Literature DB >> 24662097

Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging.

Yoshinori Funama1, Katsuyuki Taguchi2, Daisuke Utsunomiya3, Seitaro Oda3, Kazuhiro Katahira4, Shinichi Tokuyasu5, Yasuyuki Yamashita3.   

Abstract

PURPOSE: To compare the noise and accuracy on images of the whole porcine liver acquired with iterative reconstruction (IMR, Philips Healthcare, Cleveland, OH, USA) and filtered back projection (FBP) methods.
MATERIALS AND METHODS: We used non-enhanced porcine liver to simulate the human liver and acquired it 100 times to obtain the average FBP value as the ground-truth. The mean and the standard deviation ("inter-scan SD") of the pixel values on the 100 image acquisitions were calculated for FBP and for three levels of IMR (L1, L2, and L3). We also calculated the noise power spectrum (NPS) and the normalized NPS for the 100 image acquisitions.
RESULTS: The spatial SD for the porcine liver parenchyma on these slices was 9.92, 4.37, 3.63, and 2.30 Hounsfield units with FBP, IMR-L1, IMR-L2, and IMR-L3, respectively. The detectability of small faint features was better on single IMR than single FBP images. The inter-scan SD value for IMR-L3 images was 53% larger at the liver edges than at the liver parenchyma; it was only 10% larger on FBP images. Assessment of the normalized NPS showed that the noise on IMR images was comprised primarily of low-frequency components.
CONCLUSION: IMR images yield the same structure informations as FBP images and image accuracy is maintained. On level 3 IMR images the image noise is more strongly suppressed than on IMR images of the other levels and on FBP images.
Copyright © 2014. Published by Elsevier Ltd.

Entities:  

Keywords:  Abdominal CT; Filtered back projection; Image quality; Iterative reconstruction; Porcine liver

Mesh:

Year:  2014        PMID: 24662097      PMCID: PMC6347105          DOI: 10.1016/j.ejmp.2014.02.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  9 in total

1.  Knowledge-based iterative model reconstruction: comparative image quality and radiation dose with a pediatric computed tomography phantom.

Authors:  Young Jin Ryu; Young Hun Choi; Jung-Eun Cheon; Seongmin Ha; Woo Sun Kim; In-One Kim
Journal:  Pediatr Radiol       Date:  2015-11-06

Review 2.  Local and Non-local Regularization Techniques in Emission (PET/SPECT) Tomographic Image Reconstruction Methods.

Authors:  Munir Ahmad; Tasawar Shahzad; Khalid Masood; Khalid Rashid; Muhammad Tanveer; Rabail Iqbal; Nasir Hussain; Abubakar Shahid
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

3.  Improved Estimation of Coronary Plaque and Luminal Attenuation Using a Vendor-specific Model-based Iterative Reconstruction Algorithm in Contrast-enhanced CT Coronary Angiography.

Authors:  Yoshinori Funama; Daisuke Utsunomiya; Kenichiro Hirata; Katsuyuki Taguchi; Takeshi Nakaura; Seitaro Oda; Masafumi Kidoh; Hideaki Yuki; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2017-04-07       Impact factor: 3.173

4.  Iterative reconstruction with multifrequency signal recognition technology to improve low-contrast detectability: A phantom study.

Authors:  Yoshinori Funama; Takashi Shirasaka; Taiga Goto; Yuko Aoki; Kana Tanaka; Ryo Yoshida
Journal:  Acta Radiol Open       Date:  2022-06-17

5.  Fully automated image quality evaluation on patient CT: Multi-vendor and multi-reconstruction study.

Authors:  Minsoo Chun; Jin Hwa Choi; Sihwan Kim; Chulkyun Ahn; Jong Hyo Kim
Journal:  PLoS One       Date:  2022-07-20       Impact factor: 3.752

6.  Low dose dynamic myocardial CT perfusion using advanced iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Christopher Fuqua; Mani Vembar; Amar Dhanantwari; Hiram G Bezerra; David L Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-19

7.  Improved scan method for dental imaging using multidetector computed tomography: a phantom study.

Authors:  Yuki Sakai; Kazutoshi Okamura; Erina Kitamoto; Yukiko N Kami; Takashi Shirasaka; Ryoji Mikayama; Masato Tatsumi; Masatoshi Kondo; Toyoyuki Kato; Kazunori Yoshiura
Journal:  Dentomaxillofac Radiol       Date:  2020-04-29       Impact factor: 2.419

8.  Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction.

Authors:  R H H Wellenberg; M F Boomsma; J A C van Osch; A Vlassenbroek; J Milles; M A Edens; G J Streekstra; C H Slump; M Maas
Journal:  Skeletal Radiol       Date:  2017-02-15       Impact factor: 2.199

9.  Quantitative and qualitative evaluation of hybrid iterative reconstruction, with and without noise power spectrum models: A phantom study.

Authors:  Kazuya Minamishima; Koichi Sugisawa; Yoshitake Yamada; Masahiro Jinzaki
Journal:  J Appl Clin Med Phys       Date:  2018-02-28       Impact factor: 2.102

  9 in total