Literature DB >> 24625536

A novel rotary pulsatile flow pump for cardiopulmonary bypass.

Nicholas R Teman1, Daniel E Mazur, John Toomasian, Emilia Jahangir, Fares Alghanem, Marcus Goudie, Alvaro Rojas-Peña, Jonathan W Haft.   

Abstract

It has been suggested that pulsatile blood flow is superior to continuous flow (CF) in cardiopulmonary bypass (CPB). However, adoption of pulsatile flow (PF) technology has been limited because of practicality and complexity of creating a consistent physiologic pulse. A pediatric pulsatile rotary ventricular pump (PRVP) was designed to address this problem. We evaluated the PRVP in an animal model and determined its ability to generate PF during CPB. The PRVP (modified peristaltic pump, with tapering of the outlet of the pump chamber) was tested in four piglets (10-12 kg). Cannulation was performed with right atrial and aortic cannulae, and pressure sensors were inserted into the femoral arteries. Pressure curves were obtained at different levels of flow and compared with both the animal's baseline physiologic function and a CF roller pump. Pressure and flow waveforms demonstrated significant pulsatility in the PRVP setup compared with CF at all tested conditions. Measurement of hemodynamic energy data, including the percentage pulsatile energy and the surplus hydraulic energy, also revealed a significant increase in pulsatility with the PRVP (p < 0.001). The PRVP creates physiologically significant PF, similar to the pulsatility of a native heart, and has the potential to be easily implemented in pediatric CPB.

Entities:  

Mesh:

Year:  2014        PMID: 24625536      PMCID: PMC4070378          DOI: 10.1097/MAT.0000000000000058

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  34 in total

1.  Pediatric physiologic pulsatile pump enhances cerebral and renal blood flow during and after cardiopulmonary bypass.

Authors:  Akif Undar; Takafumi Masai; Erik A Beyer; Jan Goddard-Finegold; Mary Claire McGarry; Charles D Fraser
Journal:  Artif Organs       Date:  2002-11       Impact factor: 3.094

2.  Significant safety advantages gained with an improved pressure-regulated blood pump.

Authors:  J P Montoya; S I Merz; R H Bartlett
Journal:  J Extra Corpor Technol       Date:  1996-06

3.  Centrifugal pump inlet pressure site affects measurement.

Authors:  Simon Augustin; Alison Horton; Warwick Butt; Martin Bennett; Stephen Horton
Journal:  Perfusion       Date:  2010-07-14       Impact factor: 1.972

4.  Pulsatile flow improves cerebral blood flow in pediatric cardiopulmonary bypass.

Authors:  Wei Wang; Shu-Ying Bai; Hai-Bo Zhang; Jie Bai; Shu-Jing Zhang; De-Ming Zhu
Journal:  Artif Organs       Date:  2010-11       Impact factor: 3.094

5.  Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support.

Authors:  Akif Undar; Gerson Rosenberg; John L Myers
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

6.  Comparison of pumps and oxygenators with pulsatile and nonpulsatile modes in an infant cardiopulmonary bypass model.

Authors:  Nikkole M Haines; Shigang Wang; Allen Kunselman; John L Myers; Akif Undar
Journal:  Artif Organs       Date:  2009-11       Impact factor: 3.094

7.  Cytokine and endothelial damage in pulsatile and nonpulsatile cardiopulmonary bypass.

Authors:  Y Orime; M Shiono; H Hata; S Yagi; S Tsukamoto; H Okumura; K Nakata; S Kimura; M Hata; A Sezai; Y Sezai
Journal:  Artif Organs       Date:  1999-06       Impact factor: 3.094

8.  Energy equivalent pressure.

Authors:  R B Shepard; D C Simpson; J F Sharp
Journal:  Arch Surg       Date:  1966-11

9.  A novel, low cost, disposable, pediatric pulsatile rotary ventricular pump for cardiac surgery that provides a physiological flow pattern.

Authors:  Daniel E Mazur; Kathryn R Osterholzer; John M Toomasian; Scott I Merz
Journal:  ASAIO J       Date:  2008 Sep-Oct       Impact factor: 2.872

10.  A hemodynamic evaluation of the Levitronix Pedivas centrifugal pump and Jostra Hl-20 roller pump under pulsatile and nonpulsatile perfusion in an infant CPB model.

Authors:  Noel Ressler; Alan R Rider; Allen R Kunselman; J Scott Richardson; Kurt A Dasse; Shigang Wang; Akif Undar
Journal:  ASAIO J       Date:  2009 Jan-Feb       Impact factor: 2.872

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.