Literature DB >> 24630397

Use of polyetheretherketone in the fabrication of a maxillary obturator prosthesis: a clinical report.

Santiago Costa-Palau1, Josep Torrents-Nicolas2, Magi Brufau-de Barberà3, Josep Cabratosa-Termes4.   

Abstract

To treat a patient who needed a replacement for a maxillary obturator prosthesis, a new obturator prosthesis was fabricated from polyetheretherketone (PEEK), a material often used in medicine but seldom in dentistry. This material provided the patient with a better-adjusted, more functional, and lighter prosthesis.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24630397     DOI: 10.1016/j.prosdent.2013.10.026

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  11 in total

1.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

2.  Comparative prospective clinical evaluation of computer aided design/ computer aided manufacturing milled BioHPP PEEK inlays and Zirconia inlays.

Authors:  Vijaya Kumar Rajamani; Sandeep Singh Reyal; Eraiah Mahesh Gowda; Muttige Parameshwara Shashidhar
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

Review 3.  Barrier Membrane in Regenerative Therapy: A Narrative Review.

Authors:  Muhammad Syafiq Alauddin; Nur Ayman Abdul Hayei; Muhammad Annurdin Sabarudin; Nor Haliza Mat Baharin
Journal:  Membranes (Basel)       Date:  2022-04-20

4.  Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

Authors:  Yoshifumi Tada; Tohru Hayakawa; Yoshiki Nakamura
Journal:  Materials (Basel)       Date:  2017-08-09       Impact factor: 3.623

5.  Effect of the Composition of CAD/CAM Composite Blocks on Mechanical Properties.

Authors:  Rasha A Alamoush; Nick Silikas; Nesreen A Salim; Suhad Al-Nasrawi; Julian D Satterthwaite
Journal:  Biomed Res Int       Date:  2018-10-23       Impact factor: 3.411

Review 6.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

7.  Assessment of different surface treatments and shear bond characteristics of poly-ether-ether-ketone: An in vitro SEM analysis.

Authors:  Umair Parkar; Ramandeep Dugal; Pallavi Madanshetty; Trupti Devadiga; Abid Sharifullah Khan; Aamir Godil
Journal:  J Indian Prosthodont Soc       Date:  2021 Oct-Dec

8.  Evaluation of the Grafting Efficacy of Active Biomolecules of Phosphatidylcholine and Type I Collagen on Polyether Ether Ketone: In Vitro and In Vivo.

Authors:  Jian-Chih Chen; Chih-Hua Chen; Kai-Chi Chang; Shih-Ming Liu; Chia-Ling Ko; Chi-Jen Shih; Ying-Sui Sun; Wen-Cheng Chen
Journal:  Polymers (Basel)       Date:  2021-06-24       Impact factor: 4.329

Review 9.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

10.  Stress distribution on different bar materials in implant-retained palatal obturator.

Authors:  Regina Furbino Villefort; João Paulo Mendes Tribst; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Borges; Nívia Castro Binda; Carlos Eduardo de Almeida Ferreira; Marco Antonio Bottino; Sandra Lúcia Ventorim von Zeidler
Journal:  PLoS One       Date:  2020-10-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.