PET/MR imaging in the detection and characterization of pulmonary lesions: technical and diagnostic evaluation in comparison to PET/CT.

Isabel Rauscher1, Matthias Eiber, Sebastian Fürst, Michael Souvatzoglou, Stephan G Nekolla, Sibylle I Ziegler, Ernst J Rummeny, Markus Schwaiger, Ambros J Beer.   

Abstract

UNLABELLED: Fully integrated PET/MR imaging holds great promise as a novel hybrid imaging modality in oncology and might offer advantages to PET/CT in many instances, especially because of the superior soft-tissue contrast of MR imaging, compared with CT. However, lung metastases are a frequent finding in oncologic patients, and for imaging of the lung CT is still the modality of choice. Thus, we prospectively evaluated differences in quality, detection rate, size, and radiotracer uptake of pulmonary lesions in (18)F-FDG PET/CT and PET/MR imaging.
METHODS: Institutional review board approval and informed consent were obtained. Forty patients (23 men, 17 women; mean age ± SD, 53.2 ± 13.1 y) underwent a single-injection dual-imaging protocol with (18)F-FDG PET/CT and PET/MR imaging. Pulse sequences for the lung included T1-weighted VIBE (volumetric interpolated breath-hold examination) Dixon for attenuation correction and contrast-enhanced VIBE pulse sequences. All patients underwent a diagnostic CT of the chest in deep inspiration, which also served as a standard of reference. Two masked readers assessed in consensus all images randomly concerning quality, detection, standardized uptake value (SUV), and size of pulmonary nodules. Correlations were performed using linear correlation.
RESULTS: Overall, 47 pulmonary lesions (mean size ± SD, 10.0 ± 11.4 mm; range, 2-60 mm) in 25 of 40 patients were detected. The PET datasets of PET/MR imaging and PET/CT revealed 22 of 47 pulmonary lesions with focal (18)F-FDG uptake. SUVs of lung lesions in PET/MR imaging and PET/CT correlated significantly (R = 0.9; P = 0.0001) and showed no significant difference (mean SUV PET/MR imaging, 6.3; PET/CT, 5.1; P = 0.388). There was a significantly lower image quality comparing Dixon and VIBE sequence with CT whereas PET from PET/CT and PET from PET/MR imaging showed the same results (2.8). Dixon images detected 15 of 47 lung lesions whereas VIBE images detected 32 of 47 lesions, respectively. The detection rates for small lung lesions less than 1 cm in diameter (n = 33) of MR imaging was significantly lower, with a detection rate of 9 of 33 for the Dixon sequence and 15 of 33 for the VIBE sequence (P < 0.0001 for VIBE and Dixon sequence). There was a high correlation of pulmonary lesion size of CT versus VIBE (R = 0.97).
CONCLUSION: PET image quality and detection rate of (18)F-FDG-positive lung lesions in PET/MR imaging is equivalent to PET/CT despite differences in attenuation-correction techniques. Additionally, a high linear correlation coefficient in the SUVs for the PET images from PET/CT and PET/MR imaging was found. The detection rate of lung lesions can be significantly improved by adding a diagnostic contrast-enhanced VIBE sequence to the PET/MR imaging protocol. However, the detection rate of small lung lesions is still inferior, compared with PET/CT with diagnostic CT of the chest.

Entities:  

Keywords:  computed tomography; hybrid imaging; magnetic resonance imaging; positron emission tomography; pulmonary lesion

Mesh:

Substances:

Year:  2014        PMID: 24652827     DOI: 10.2967/jnumed.113.129247

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  39 in total

1.  PET/MRI and PET/CT: is there room for both at the top of the food chain?

Authors:  Torsten Kuwert; Philipp Ritt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-11-19       Impact factor: 9.236

2.  Comments on characterization of solitary pulmonary nodules with 18F-FDG PET/CT relative activity distribution analysis.

Authors:  Orazio Schillaci; Ferdinando F Calabria
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

Review 3.  Clinical pediatric positron emission tomography/magnetic resonance program: a guide to successful implementation.

Authors:  Sandra Saade-Lemus; Elad Nevo; Iman Soliman; Hansel J Otero; Ralph W Magee; Elizabeth T Drum; Lisa J States
Journal:  Pediatr Radiol       Date:  2020-02-19

4.  Evaluation of 68Ga-DOTATOC PET/MRI for whole-body staging of neuroendocrine tumours in comparison with 68Ga-DOTATOC PET/CT.

Authors:  Lino M Sawicki; Cornelius Deuschl; Karsten Beiderwellen; Verena Ruhlmann; Thorsten D Poeppel; Philipp Heusch; Harald Lahner; Dagmar Führer; Andreas Bockisch; Ken Herrmann; Michael Forsting; Gerald Antoch; Lale Umutlu
Journal:  Eur Radiol       Date:  2017-04-24       Impact factor: 5.315

5.  Prospective head-to-head comparison of 11C-choline-PET/MR and 11C-choline-PET/CT for restaging of biochemical recurrent prostate cancer.

Authors:  Matthias Eiber; Isabel Rauscher; Michael Souvatzoglou; Tobias Maurer; Markus Schwaiger; Konstantin Holzapfel; Ambros J Beer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-08-12       Impact factor: 9.236

Review 6.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

7.  The foundation layer of quantitative cardiac PET/MRI: Attenuation correction. Again.

Authors:  Stephan G Nekolla; Jorge Cabello
Journal:  J Nucl Cardiol       Date:  2016-02-23       Impact factor: 5.952

Review 8.  PET/MR: Yet another Tesla?

Authors:  Markus Schwaiger; Karl Kunze; Christoph Rischpler; Stephan G Nekolla
Journal:  J Nucl Cardiol       Date:  2016-09-22       Impact factor: 5.952

9.  PET/MRI assessment of lung nodules in primary abdominal malignancies: sensitivity and outcome analysis.

Authors:  Pierpaolo Biondetti; Mark G Vangel; Rita M Lahoud; Felipe S Furtado; Bruce R Rosen; David Groshar; Lina G Canamaque; Lale Umutlu; Eric W Zhang; Umar Mahmood; Subba R Digumarthy; Jo-Anne O Shepard; Onofrio A Catalano
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-01-07       Impact factor: 9.236

Review 10.  18F-FDG PET/CT and PET/MRI Perform Equally Well in Cancer: Evidence from Studies on More Than 2,300 Patients.

Authors:  Claudio Spick; Ken Herrmann; Johannes Czernin
Journal:  J Nucl Med       Date:  2016-01-07       Impact factor: 10.057

View more