Adam Drelich, Jaroslaw Drelich, Jeremy Goldman.   

Abstract

The development of magnesium-based materials for bioabsorbable stents relies heavily on corrosion testing by immersion in pseudophysiological solutions, where magnesium degrades faster than it does in vivo. The quantitative difference in corrosion kinetics in vitro and in vivo is largely unknown, but, if determined, would help reduce dependence on animal models. In order to create a quantitative in vitro-in vivo correlation based on an accepted measure of corrosion (penetration rate), commercially pure magnesium wires were corroded in vivo in the abdominal aortas of rats for 5-32 days, and in vitro for up to 14 days using Dulbecco's modified eagle medium. Cross-sectioning, scanning electron microscopy, image analysis, a modified penetration rate tailored to degraded wires, and empirical modeling were used to analyze the corroded specimens. In vitro penetration rates were consistently higher than comparable in vivo rates by a factor of 1.2-1.9× (±0.2×). For a sample <20% corroded, an approximate in vitro-in vivo multiplier of 1.3 ± 0.2× was applied, whereas a multiplier of 1.8 ± 0.2× became appropriate when the magnesium specimen was 25-35% degraded.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  biodegradation; implant; in vitro test; in vivo test; magnesium; stent

Mesh:

Substances:

Year:  2014        PMID: 24665048     DOI: 10.1002/jbm.a.35179

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  15 in total

1.  In vitro biodegradation behavior, mechanical properties, and cytotoxicity of biodegradable Zn-Mg alloy.

Authors:  Haibo Gong; Kun Wang; Randy Strich; Jack G Zhou
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-01-08       Impact factor: 3.368

2.  Novel high-strength, low-alloys Zn-Mg (<0.1wt% Mg) and their arterial biodegradation.

Authors:  Hualan Jin; Shan Zhao; Roger Guillory; Patrick K Bowen; Zhiyong Yin; Adam Griebel; Jeremy Schaffer; Elisha J Earley; Jeremy Goldman; Jaroslaw W Drelich
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-11-21       Impact factor: 7.328

3.  Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

Authors:  Adam J Drelich; Shan Zhao; Roger J Guillory; Jaroslaw W Drelich; Jeremy Goldman
Journal:  Acta Biomater       Date:  2017-05-19       Impact factor: 8.947

4.  In Vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc.

Authors:  Emily R Shearier; Patrick K Bowen; Weilue He; Adam Drelich; Jaroslaw Drelich; Jeremy Goldman; Feng Zhao
Journal:  ACS Biomater Sci Eng       Date:  2016-03-14

Review 5.  A review of current challenges and prospects of magnesium and its alloy for bone implant applications.

Authors:  Meysam Nasr Azadani; Abolfazl Zahedi; Oluwole Kingsley Bowoto; Bankole Ibrahim Oladapo
Journal:  Prog Biomater       Date:  2022-03-03

Review 6.  Magnesium-based materials in orthopaedics: material properties and animal models.

Authors:  Xirui Jing; Qiuyue Ding; Qinxue Wu; Weijie Su; Keda Yu; Yanlin Su; Bing Ye; Qing Gao; Tingfang Sun; Xiaodong Guo
Journal:  Biomater Transl       Date:  2021-09-28

Review 7.  Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn-Alloys.

Authors:  Patrick K Bowen; Emily R Shearier; Shan Zhao; Roger J Guillory; Feng Zhao; Jeremy Goldman; Jaroslaw W Drelich
Journal:  Adv Healthc Mater       Date:  2016-04-20       Impact factor: 9.933

8.  Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents.

Authors:  Patrick K Bowen; Roger J Guillory; Emily R Shearier; Jan-Marten Seitz; Jaroslaw Drelich; Martin Bocks; Feng Zhao; Jeremy Goldman
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-07-16       Impact factor: 7.328

9.  Sealing the Pores of PEO Coating with Mg-Al Layered Double Hydroxide: Enhanced Corrosion Resistance, Cytocompatibility and Drug Delivery Ability.

Authors:  Feng Peng; Donghui Wang; Yaxin Tian; Huiliang Cao; Yuqin Qiao; Xuanyong Liu
Journal:  Sci Rep       Date:  2017-08-15       Impact factor: 4.379

10.  In vitro corrosion of pure magnesium and AZ91 alloy-the influence of thin electrolyte layer thickness.

Authors:  Rong-Chang Zeng; Wei-Chen Qi; Fen Zhang; Shuo-Qi Li
Journal:  Regen Biomater       Date:  2016-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.