The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro.

L T Blouin1, F I Marcus.   

Abstract

Four types of electrodes were studied with respect to efficiency of delivery of radiofrequency energy (RFE) and characteristics of the lesions produced in dog ventricular muscle in vitro. An imbeddable needle electrode was found to be the most efficient of the four types studied, with a lesion volume/energy-delivered ratio of 1.10 mm3/joule at an optimum power level of 2.8 watts and power density at the electrode surface of 0.45 watt/mm2. Lesion volume was linearly related to energy delivered at all power levels used below a power density of 0.64 watt/mm2, at and above which tissue impedance increased abruptly. The electrode catheter typically used for RFE ablations was the least efficient at 0.15 mm3/joule and a power density at the electrode surface of 0.50 watt/mm2 at 6.27 watts. masking 2/3 of the electrode surface with electrically insulating epoxy caused the RFE current to be directed into the tissue, resulting in a threefold increase in efficiency (0.46 mm3/joule) at less than half the power (2.79 watts). A flat, thermally insulated electrode with larger (10 mm2) contact area approached the efficiency of the imbedded electrode with a ratio of 0.69 mm3/joule at a low power density of 0.19 watt/mm2 and 1.85 watt power level. Characteristics of an "ideal" electrode for RFE lesion production in cardiac tissue are discussed.

Entities:  

Mesh:

Year:  1989        PMID: 2466246     DOI: 10.1111/j.1540-8159.1989.tb02640.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Epicardial radiofrequency ablation of ventricular myocardium: factors affecting lesion formation and damage to adjacent structures.

Authors:  Guilherme Fenelon; Kleber Ponzi Pereira; Angelo A V de Paola
Journal:  J Interv Card Electrophysiol       Date:  2006-01       Impact factor: 1.900

2.  Modelling of myocardial temperature distribution during radio-frequency ablation.

Authors:  Z Kaouk; A Vahid Shahidi; P Savard; F Molin
Journal:  Med Biol Eng Comput       Date:  1996-03       Impact factor: 2.602

3.  Effect of catheter tip length and position on lesion volume in temperature controlled RF ablation in canine tricuspid valve annulus.

Authors:  A Mehdirad; J Gaiser; P Baker; S West; L Lehmkuhl; P Yong; J Meimer; S Nelson
Journal:  J Interv Card Electrophysiol       Date:  1998-09       Impact factor: 1.900

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.