Literature DB >> 24652617

Point-of-care fluorescence immunoassay for cardiac panel biomarkers.

Tae Kyum Kim1, Sang Wook Oh, Soon Cheol Hong, Young Joon Mok, Eui Yul Choi.   

Abstract

BACKGROUND: Myoglobin, creatine kinase-MB isoenzyme (CK-MB), and cardiac troponin I (cTnI) are cardiac biomarkers that are widely used to assist in the early and late diagnoses of acute myocardial infarction (AMI). Here, we present a clinically applicable fluorescence (FL) immunoassay for cardiac biomarkers.
METHODS: Whole blood was mixed with FL-labeled detector Ab (antibody) and then loaded onto a capture Ab-immobilized strip in a test cartridge. The FL intensities at test and control line on the strip were obtained and converted in a laser FL scanner to determine the concentration of biomarker. The analytical performance of immunoassay system was evaluated by linearity and imprecision tests. The comparability of the FL immunoassay method was examined with a reference method.
RESULTS: FL intensities and the levels of myoglobin, CK-MB, and cTnI displayed good linearity and high correlations (r = 0.999, 0.998, and 0.989, respectively). The coefficient of variations (CVs) of imprecision for all cardiac biomarkers were less than 8% in both intra- and interassays. When the results from the developed method and bioMerieux VIDAS assay were analyzed by Bland-Altman plot and Passing-Bablok plot, the two assay methods were in good agreement.
CONCLUSION: The FL immunoassay system can provide a platform for point-of-care testing (POCT), and it is an easy, fast, and reliable method for the quantification of cardiac biomarkers.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  AMI; CK-MB; POCT; cTnI; fluorescence immunochromatographic assay; myoglobin

Mesh:

Substances:

Year:  2014        PMID: 24652617      PMCID: PMC6807338          DOI: 10.1002/jcla.21704

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  25 in total

1.  Cardiac troponin: a critical review of the case for point-of-care testing in the ED.

Authors:  Roland Bingisser; Charles Cairns; Michael Christ; Pierre Hausfater; Bertil Lindahl; Johannes Mair; Mauro Panteghini; Christopher Price; Per Venge
Journal:  Am J Emerg Med       Date:  2012-05-23       Impact factor: 2.469

Review 2.  Cardiac biomarkers and the case for point-of-care testing.

Authors:  Barry McDonnell; Stephen Hearty; Paul Leonard; Richard O'Kennedy
Journal:  Clin Biochem       Date:  2009-02-07       Impact factor: 3.281

3.  2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society.

Authors:  Andrew E Epstein; John P DiMarco; Kenneth A Ellenbogen; N A Mark Estes; Roger A Freedman; Leonard S Gettes; A Marc Gillinov; Gabriel Gregoratos; Stephen C Hammill; David L Hayes; Mark A Hlatky; L Kristin Newby; Richard L Page; Mark H Schoenfeld; Michael J Silka; Lynne Warner Stevenson; Michael O Sweeney
Journal:  Circulation       Date:  2012-12-19       Impact factor: 29.690

Review 4.  Analytical characteristics of high-sensitivity cardiac troponin assays.

Authors:  Fred S Apple; Paul O Collinson
Journal:  Clin Chem       Date:  2011-09-30       Impact factor: 8.327

5.  Approach to non-ST-segment elevation acute coronary syndrome in the emergency department: risk stratification and treatment strategies.

Authors:  Cedric W Lefebvre; James Hoekstra
Journal:  Hosp Pract (1995)       Date:  2010-04

Review 6.  Biomarkers in acute myocardial infarction.

Authors:  Daniel Chan; Leong L Ng
Journal:  BMC Med       Date:  2010-06-07       Impact factor: 8.775

7.  Value of myoglobin, troponin T, and CK-MBmass in ruling out an acute myocardial infarction in the emergency room.

Authors:  R J de Winter; R W Koster; A Sturk; G T Sanders
Journal:  Circulation       Date:  1995-12-15       Impact factor: 29.690

8.  Development of a point-of-care assay system for high-sensitivity C-reactive protein in whole blood.

Authors:  Jae Soon Ahn; Sunga Choi; Sang Ho Jang; Hyuk Jae Chang; Jae Hoon Kim; Ki Bong Nahm; Sang Wook Oh; Eui Yul Choi
Journal:  Clin Chim Acta       Date:  2003-06       Impact factor: 3.786

9.  Cardiac troponin I levels measured with a high-sensitive assay increase over time and are strong predictors of mortality in an elderly population.

Authors:  Kai M Eggers; Per Venge; Bertil Lindahl; Lars Lind
Journal:  J Am Coll Cardiol       Date:  2013-03-06       Impact factor: 24.094

10.  Differences between cardiac and skeletal troponin interaction with the thin filament probed by troponin exchange in skeletal myofibrils.

Authors:  Zhenyun Yang; Marie Yamazaki; Qingwu W Shen; Darl R Swartz
Journal:  Biophys J       Date:  2009-07-08       Impact factor: 4.033

View more
  5 in total

1.  A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB.

Authors:  Xiao-Hong Lai; Rong-Liang Liang; Tian-Cai Liu; Zhi-Ning Dong; Ying-Song Wu; Lin-Hai Li
Journal:  J Fluoresc       Date:  2016-04-01       Impact factor: 2.217

Review 2.  Point-of-care diagnostics for niche applications.

Authors:  Brian M Cummins; Frances S Ligler; Glenn M Walker
Journal:  Biotechnol Adv       Date:  2016-02-01       Impact factor: 14.227

3.  High performance immunochromatographic assay for simultaneous quantitative detection of multiplex cardiac markers based on magnetic nanobeads.

Authors:  Lixin Hong; Kan Wang; Wenqiang Yan; Hao Xu; Qinghui Chen; Yuhui Zhang; Daxiang Cui; Qinghui Jin; Jinghua He
Journal:  Theranostics       Date:  2018-11-29       Impact factor: 11.556

4.  Development of a Smartphone-Based Fluorescent Immunochromatographic Assay Strip Reader.

Authors:  Qi Zheng; Huihuang Wu; Haiyan Jiang; Jiejie Yang; Yueming Gao
Journal:  Sensors (Basel)       Date:  2020-08-13       Impact factor: 3.576

5.  Automatic Range Adjustment of the Fluorescence Immunochromatographic Assay Based on Image Processing.

Authors:  Ruixin Jiang; Huihuang Wu; Jianpeng Yang; Haiyan Jiang; Min Du; Mangi Vai; Siohang Pun; Yueming Gao
Journal:  Sensors (Basel)       Date:  2019-12-30       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.