Literature DB >> 24633421

Systematic survey of the dose enhancement in tissue-equivalent materials facing medium- and high-Z backscatterers exposed to X-rays with energies from 5 to 250 keV.

M Seidenbusch1, D Harder, D Regulla.   

Abstract

The present study has been inspired by the results of earlier dose measurements in tissue-equivalent materials adjacent to thin foils of aluminum, copper, tin, gold, and lead. Large dose enhancements have been observed in low-Z materials near the interface when this ensemble was irradiated with X-rays of qualities known from diagnostic radiology. The excess doses have been attributed to photo-, Compton, and Auger electrons released from the metal surfaces. Correspondingly, high enhancements of biological effects have been observed in single cell layers arranged close to gold surfaces. The objective of the present work is to systematically survey, by calculation, the values of the dose enhancement in low-Z media facing backscattering materials with a variety of atomic numbers and over a large range of photon energies. Further parameters to be varied are the distance of the point of interest from the interface and the kind of the low-Z material. The voluminous calculations have been performed using the PHOTCOEF algorithm, a proven set of interpolation functions fitted to long-established Monte Carlo results, for primary photon energies between 5 and 250 keV and for atomic numbers varying over the periodic system up to Z = 100. The calculated results correlate well with our previous experimental results. It is shown that the values of the dose enhancement (a) vary strongly in dependence upon Z and photon energy; (b) have maxima in the energy region from 40 to 60 keV, determined by the K and L edges of the backscattering materials; and (c) are valued up to about 130 for "International Commission on Radiological Protection (ICRP) soft tissue" (soft tissue composition recommended by the ICRP) as the adjacent low-Z material. Maximum dose enhancement associated with the L edge occurs for materials with atomic numbers between 50 and 60, e.g., barium (Z = 56) and iodine (Z = 53). Such materials typically serve as contrast media in medical X-ray diagnostics. The gradual reduction in the dose enhancement with increasing distance from the material interface, owed to the limited ranges of the emitted secondary electrons, has been documented in detail. The discussion is devoted to practical radiological aspects of the dose enhancement phenomenon. Cytogenetic effects in cell layers closely proximate to surfaces of medium-Z materials might vary over two orders of magnitude, because the dose enhancement is accompanied by the earlier observed about twofold increase in the low-dose RBEM at a tissue-to-gold interface.

Entities:  

Mesh:

Year:  2014        PMID: 24633421     DOI: 10.1007/s00411-014-0524-y

Source DB:  PubMed          Journal:  Radiat Environ Biophys        ISSN: 0301-634X            Impact factor:   1.925


  40 in total

1.  Dose distributions using kilovoltage x-rays and dose enhancement from iodine contrast agents.

Authors:  A V Mesa; A Norman; T D Solberg; J J Demarco; J B Smathers
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

2.  [Dosimetric perturbation due to scattered rays released by a gold marker used for tumor tracking in external radiotherapy].

Authors:  Kosaku Habara; Tomohiro Shimozato; Yuichi Aoyama; Naoki Hayashi; Keisuke Yasui; Kanji Matsuura; Takashi Furukawa; Ryota Kawanami; Yasunori Obata
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2011

3.  Determining the size and shape dependence of gold nanoparticle uptake into mammalian cells.

Authors:  B Devika Chithrani; Arezou A Ghazani; Warren C W Chan
Journal:  Nano Lett       Date:  2006-04       Impact factor: 11.189

4.  Dosimetric measurement of scattered radiation from dental implants in simulated head and neck radiotherapy.

Authors:  R Wang; K Pillai; P K Jones
Journal:  Int J Oral Maxillofac Implants       Date:  1998 Mar-Apr       Impact factor: 2.804

5.  Effect of radiation and contrast media on chromosomes. Preliminary report.

Authors:  F H Adams; A Norman; R S Mello; D Bass
Journal:  Radiology       Date:  1977-09       Impact factor: 11.105

6.  Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities.

Authors:  S A M Lloyd; W Ansbacher
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

7.  Backscatter dose perturbation in kilovoltage photon beams at high atomic number interfaces.

Authors:  I J Das; K L Chopra
Journal:  Med Phys       Date:  1995-06       Impact factor: 4.071

8.  The use of gold nanoparticles to enhance radiotherapy in mice.

Authors:  James F Hainfeld; Daniel N Slatkin; Henry M Smilowitz
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

9.  Backscatter radiation at tissue-titanium interfaces. Biological effects from diagnostic 65 kVp x-rays.

Authors:  B Rosengren; L Wulff; E Carlsson; J Carlsson; K G Strid; A Montelius
Journal:  Acta Oncol       Date:  1993       Impact factor: 4.089

10.  Osseointegrated implants for prosthetic rehabilitation after treatment of cancer of the oral cavity.

Authors:  P Marker; S J Siemssen; L Bastholt
Journal:  Acta Oncol       Date:  1997       Impact factor: 4.089

View more
  2 in total

Review 1.  Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays.

Authors:  Piotr Zygmanski; Erno Sajo
Journal:  Br J Radiol       Date:  2015-12-07       Impact factor: 3.039

2.  Thin-film CdTe detector for microdosimetric study of radiation dose enhancement at gold-tissue interface.

Authors:  Nava Raj Paudel; Diana Shvydka; E Ishmael Parsai
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.