| Literature DB >> 24656637 |
Kerim Sariyilmaz1, Fatih Dikici1, Goksel Dikmen1, Ergun Bozdag2, Emin Sunbuloglu2, Bugra Bekler2, Onder Yazicioglu1.
Abstract
The aim of this study is to assess the biomechanical advantage of adding strut allograft and the effect of its position on the construct in Vancouver type B1 fractures. Fifteen forth-generation synthetic femurs were used and created a fracture model at the tip of prosthesis, and subsequently fixated with a lateral plate only, lateral plate and medial strut, lateral plate and anterior strut. Rotational and axial tests were performed. In all loading tests, the plate with medial strut group was stiffer than the other constructs and had higher failure load values and had less displacement in the fracture site. A combination of a plate with a medial strut allograft provides more mechanical stability on periprosthetic femoral fractures near the tip of a total hip arthroplasty.Entities:
Keywords: Vancouver type B1; biomechanical; periprosthetic; strut allograft
Mesh:
Year: 2014 PMID: 24656637 DOI: 10.1016/j.arth.2014.02.017
Source DB: PubMed Journal: J Arthroplasty ISSN: 0883-5403 Impact factor: 4.757