Literature DB >> 2466397

MR imaging artifacts of the axial internal anatomy of the cervical spinal cord.

A J Curtin1, D W Chakeres, R Bulas, C P Boesel, M Finneran, E Flint.   

Abstract

Transverse scans of the spinal cord routinely demonstrate signal variations related to the internal anatomy of the cord that do not accurately conform to histologic cross sections. This study evaluates the MR appearance of the axial anatomy of the spinal cord and provides correlation to histologic sections as a means to understand this discordance so that disease can be recognized more readily. Short TR/TE spin-echo studies, cardiac-gated multiecho spin-echo studies, and gradient-refocused-echo studies of normal excised human spinal cords, a normal volunteer, and gelatin phantoms were obtained by using the same imaging parameters at 1.5 T. Imaging artifacts were further investigated by using both a 128 x 256 and 256 x 256 matrix with a varying phase-encoded axis. Histologic sections of the excised cords, which were stained for myelin, iron, and cell bodies (Nissl), were used for correlation to the images. We found that significant Fourier truncation and partial-volume imaging artifacts modulated the MR display of the cord. On short TR/TE images a ring of high signal at the periphery of the cord was due to a truncation artifact. The appearance of the central portions of the gray and white matter was affected variably by partial-volume averaging depending on the matrix size. White-matter tracts of the cord were always lower in signal than was the gray matter on all pulse sequences. This finding was not due to iron deposition or CSF motion artifacts. We suspect that this probably was related to dense, longitudinal organization of spinal tracts and resultant anisotropy of water molecule motion similar to that seen in the pyramidal tracts, tendons, and ligaments. We recommend the use of a 128 x 256 matrix with two averages (four excitations) when obtaining axial scans of the spinal cord in living subjects. Although truncation artifacts diminish image quality, the quality is superior to that of images obtained with a 256 x 256 matrix, in which longer scanning times result in motion artifacts and reduced signal to noise.

Entities:  

Mesh:

Year:  1989        PMID: 2466397     DOI: 10.2214/ajr.152.4.835

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Functional MR imaging of the human cervical spinal cord.

Authors:  S Madi; A E Flanders; S Vinitski; G J Herbison; J Nissanov
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

Review 2.  Current and Emerging Therapies in Multiple Sclerosis: Implications for the Radiologist, Part 1-Mechanisms, Efficacy, and Safety.

Authors:  C McNamara; G Sugrue; B Murray; P J MacMahon
Journal:  AJNR Am J Neuroradiol       Date:  2017-04-13       Impact factor: 3.825

3.  Automatic magnetic resonance spinal cord segmentation with topology constraints for variable fields of view.

Authors:  Min Chen; Aaron Carass; Jiwon Oh; Govind Nair; Dzung L Pham; Daniel S Reich; Jerry L Prince
Journal:  Neuroimage       Date:  2013-08-06       Impact factor: 6.556

4.  Central spinal cord lesions in stenosis of the cervical canal.

Authors:  J H Faiss; G Schroth; W Grodd; E Koenig; B Will; A Thron
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

5.  Magnetic resonance imaging of spinal pyramidal tract degeneration in amyotrophic lateral sclerosis.

Authors:  S Terao; G Sobue; T Yasuda; T Kachi; N Shimada; C Oguri; T Mitsuma
Journal:  J Neurol       Date:  1995-02       Impact factor: 4.849

6.  Axial 3D gradient-echo imaging for improved multiple sclerosis lesion detection in the cervical spinal cord at 3T.

Authors:  Arzu Ozturk; Nafi Aygun; Seth A Smith; Brian Caffo; Peter A Calabresi; Daniel S Reich
Journal:  Neuroradiology       Date:  2012-12-04       Impact factor: 2.804