| Literature DB >> 24644401 |
Anshul Rai1, Shashwat Magarkar2, Abhay Datarkar3.
Abstract
For the correction of blow out fractures of the orbit, the retraction of orbital floor contents are necessary. We are here in presenting a customized orbital floor soft tissue retractor to overcome the disadvantages of the conventional Rows orbital floor retractor.Entities:
Keywords: Blow out fracture; Customized orbital floor soft tissue retractor; Orbital floor retraction; Rows orbital floor retractor; Spoon retractor
Year: 2012 PMID: 24644401 PMCID: PMC3955465 DOI: 10.1007/s12663-012-0389-z