Literature DB >> 24641915

Improving signal to noise in labeled biological specimens using energy-filtered TEM of sections with a drift correction strategy and a direct detection device.

Ranjan Ramachandra1, James C Bouwer1, Mason R Mackey1, Eric Bushong1, Steven T Peltier1, Nguyen-Huu Xuong1, Mark H Ellisman1.   

Abstract

Energy filtered transmission electron microscopy techniques are regularly used to build elemental maps of spatially distributed nanoparticles in materials and biological specimens. When working with thick biological sections, electron energy loss spectroscopy techniques involving core-loss electrons often require exposures exceeding several minutes to provide sufficient signal to noise. Image quality with these long exposures is often compromised by specimen drift, which results in blurring and reduced resolution. To mitigate drift artifacts, a series of short exposure images can be acquired, aligned, and merged to form a single image. For samples where the target elements have extremely low signal yields, the use of charge coupled device (CCD)-based detectors for this purpose can be problematic. At short acquisition times, the images produced by CCDs can be noisy and may contain fixed pattern artifacts that impact subsequent correlative alignment. Here we report on the use of direct electron detection devices (DDD's) to increase the signal to noise as compared with CCD's. A 3× improvement in signal is reported with a DDD versus a comparably formatted CCD, with equivalent dose on each detector. With the fast rolling-readout design of the DDD, the duty cycle provides a major benefit, as there is no dead time between successive frames.

Entities:  

Mesh:

Year:  2014        PMID: 24641915      PMCID: PMC4178974          DOI: 10.1017/S1431927614000452

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  25 in total

Review 1.  Digital imaging in transmission electron microscopy.

Authors:  G Y Fan; M H Ellisman
Journal:  J Microsc       Date:  2000-10       Impact factor: 1.758

2.  Detecting single atoms of calcium and iron in biological structures by electron energy-loss spectrum-imaging.

Authors:  R D Leapman
Journal:  J Microsc       Date:  2003-04       Impact factor: 1.758

3.  Optimization of EFTEM image acquisition by using elastically filtered images for drift correction.

Authors:  Tobias Heil; Helmut Kohl
Journal:  Ultramicroscopy       Date:  2010-03-31       Impact factor: 2.689

4.  Electron tomography of degenerating neurons in mice with abnormal regulation of iron metabolism.

Authors:  Peijun Zhang; William Land; Stanton Lee; Jemma Juliani; Jonathan Lefman; Sophia R Smith; David Germain; Martin Kessel; Richard Leapman; Tracey A Rouault; Sriram Subramaniam
Journal:  J Struct Biol       Date:  2005-05       Impact factor: 2.867

5.  Future directions for camera systems in electron microscopy.

Authors:  Nguyen-Huu Xuong; Liang Jin; Stuart Kleinfelder; Shengdong Li; Philippe Leblanc; Fred Duttweiler; James C Bouwer; Steven T Peltier; Anna-Clare Milazzo; Mark Ellisman
Journal:  Methods Cell Biol       Date:  2007       Impact factor: 1.441

6.  Achieving sub-nanometre particle mapping with energy-filtered TEM.

Authors:  S Lozano-Perez; V de Castro Bernal; R J Nicholls
Journal:  Ultramicroscopy       Date:  2009-05-19       Impact factor: 2.689

7.  Protoplasmic astrocytes in CA1 stratum radiatum occupy separate anatomical domains.

Authors:  Eric A Bushong; Maryann E Martone; Ying Z Jones; Mark H Ellisman
Journal:  J Neurosci       Date:  2002-01-01       Impact factor: 6.167

8.  Optimizing EELS acquisition.

Authors:  Michel Bosman; Vicki J Keast
Journal:  Ultramicroscopy       Date:  2008-03-10       Impact factor: 2.689

9.  High-sensitivity lens-coupled slow-scan CCD camera for transmission electron microscopy.

Authors:  G Y Fan; M H Ellisman
Journal:  Ultramicroscopy       Date:  1993-09       Impact factor: 2.689

10.  Quantitative EFTEM mapping of near physiological calcium concentrations in biological specimens.

Authors:  M A Aronova; Y C Kim; N B Pivovarova; S B Andrews; R D Leapman
Journal:  Ultramicroscopy       Date:  2008-11-01       Impact factor: 2.689

View more
  5 in total

1.  Split-miniSOG for Spatially Detecting Intracellular Protein-Protein Interactions by Correlated Light and Electron Microscopy.

Authors:  Daniela Boassa; Sakina P Lemieux; Varda Lev-Ram; Junru Hu; Qing Xiong; Sebastien Phan; Mason Mackey; Ranjan Ramachandra; Ryan Emily Peace; Stephen R Adams; Mark H Ellisman; John T Ngo
Journal:  Cell Chem Biol       Date:  2019-08-01       Impact factor: 8.116

2.  Sub-mitochondrial localization of the genetic-tagged mitochondrial intermembrane space-bridging components Mic19, Mic60 and Sam50.

Authors:  Mira Sastri; Manjula Darshi; Mason Mackey; Ranjan Ramachandra; Saeyeon Ju; Sebastien Phan; Stephen Adams; Kathryn Stein; Christopher R Douglas; Jiwan John Kim; Mark H Ellisman; Susan S Taylor; Guy A Perkins
Journal:  J Cell Sci       Date:  2017-08-14       Impact factor: 5.285

Review 3.  Resolving presynaptic structure by electron tomography.

Authors:  Guy A Perkins; Dakota R Jackson; George A Spirou
Journal:  Synapse       Date:  2015-03-09       Impact factor: 2.562

Review 4.  ColorEM: analytical electron microscopy for element-guided identification and imaging of the building blocks of life.

Authors:  Nicole M Pirozzi; Jacob P Hoogenboom; Ben N G Giepmans
Journal:  Histochem Cell Biol       Date:  2018-08-17       Impact factor: 4.304

5.  Elemental mapping of labelled biological specimens at intermediate energy loss in an energy-filtered TEM acquired using a direct detection device.

Authors:  Ranjan Ramachandra; Mason R Mackey; Junru Hu; Steven T Peltier; Nguyen-Huu Xuong; Mark H Ellisman; Stephen R Adams
Journal:  J Microsc       Date:  2021-05-03       Impact factor: 1.758

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.