Literature DB >> 24649137

A new optical probe for the detection of the sentinel lymph node using patent blue V dye in breast cancer: A preliminary study.

F Tellier1, P Poulet1, J P Ghnassia2, M Wilt2, D Weitbruch3, J F Rodier3.   

Abstract

The present study presents a novel near-infrared optical probe for the sentinel lymph node (SLN) detection in breast cancer patients, based on the recording of scattered photons. The aim of this study was to improve the detection of patent blue V (PBV), a dye routinely injected during clinical practice. A combined injection of the dye and radioactive colloid was used in the 24 patients enrolled in the study. The clinical results of the ex vivo detection of 70 dye-marked SLNs are reported, subsequent to the injection of various quantities of PBV (0.25-2 ml). The accuracy and success rate of an isotopic probe for the detection of radioactive colloid tracer, the eye visibility threshold of the surgeon and the use of a new optical probe were examined. The radio-labeled and dye-marked sentinel lymph nodes were all detected by the radio-isotopic probe, as opposed to the 75% detected by the eye visibility threshold of the surgeon. The optical probe detected all of the nodes, regardless of the volume of the dye injected. The relative PBV concentration computed by the probe facing SLNs with infravisible/visually undetectable dye-mark was relatively constant at 5.5±1.4 μmol/l. The optical detection of the sentinel lymph nodes using PBV and the probe presented in this study have the potential to reduce the false negative detection rate. This instrument is likely to provide surgeons with a simple diagnostic tool, without significantly changing their surgical procedures.

Entities:  

Keywords:  biomedical optics; breast cancer; metastasic nodes; optical probe; patent blue V dye; sentinel lymph node detection

Year:  2012        PMID: 24649137      PMCID: PMC3956239          DOI: 10.3892/mco.2012.26

Source DB:  PubMed          Journal:  Mol Clin Oncol        ISSN: 2049-9450


  16 in total

Review 1.  [Detection of the sentinel node by the surgeon].

Authors:  Jean-François Rodier
Journal:  Bull Cancer       Date:  2002-10       Impact factor: 1.276

Review 2.  Positron emission tomography (PET) for assessment of axillary lymph node status in early breast cancer: A systematic review and meta-analysis.

Authors:  K L Cooper; S Harnan; Y Meng; S E Ward; P Fitzgerald; D Papaioannou; L Wyld; C Ingram; I D Wilkinson; E Lorenz
Journal:  Eur J Surg Oncol       Date:  2011-01-26       Impact factor: 4.424

3.  Ultrasound of the axilla: where to look for the sentinel lymph node.

Authors:  P Britton; P Moyle; J R Benson; A Goud; R Sinnatamby; S Barter; M Gaskarth; E Provenzano; M Wallis
Journal:  Clin Radiol       Date:  2010-03-21       Impact factor: 2.350

4.  Estimation of optical pathlength through tissue from direct time of flight measurement.

Authors:  D T Delpy; M Cope; P van der Zee; S Arridge; S Wray; J Wyatt
Journal:  Phys Med Biol       Date:  1988-12       Impact factor: 3.609

5.  Physicochemical characteristics of patent blue violet dye.

Authors:  D W Newton; P J Breen; D E Brown; J F Mackie; R B Kluza
Journal:  J Pharm Sci       Date:  1981-02       Impact factor: 3.534

6.  Noninvasive photoacoustic and fluorescence sentinel lymph node identification using dye-loaded perfluorocarbon nanoparticles.

Authors:  Walter J Akers; Chulhong Kim; Mikhail Berezin; Kevin Guo; Ralph Fuhrhop; Gregory M Lanza; Georg M Fischer; Ewald Daltrozzo; Andreas Zumbusch; Xin Cai; Lihong V Wang; Samuel Achilefu
Journal:  ACS Nano       Date:  2010-12-20       Impact factor: 15.881

7.  Blue dye versus combined blue dye-radioactive tracer technique in detection of sentinel lymph node in breast cancer.

Authors:  Z Radovanovic; A Golubovic; A Plzak; B Stojiljkovic; D Radovanovic
Journal:  Eur J Surg Oncol       Date:  2004-11       Impact factor: 4.424

8.  Dynamic contrast enhanced MRI of the axilla in women with breast cancer: comparison with pathology of excised nodes.

Authors:  A D Murray; R T Staff; T W Redpath; F J Gilbert; A K Ah-See; J A Brookes; I D Miller; S Payne
Journal:  Br J Radiol       Date:  2002-03       Impact factor: 3.039

9.  Adverse reactions to patent blue V dye - The NEW START and ALMANAC experience.

Authors:  L Barthelmes; A Goyal; R G Newcombe; F McNeill; R E Mansel
Journal:  Eur J Surg Oncol       Date:  2009-11-24       Impact factor: 4.424

10.  Prospective multicentric randomized study comparing periareolar and peritumoral injection of radiotracer and blue dye for the detection of sentinel lymph node in breast sparing procedures: FRANSENODE trial.

Authors:  Jean-François Rodier; Michel Velten; Marc Wilt; Pierre Martel; Gwanaël Ferron; Véronique Vaini-Elies; Hervé Mignotte; Alain Brémond; Jean-Marc Classe; François Dravet; Thierry Routiot; Christine Tunon de Lara; Antoine Avril; Gérard Lorimier; Eric Fondrinier; Gilles Houvenaeghel; Sandrine Avigdor
Journal:  J Clin Oncol       Date:  2007-05-07       Impact factor: 44.544

View more
  1 in total

1.  Sentinel lymph nodes fluorescence detection and imaging using Patent Blue V bound to human serum albumin.

Authors:  Franklin Tellier; Jérôme Steibel; Renée Chabrier; François Xavier Blé; Hervé Tubaldo; Ravelo Rasata; Jacques Chambron; Guy Duportail; Hervé Simon; Jean-François Rodier; Patrick Poulet
Journal:  Biomed Opt Express       Date:  2012-08-30       Impact factor: 3.732

  1 in total