Literature DB >> 24632132

A multiplex assay based on encoded microbeads conjugated to DNA NanoBeacons to monitor base excision repair activities by flow cytometry.

Guillaume Gines1, Christine Saint-Pierre1, Didier Gasparutto2.   

Abstract

We reported here a new assay to detect base excision repair activities from purified enzymes, as well as in cell-free extracts. The multiplex format rests upon the encoding of magnetic beads with the fluorophore Alexa 488, thanks to a fast and original procedure. Fluorescently encoded microbeads are subsequently functionalized by lesion-containing DNA NanoBeacons labeled with the fluorophore/quencher pair Cyanine 5/BHQ2. Probes cleavage, induced by targeted enzymes leads to Cyanine 5 signal enhancement, which is finally quantified by flow cytometry. The multiplex assay was applied to the detection of restriction enzymes activities as well as base excision repair processes. Each test requires only 500fmol of DNA substrate, which constitutes great sensitivity compared to other BER functional assays. The present biosensor is able to detect both uracil DNA N-glycosylase (UNG) and AP-endonuclease 1 (APE1) within few nanograms of nuclear extract. Additionally, we demonstrated that the corresponding assay has potential application in DNA repair inhibitor search. Finally, the current multiplexed tool shows several advantages in comparison to other functional BER assays with no need of electrophoretic separation, straightforward, easy and reproducible functionalization of encoded microbeads and a high stability of DNA probes in cell-free extracts.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Base excision repair; DNA nanoprobes; Encoded microbeads; Flow cytometry; Fluorescence-based biosensor; Multiplex assay

Mesh:

Substances:

Year:  2014        PMID: 24632132     DOI: 10.1016/j.bios.2014.02.040

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Fluorescent Probes of DNA Repair.

Authors:  David L Wilson; Eric T Kool
Journal:  ACS Chem Biol       Date:  2017-11-30       Impact factor: 5.100

2.  Signal-on/signal-off bead-based assays for the multiplexed monitoring of base excision repair activities by flow cytometry.

Authors:  Guillaume Gines; Charlotte Brusa; Christine Saint-Pierre; Didier Gasparutto
Journal:  Anal Bioanal Chem       Date:  2022-01-23       Impact factor: 4.142

3.  Base excision-initiated terminal deoxynucleotide transferase-assisted amplification for simultaneous detection of multiple DNA glycosylases.

Authors:  Yue Sun; Liu Zang; Jianzhong Lu
Journal:  Anal Bioanal Chem       Date:  2022-03-12       Impact factor: 4.478

Review 4.  Inhibitors of DNA Glycosylases as Prospective Drugs.

Authors:  Grigory V Mechetin; Anton V Endutkin; Evgeniia A Diatlova; Dmitry O Zharkov
Journal:  Int J Mol Sci       Date:  2020-04-28       Impact factor: 5.923

  4 in total