Literature DB >> 23117309

Serial Evaluation of Vascular Response After Implantation of a New Sirolimus-Eluting Stent With Bioabsorbable Polymer (MISTENT): an optical coherence tomography and histopathological study.

Guilherme F Attizzani1, Hiram G Bezerra, Daniel Chamié, Yusuke Fujino, Anna-Maria Spognardi, James R L Stanley, Hirosada Yamamoto, Emile Mehanna, Wei Wang, Wenda C Carlyle, James B McClain, Marco A Costa.   

Abstract

BACKGROUND: Novel vascular scaffolds aim at equipoise between safety and efficacy. Intravascular optical coherence tomography (OCT) allows in-vivo serial assessment of stent-vessel interactions with high resolution and frequent sampling and may complement histology assessment. We investigated the vascular response to a novel absorbable coating sirolimus-eluting stent (AC-SES) by means of serial OCT and histology evaluation in a porcine model.
METHODS: One AC-SES and one bare-metal stent (BMS) were implanted in separate coronary arteries of three Yucatan mini-swine. Serial OCT was performed post procedure and at 3-, 28-, 90-, and 180-day follow-up. Normalized optical density (NOD) was used for the assessment of tissue response over time. Histological evaluation was performed at day 180.
RESULTS: A total of 6408 stent struts were analyzed. OCT revealed 100% of struts covered at 28 days, and a significant difference in NOD from 3 to 28 days (0.64 ± 0.07 vs 0.71 ± 0.05, respectively; P<.001) in the AC-SES group. Neointimal thickness was 0.14 ± 0.08 mm, 0.17 ± 0.11 mm, and 0.16 ± 0.09 mm in the AC-SES group and 0.18 ± 0.10 mm, 0.14 ± 0.09 mm, and 0.10 ± 0.08 mm in the BMS group, while rates of uncovered struts were 0%, 0%, and 3.1% and 1.4%, 7.8%, and 21.5%, respectively, at 28, 90, and 180 days. Minimal inflammation and a mature endothelialization were demonstrated in both groups by histology.
CONCLUSION: OCT serial assessment of vascular response suggested NIH maturation 28 days following AC-SES implantation in pigs. These findings, coupled with histological demonstration of low inflammation scores and complete endothelial coverage as measured at 180 days, suggest a satisfactory healing response to AC-SES.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23117309

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  6 in total

1.  Intra-coronary imaging modalities.

Authors:  Paul M Johnson; Jigar Patel; Michael Yeung; Prashant Kaul
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-05

2.  Assessment of the healing process after percutaneous implantation of a cardiovascular device: a systematic review.

Authors:  Elodie Perdreau; Zakaria Jalal; Richard D Walton; Jérôme Naulin; Julie Magat; Bruno Quesson; Hubert Cochet; Olivier Bernus; Jean-Benoît Thambo
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-19       Impact factor: 2.357

3.  Neointimal tissue characterization after implantation of drug-eluting stents by optical coherence tomography: quantitative analysis of optical density.

Authors:  Setsu Nishino; Masashi Sakuma; Tomoaki Kanaya; Takahisa Nasuno; Michiaki Tokura; Shigeru Toyoda; Shichiro Abe; Daisuke Nakamura; Kentaro Tanaka; Guiherme F Attizzani; Hiram G Bezerra; Marco A Costa; Teruo Inoue
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-19       Impact factor: 2.357

4.  Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

Authors:  Alexandra J Lansky; Adnan Kastrati; Elazer R Edelman; Helen Parise; Vivian G Ng; John Ormiston; William Wijns; Robert A Byrne
Journal:  Am J Cardiol       Date:  2015-12-07       Impact factor: 2.778

Review 5.  Research and clinical applications of optical coherence tomography in invasive cardiology: a review.

Authors:  Luigi Vignali; Emilia Solinas; Enzo Emanuele
Journal:  Curr Cardiol Rev       Date:  2014-11

6.  Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study.

Authors:  William Wijns; Junya Shite; Michael R Jones; Stephen W L Lee; Matthew J Price; Franco Fabbiocchi; Emanuele Barbato; Takashi Akasaka; Hiram Bezerra; David Holmes
Journal:  Eur Heart J       Date:  2015-08-04       Impact factor: 29.983

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.