Literature DB >> 24660204

Consensus statements and clinical recommendations for implant loading protocols.

German O Gallucci, Goran I Benic, Steven E Eckert, Panos Papaspyridakos, Martin Schimmel, Alexander Schrott, Hans-Peter Weber.   

Abstract

Mesh:

Year:  2014        PMID: 24660204     DOI: 10.11607/jomi.2013.g4

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


× No keyword cloud information.
  22 in total

1.  Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

Authors:  Kıvanç Akça; Atılım Eser; Yeliz Çavuşoğlu; Elçin Sağırkaya; Murat Cavit Çehreli
Journal:  Med Biol Eng Comput       Date:  2015-03-01       Impact factor: 2.602

2.  Review finds failure rates lower for delayed loaded submerged dental implants.

Authors:  David McReynolds; Brett Duane
Journal:  Evid Based Dent       Date:  2015-12

Review 3.  Factors affecting the complexity of dental implant restoration - what is the current evidence and guidance?

Authors:  S P Wright; J Hayden; J A Lynd; K Walker-Finch; J Willett; C Ucer; S D Speechley
Journal:  Br Dent J       Date:  2016-11-18       Impact factor: 1.626

4.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

5.  Can Low-Level Laser and Light-Emitting Diode Enhance the Stability of Dental Implants?

Authors:  Hassan Mohajerani; Abolfazl Mohammad Salehi; Faraj Tabeie; Shervin Shafiei; Reza Tabrizi
Journal:  J Maxillofac Oral Surg       Date:  2019-03-29

6.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

7.  Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

Authors:  Corina Marilena Cristache; Silviu Gurbanescu
Journal:  Int J Dent       Date:  2017-05-07

8.  Survival and Complications of Single Dental Implants in the Edentulous Mandible Following Immediate or Delayed Loading: A Randomized Controlled Clinical Trial.

Authors:  M Kern; W Att; E Fritzer; S Kappel; R G Luthardt; T Mundt; D R Reissmann; M Rädel; M Stiesch; S Wolfart; N Passia
Journal:  J Dent Res       Date:  2017-10-18       Impact factor: 6.116

Review 9.  Consensus statements and clinical recommendations on treatment indications, surgical procedures, prosthetic protocols and complications following All-On-4 standard treatment. 9th Mozo-Grau Ticare Conference in Quintanilla, Spain.

Authors:  Miguel Penarrocha-Diago; María Penarrocha-Diago; Regino Zaragozí-Alonso; David Soto-Penaloza; Meeting On Behalf Of The Ticare Consensus
Journal:  J Clin Exp Dent       Date:  2017-05-01

10.  Comparative evaluation of the influence of immediate versus delayed loading protocols of dental implants: A radiographic and clinical study.

Authors:  Amrit Tandan; Viram Upadhyaya; Mohit Raghuvanshi
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.