Literature DB >> 24658516

Biocompatibility Assessment of the CentriMag-Novalung Adult ECMO Circuit in a Model of Acute Pulmonary Hypertension.

Venkat Shankarraman1, Ergin Kocyildirim, Salim E Olia, Marina V Kameneva, Ryan J Dzadony, Timothy M Maul, Marc A Simon, Hunter C Champion, William R Wagner, Christian A Bermudez.   

Abstract

Extracorporeal membrane oxygenation (ECMO) is rarely used in patients with severe pulmonary hypertension (PH) as a bridge to lung transplantation. In this study, we assess the blood biocompatibility of the integrated CentriMag-Novalung ECMO system (venoarterial) in an acute model of PH. Severe PH (≥2/3 systemic) was induced in eight sheep through progressive ligation of the main pulmonary artery. System performance, platelet activation, thromboelastography (TEG) parameters, fibrinogen, plasma-free hemoglobin, and total plasma protein were measured at initiation, 3, and 6 hr of support in the ECMO (N = 4) and sham (N = 4) groups. A stable ECMO flow (2.2 ± 0.1 L/min), low transmembrane pressure gradient, and steady blood O2 and CO2 levels were maintained. Platelet activation was low (<4%) in both the groups, whereas platelet responsiveness to agonist (platelet activating factor) was reduced in the sham group when compared with the ECMO group. There were no differences in the TEG parameters, fibrinogen concentration, plasma-free hemoglobin (<10 mg/dl), and plasma total protein between the two groups. The findings of low levels of platelet activation and plfHb suggest adequate blood biocompatibility of the integrated CentriMag-Novalung circuit use for short-term support in a model of PH.

Entities:  

Mesh:

Year:  2014        PMID: 24658516      PMCID: PMC4320026          DOI: 10.1097/MAT.0000000000000079

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  35 in total

1.  Description of a flow optimized oxygenator with integrated pulsatile pump.

Authors:  Ralf Borchardt; Peter Schlanstein; Jutta Arens; Roland Graefe; Fabian Schreiber; Thomas Schmitz-Rode; Ulrich Steinseifer
Journal:  Artif Organs       Date:  2010-11       Impact factor: 3.094

2.  Single double-lumen venous-venous pump-driven extracorporeal lung membrane support.

Authors:  David Sanchez-Lorente; Tetsuhiko Go; Philipp Jungebluth; Irene Rovira; Maite Mata; Maria Carme Ayats; Paolo Macchiarini
Journal:  J Thorac Cardiovasc Surg       Date:  2010-09       Impact factor: 5.209

3.  Flow cytometric assays for quantifying activated ovine platelets.

Authors:  Carl A Johnson; Trevor A Snyder; Joshua R Woolley; William R Wagner
Journal:  Artif Organs       Date:  2007-11-14       Impact factor: 3.094

4.  Life-threatening right ventricular failure in pulmonary hypertension: RVAD or ECMO?

Authors:  Marius Berman; Steven Tsui; Alain Vuylsteke; Andrew Klein; David P Jenkins
Journal:  J Heart Lung Transplant       Date:  2008-10       Impact factor: 10.247

Review 5.  Anticoagulation and coagulation management for ECMO.

Authors:  William C Oliver
Journal:  Semin Cardiothorac Vasc Anesth       Date:  2009-09

6.  Hemocompatibility of a miniaturized extracorporeal membrane oxygenation and a pumpless interventional lung assist in experimental lung injury.

Authors:  Ruedger Kopp; Ralf Bensberg; Dietrich Henzler; Anja Niewels; Simone Randerath; Rolf Rossaint; Ralf Kuhlen
Journal:  Artif Organs       Date:  2009-10-11       Impact factor: 3.094

7.  Platelet activation in ovines undergoing sham surgery or implant of the second generation PediaFlow pediatric ventricular assist device.

Authors:  Carl A Johnson; Peter D Wearden; Ergin Kocyildirim; Timothy M Maul; Joshua R Woolley; Sang-Ho Ye; Elise M Strickler; Harvey S Borovetz; William R Wagner
Journal:  Artif Organs       Date:  2011-04-05       Impact factor: 3.094

8.  Extracorporeal membrane oxygenation for primary graft dysfunction after lung transplantation: long-term survival.

Authors:  Christian A Bermudez; Prasad S Adusumilli; Kenneth R McCurry; Diana Zaldonis; Maria M Crespo; Joseph M Pilewski; Yoshiya Toyoda
Journal:  Ann Thorac Surg       Date:  2009-03       Impact factor: 4.330

9.  New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.

Authors:  Tatsuki Fujiwara; Eiki Nagaoka; Taiju Watanabe; Naoto Miyagi; Takashi Kitao; Daisuke Sakota; Taichi Mamiya; Tadahiko Shinshi; Hirokuni Arai; Setsuo Takatani
Journal:  Artif Organs       Date:  2013-03-13       Impact factor: 3.094

10.  Platelets in pulmonary hypertension: a causative role or a simple association?

Authors:  Keyhan Sayadpour Zanjani
Journal:  Iran J Pediatr       Date:  2012-06       Impact factor: 0.364

View more
  2 in total

1.  Using Daily Plasma-Free Hemoglobin Levels for Diagnosis of Critical Pump Thrombus in Patients Undergoing ECMO or VAD Support.

Authors:  James R Neal; Eduard Quintana; Roxann B Pike; James D Hoyer; Lyle D Joyce; Gregory Schears
Journal:  J Extra Corpor Technol       Date:  2015-06

2.  Hemocompatibility of new magnetically-levitated centrifugal pump technology compared to the CentriMag adult pump.

Authors:  David Schibilsky; Setsuo Takatani; Barbara Schibilsky; Tobias Graf; Diana Michels da Silva; Hans Peter Wendel; Meltem Avci-Adali; Christian Schlensak
Journal:  Sci Rep       Date:  2020-12-16       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.