Literature DB >> 24656541

Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds.

Alexandre Grand-Guillaume Perrenoud1, Jean-Luc Veuthey1, Davy Guillarme2.   

Abstract

The recent market release of a new generation of supercritical fluid chromatography (SFC) instruments compatible with state-of-the-art columns packed with sub-2μm particles (UHPSFC) has contributed to the reemergence of interest in this technology at the analytical scale. However, to ensure performance competitiveness of this technique with modern analytical standards, a robust hyphenation of UHPSFC to mass spectrometry (MS) is mandatory. UHPSFC-MS hyphenation interface should be able to manage the compressibility of the SFC mobile phase and to preserve as much as possible the chromatographic separation integrity. Although several interfaces can be envisioned, each will have noticeable effects on chromatographic fidelity, flexibility and user-friendliness. In the present study, various interface configurations were evaluated in terms of their impact on chromatographic efficiency and MS detection sensitivity. An interface including a splitter and a make-up solvent inlet was found to be the best compromise and exhibited good detection sensitivity while maintaining more than 75% of the chromatographic efficiency. This interface was also the most versatile in terms of applicable analytical conditions. In addition, an accurate model of the fluidics behavior of this interface was created for a better understanding of the influence of chromatographic settings on its mode of operation. In the second part, the most influential experimental factors affecting MS detection sensitivity were identified and optimized using a design-of-experiment approach. The application of low capillary voltage and high desolvation temperature and drying gas flow rate were required for optimal ESI ionization and nebulization processes. The detection sensitivity achieved using the maximized UHPSFC-ESI-MS/MS conditions for a mixture of basic pharmaceutical compounds showed 4- to 10-fold improvements in peak intensity compared to the best performance achieved by UHPLC-ESI-MS/MS with the same MS detector.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Detection sensitivity; Interfacing approach; Pharmaceutical application; SFC–MS; UHPSFC–MS

Mesh:

Substances:

Year:  2014        PMID: 24656541     DOI: 10.1016/j.chroma.2014.03.006

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Portable, Battery Operated Capillary Electrophoresis with Optical Isomer Resolution Integrated with Ionization Source for Mass Spectrometry.

Authors:  Mehdi Moini; Christopher M Rollman
Journal:  J Am Soc Mass Spectrom       Date:  2015-12-07       Impact factor: 3.109

Review 2.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

3.  Ultraperformance convergence chromatography-high resolution tandem mass spectrometry for lipid biomarker profiling and identification.

Authors:  Jace W Jones; Claire L Carter; Fei Li; Jianshi Yu; Keely Pierzchalski; Isabel L Jackson; Zeljko Vujaskovic; Maureen A Kane
Journal:  Biomed Chromatogr       Date:  2016-09-29       Impact factor: 1.902

Review 4.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

5.  Ultra-high-performance supercritical fluid chromatography with quadrupole-time-of-flight mass spectrometry (UHPSFC/QTOF-MS) for analysis of lignin-derived monomeric compounds in processed lignin samples.

Authors:  Jens Prothmann; Mingzhe Sun; Peter Spégel; Margareta Sandahl; Charlotta Turner
Journal:  Anal Bioanal Chem       Date:  2017-10-13       Impact factor: 4.142

6.  Rapid Simultaneous Quantification of 1-Formyl-2,2-Dimethylhydrazine and Dimethylurea Isomers in Environmental Samples by Supercritical Fluid Chromatography-Tandem Mass Spectrometry.

Authors:  Denis V Ovchinnikov; Sergey A Vakhrameev; Danil I Falev; Nikolay V Ul'yanovskii; Dmitry S Kosyakov
Journal:  Molecules       Date:  2022-08-07       Impact factor: 4.927

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.