Literature DB >> 24641349

Computed tomography-based joint locations affect calculation of joint moments during gait when compared to scaling approaches.

Ward Bartels1, Jan Demol, Frederik Gelaude, Ilse Jonkers, Jos Vander Sloten.   

Abstract

Hip joint moments are an important parameter in the biomechanical evaluation of orthopaedic surgery. Joint moments are generally calculated using scaled generic musculoskeletal models. However, due to anatomical variability or pathology, such models may differ from the patient's anatomy, calling into question the accuracy of the resulting joint moments. This study aimed to quantify the potential joint moment errors caused by geometrical inaccuracies in scaled models, during gait, for eight test subjects. For comparison, a semi-automatic computed tomography (CT)-based workflow was introduced to create models with subject-specific joint locations and inertial parameters. 3D surface models of the femora and hemipelves were created by segmentation and the hip joint centres and knee axes were located in these models. The scaled models systematically located the hip joint centre (HJC) up to 33.6 mm too inferiorly. As a consequence, significant and substantial peak hip extension and abduction moment differences were recorded, with, respectively, up to 23.1% and 15.8% higher values in the image-based models. These findings reaffirm the importance of accurate HJC estimation, which may be achieved using CT- or radiography-based subject-specific modelling. However, obesity-related gait analysis marker placement errors may have influenced these results and more research is needed to overcome these artefacts.

Entities:  

Keywords:  computed tomography; gait analysis; joint moments; musculoskeletal modelling; subject-specific

Year:  2014        PMID: 24641349     DOI: 10.1080/10255842.2014.890186

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  5 in total

1.  Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model.

Authors:  Aimad El Habachi; Florent Moissenet; Sonia Duprey; Laurence Cheze; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2015-03-18       Impact factor: 2.602

Review 2.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

3.  In-vivo quantification of dynamic hip joint center errors and soft tissue artifact.

Authors:  Niccolo M Fiorentino; Penny R Atkins; Michael J Kutschke; K Bo Foreman; Andrew E Anderson
Journal:  Gait Posture       Date:  2016-09-11       Impact factor: 2.840

Review 4.  Advancing quantitative techniques to improve understanding of the skeletal structure-function relationship.

Authors:  Frances T Sheehan; Elizabeth L Brainerd; Karen L Troy; Sandra J Shefelbine; Janet L Ronsky
Journal:  J Neuroeng Rehabil       Date:  2018-03-20       Impact factor: 4.262

5.  A robust method for automatic identification of landmarks on surface models of the pelvis.

Authors:  Maximilian C M Fischer; Felix Krooß; Juliana Habor; Klaus Radermacher
Journal:  Sci Rep       Date:  2019-09-16       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.